background image

REMOTE MANAGEMENT

The C510ip-s Codec can be configured remotely by 
connecting a straight 9 Way D-Type cable to the 
MGR IP port, and using the Standard Windows 
Terminal Program. To configure more than one unit 
at the same time, the user can connect another 
straight 9 Way D-Type cable from the MGR OP port 
of the first unit, to the MGR IP port of the next unit, 
in a “Daisy Chain” manner. There are no limitations 
on the number of codecs which can be linked 
together for remote configuration purposes.

On initial connection, the Standard Windows 
Terminal Program screen will be blank. The user 
should then press the Enter key to clear the 
command buffer.

Type “poll” followed by the serial number :-

poll 0108-001 < carriage return / enter >
0108-001>

A prompt of the actual serial number will appear on 
the screen.

Type “help” for list of commands. 

0108-001 >help

C510ip-s Network Commands, (c) Systembase Limited

poll (8 digit serial number)
status (displays the codecs current status, /s option for 
short)
set name (new patch name)
set patch (patch index)
set backup level (0..100)
set restore time (1..90)
set reserve (Off, On)
set aux (Off, 

9600bps,
4800bps,
2400bps,  
9600bps(alt), 
4800bps(alt), 
2400bps(alt), 
Relay Mode)

set source (Analog, AES3)
set loopback (Off, On)
set x21 (APTX:3K7 Stereo 64Kbps,
         

APTX:7K5 Mono 64Kbps,

         

APTX:7K5 Stereo 128Kbps,

         

APTX:15K2 Mono 128Kbps,

         

APTX:12K2 Stereo 192Kbps,

         

APTX:22K5 Mono 192Kbps,

         

APTX:15K2 Stereo 256Kbps,

         

APTX:22K5 Stereo 384Kbps)

set password

(Not Set (pin), 

Edit Lock (pin),

Full lock (pin))

set isdn

G711:3K2 Dual 64Kbps,
G722:7K5 Dual 64Kbps,
APTX:3K7 Stereo 64Kbps,
APTX:7K5 Mono 64Kbps,
APTX:7K5 Stereo 128Kbps,

               APTX:15K2 Mono 128Kbps,
               HIT-APTX:7K5 Stereo 128K,
               HIT-APTX:15K2 Mono 128K)

set mode 

(ISDN Mode,
X21 Mode,
Backup Master,
Backup Slave,
Nailed ISDN)

set mixing (Off, On)
set priority (Bandwidth, Stereo Image)
set autohunt (Off, On)
set alarm (Sync Loss, Backup, Off)
dial (dials the current patch)
hang (hangs the current isdn call)
set rem add (channel) (destination number)
set rem sub (channel) (destination sub addr) 
set loc sub (channel) (local sub address)

The Status command will display the following information
on the codec.

0108-001>status

SYSTEMBASE C510ip(c)
Patch Name= Patch 1
Country= EURO ETSI
Mode= ISDN Mode
ISDN 1= Ready
ISDN 2= Ready
APTX Status= SYNC
Loopback= Off
Aux Data= Off
Alarm= Sync Loss

ISDN OPTIONS
   ISDN Audio= APTX:15K2 Mono 128Kbps
   ISDN Autohunt= Off
   CH1 Rem Add= 1111  Rem Sub=  Loc Sub=
   CH2 Rem Add= 1111  Rem Sub=  Loc Sub=

X21 OPTIONS
   X21 Audio= APTX:22K5 Stereo 384Kbps

AUDIO OPTIONS
   Audio Source= Analog
   ISDN Priority= Bandwidth
   ISDN Mixing= Off

BACKUP OPTIONS
   Backup Level= 50
   Restore Time= 10
   Reserve Dial= Off

Page 22

Summary of Contents for C510ip-s

Page 1: ...Page 1 SystemBas IP Audio Codecs USER MANUAL C510ip s REL300 upwards...

Page 2: ...P Ethernet Mode 14 IP Packet Size 14 SIP Remote Port 15 SIP Local Port 15 SIP Audio Port 15 SIP Public IP 15 X21 Audio 15 Backup Options 15 Backup Monitor 15 Backup Threshold 15 Restore Time 15 Reserv...

Page 3: ...Kbps SIP Compatibility with other Manufacturers SIP Server Registration and telephony support SIP Hybrid Function supporting standard G711 and HD voice calls Unicast Simulcast Multicast IGMPV2 X 21 Co...

Page 4: ...to a host computer network for the purposes of codec management The WEB GUI is based on XML data and lightweight JS This means that it will function on Chrome Mozilla IE8 MAC OS and mobile phones with...

Page 5: ...er to access 1 of 26 pre stored configuration memories MENU Patch Dial 1 PATCH 1 The and buttons can be used to select the required patch 1 of 26 A third depression of the DIAL button instructs the un...

Page 6: ...Page 6 FRONT REAR PANELS...

Page 7: ...Page 7 MENU MAP UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT...

Page 8: ...Page 8 IP MENU MAP UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT...

Page 9: ...for the ISDN B Channels INFO CH1 CALLER ID 01256880123 Clearing Cause The Clearing Cause for each of the available ISDN B Channels is displayed INFO CH1 CLEARING CAUSE IP Link Status MENU IP Link Stat...

Page 10: ...d with ISDN operation of the unit ISDN Audio Options MENU ISDN Audio Options ISDN Audio Format MENU ISDN Audio Format APTX 15K2 Mono 128Kbps The and buttons can be used to select the required ISDN Aud...

Page 11: ...SDN parameters associated with each ISDN B Channel can be changed The C510ip s has 2 ISDN B Channels The following 3 option menus are repeated for all available Channels ISDN Remote Address MENU CH1 R...

Page 12: ...once it has been confirmed On completion press the YES button to save the changes and the NO button to abort the changes If a Mutlicast address is specified and AutoCon initiated then the codec will...

Page 13: ...is disrupted for any reason including power reset IP Local Options MENU IP LOCAL OPTIONS The next level of the menu system allows the user to modify the Local IP parameters IP Local Name MENU IP LOCAL...

Page 14: ...be manually adjusted 1 n Packets as required IP Group ID MENU IP GROUP ID 1234 The IP Group ID is associated with the Systembase AoIP protocol and used to prevent the C510ip s Codec from accepting IP...

Page 15: ...22K5 Mono 192Kbps APTX 12K2 Stereo 192Kbps APTX 15K2 Mono 128Kbps APTX 7K5 Stereo 128Kbps APTX 7K5 Mono 64Kbps APTX 3K7 Stereo 64Kbps NOTE When operating in Mono only the Left Input and Left Output a...

Page 16: ...g the Backup Options menu NOTE When operating in ISDN Backup Master Slave mode it is advised that the DCE should carry X 21 termination resistors Backup Master X21 IP Slave X21 IP The X 21 port is the...

Page 17: ...droom MENU Headroom 12dBu Headroom can be configured to either level System Options The user can modify the global System configurations of the Codec Country Options There are a number of ISDN paramet...

Page 18: ...0BASE TX half duplex Note The C510ip s supports DNS which will automatically configure the DHCP is enabled If you wish to manually configure the DNS server address then that may be achieved via the WE...

Page 19: ...e been configured and registered on the SIP server it is possible to place a call from one to the other using the other codecs user name For example if the two codec names were codecA and codecB then...

Page 20: ...your router On your computer web browser type in the IP address of the codec http 192 168 1 2 A Windows Login screen will be displayed The default Username is admin and the default password is admin...

Page 21: ...tiple codecs in a single browser window with minimal overhead EasyMON is free and maybe downloaded from the systembase website www systembase com Included in the download are instructions that will gu...

Page 22: ...S3 set loopback Off On set x21 APTX 3K7 Stereo 64Kbps APTX 7K5 Mono 64Kbps APTX 7K5 Stereo 128Kbps APTX 15K2 Mono 128Kbps APTX 12K2 Stereo 192Kbps APTX 22K5 Mono 192Kbps APTX 15K2 Stereo 256Kbps APTX...

Page 23: ...This facility allows the user to connect AES3 signal sources that are asynchronous to the codecs network interface The electrical characteristics of these connections is detailed below I P Connectors...

Page 24: ...OM 7 Relay 1 N O 8 GND 9 Opto 1 i p Opto Input Trigger by strapping to ground Manager Output Port Type V 24 RS232 Fixed DTE Speed 9600bps 8 n 1 Signals TXD RXD SIG GND Connector 9 way Dsub Female PIN...

Page 25: ...to 90 RH Operating Altitude 3000 meters WARRANTY INFORMATION Systembase Limited warrants that this product is free from defects in materials or workmanship for 12 months from delivery Upon proof of p...

Page 26: ...able at the time of publication The manufacturer reserves the right to change details without notice Systembase is a trademark of Systembase Limited apt X is a trademark of APT Licensing Ltd All trade...

Reviews: