SystemBase eCAN User Manual Download Page 14

 

 

eCAN

 User Manual     

 

                         

 

 

13 

 

(2) Web Connection

 

Open a web browser and enter the IP address of the eCAN. Then the authentication window appears on the first connection. 
Default ID is “ecan”, password is “99999999(eight nines)”. After login, the web settings page appears. 

 

eCAN Initial IP Address: 192.168.0.223

 

User name: ecan

 

Password: 99999999 

 

 

Summary of Contents for eCAN

Page 1: ...User Manual www sysbas com eCAN Version 1 0 2021 07 02...

Page 2: ...1 Revision History Revision Date Document Ver Pages Revised Revised Added Removed Details of Revision 2021 07 02 1 0 All New...

Page 3: ...NENTS 5 3 PRODUCT 6 4 FEATURES 5 HOW TO USE 9 6 HOW TO SETUP 10 7 SETTING EXAMPLES 21 1 SPECIFICATION 23 2 DIMENSION 25 3 CAN PORT PIN SPECIFICATION 26 4 SETTING MENU 27 5 ECAN FRAME STRUCTURE 30 6 EC...

Page 4: ...stions and answers please visit our website and find Support Technical Support FAQ section Documents can be downloaded from the product page or Download section Sellers or users should be aware of the...

Page 5: ...e message which is except it needs 2 Enhanced Error Mechanism Several mechanisms have applied to CAN to improve communication reliability If communication state detection error check and management we...

Page 6: ...eCAN User Manual 5 2 Components Components Ordering Information eCAN 5V DC Adaptor LAN Cable Warranty Download Guide eCAN...

Page 7: ...N Port CAN Port Male LED LED State Operation 1 RDY Ready Blink Blinks when power is applied and boots normally 2 DATA Data Blink LED blinks when sending receiving data 3 LNK Link On Off Blink Lights w...

Page 8: ...ore than 3 seconds Factory initialize equipment Please refer to the APPENDIX for initialization values Switch ON 1 2 3 4 Switch Number Status Operation 1 Switch1 4 Not used 2 Switch2 3 Must be used at...

Page 9: ...cket communication which the network communication is able 2 CAN VBUS Power Supply Feature In addition to the 5V Power supply through DC adapter eCAN can be also powered by pin no 9 of the CAN port 3...

Page 10: ...twork Users can check CAN data on PC over the network or generate CAN data and forward it to CAN Bus Connection between CAN equipment CAN Bus To enable communication between different CAN Buses set tw...

Page 11: ...r more information To view or setup your eCAN environment you should use eCANConfig utility or use the WebPage to connect to the IP Address the network address on which the eCAN is operating Setting t...

Page 12: ...eCAN User Manual 11 3 Click Internet protocol version TCP IPv4 and then click Properties...

Page 13: ...eCAN User Manual 12 4 Click Use IP Address S and enter IP address 5 Enter the IP address and subnet mask address and click OK...

Page 14: ...enter the IP address of the eCAN Then the authentication window appears on the first connection Default ID is ecan password is 99999999 eight nines After login the web settings page appears eCAN Initi...

Page 15: ...herefore if you change the settings using the web you should connect the integrated device to the 100Mbps network environment or PC as below If it is difficult to configure the environment below you c...

Page 16: ...he Network Setting After changing the settings you must press the Submit button to save the changed value and restart it through the Reboot menu to apply it to the actual equipment operation If you ex...

Page 17: ...e changed value and restart it through the Reboot menu to apply it to the actual equipment operation If you exit without saving the changes the changed value will be lost If you have not saved the cha...

Page 18: ...received Set the SW Filter value for CAN ports in Filter Setting You can set the ID and Properties to filter by electing the filter number in the combo box at the bottom of the setting page After chan...

Page 19: ...s setting will be applied simultaneously with saving without rebooting If you forget your ID and password you can reset it to the default ID and password by pressing the RST button for more than 3 sec...

Page 20: ...a local network you can search directly by IP address When you click Search IP button the Search by IP window appears where you can enter the IP address directly to search for 3 Configure You can cha...

Page 21: ...set the Device Name IP Address Subnet Mask and Gateway in the searched Device List If you click Apply after changing it applies to each device that has changed its settings However if the network inf...

Page 22: ...ting Access to COMx port using COM Redirector access to 192 168 0 200 4001 Operation Mode COM Redirector Local Port 4001 TCP Server Local Port 4001 Operation Mode TCP Client Target IP 192 168 0 100 Ta...

Page 23: ...peration Mode TCP Server Local Port 4001 Operation Mode TCP Client Target IP 192 168 0 100 Target Port 4001 Operation Mode TCP Client Target IP 192 168 0 200 Target Port 4001 Operation Mode TCP Server...

Page 24: ...A B Signals CAN_H CAN_L Hardware Power 5V 1A DC Input Power consumption 0 95W Power Connector DC Type Outer 3 5mm Internal 1 35mm Dimension W x L x H 40 9 x 74 5 x 16 5mm 1 61 x 2 93 x 0 65in Weight...

Page 25: ...eCAN User Manual 24 Software Protocol TCP UDP ICMP DHCP HTTP Operation Mode COM Redirector TCP Server Client UDP Server Client Utility COM Redirector Configuration Web eCANConfig...

Page 26: ...eCAN User Manual 25 2 Dimension...

Page 27: ...eCAN User Manual 26 3 CAN Port Pin Specification CAN DB9 Male Pin No Signal Description 2 CAN_L CAN Low Signal 6 GND Ground 7 CAN_H CAN High Signal 9 VCC 5VDC Power...

Page 28: ...ts the Static IP address of the equipment If Connection Type is Static IP enter the IP address directly If it is DHCP it is unchangeable Subnet mask 255 255 255 0 Sets the subnet mask address of the e...

Page 29: ...uest access to are set at Target IP Target Port UDP Server The eCAN acts as a UDP server and waits for UDP connections from the client on the network The socket number to open is set in Local Port UDP...

Page 30: ...o the delay between Ethernet transmission and CAN transmission get minimized However it is disadvantageous for high speed and packet wise data transmission Baudrate 125 kbps Set the communication spee...

Page 31: ...sists of TYPE ID DLC DATA eCAN Error Frame The total length of the eCAN Error Frame is 14bytes and consists of TYPE Status REC TEC LEC When Request it request 14bytes including Type 0xFF Ex FF 00 00 0...

Page 32: ...ror counter If CAN message received successfully REC REC 1 When the receiver detects an error and sends the Error Flag REC REC 1 When the receiver first detects an error and sends the Error Flag REC R...

Page 33: ...ed message and the inspected value do not match The table below summarizes the explanation above TYPE Status REC TEC LEC 1Byte 1Byte 1Byte 1Byte 1Byte VCP Mode Frames in VCP Mode are configured differ...

Page 34: ...r Info eCAN Error Frame Set DLC to 0x30 0x38 0 8 ASCII 1byte DATA consists of 0 16bytes and converts each 1byte HEX value of the data to be transmitted into 2bytes of ASCII code 1byte to send 0x31 0x3...

Page 35: ...hen transmitter detects an error and send the Error Flag TEX TEC 8 LEC It is Last Error Code displaying the last error Value Description 0x3030 No Error 0x3031 Stuff Error occurs when a message contai...

Page 36: ...of CAN Frame Data Specifies the CAN Frame Data to Hex value TX Count Counts CAN frames sent from eCANView to eCAN RX Count Counts CAN frames sent from eCAN to eCANView Interval Sets the auto transmis...

Page 37: ...eCAN User Manual 36 Action You can select either the Connect menu or the Disconnect menu Connect Depending on the operating mode of the eCAN you can specify a VCP TCP Server Client UDP connection...

Page 38: ...TCP Server 192 168 0 226 4001 250kbps set Spec B and reboot 2 Connect the CAN ports of eCAN1 and eCAN2 through the cable 3 Run eCANView 4 Select the Action Connect menu 5 Select the Network tab specif...

Page 39: ...eCAN User Manual 38 7 To connect eCAN2 perform steps 3 6 again with the address of eCAN2 8 Configure the CAN Frame in the eCANView connected with eCAN1 and press the Send button...

Page 40: ...shows 100 000 communication data If there are more than 100 000 data the screen will clear and display again You can save communication data on the screen through Log Save in the menu If communication...

Page 41: ...017 EN 61000 3 2 2014 EN 61000 3 3 2013 8 Copyright Copyright 2021 SystemBase Co Ltd All rights reserved This manual is a document protected by Copyright law Unauthorized copying duplicating publishin...

Page 42: ...ation overseas sysbas com Technical Support RMA tech sysbas com www sysbas com Tel 82 2 855 0501 Fax 82 2 855 0580 If you have any inconvenience while using the product please contact us Working Hour...

Reviews: