SystemAir Topvex FC Series Installation Instructions Manual Download Page 5

Declaration of conformity |

1

1

Declaration of conformity

Manufacturer

Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg SWEDEN
Office: +46 222 440 00 Fax: +46 222 440 99
www.systemair.com

hereby confirms that the following products:

Air handling units

Topvex FC02 EL

Topvex FC02

Topvex FC02 HWL

Topvex FC02 HWH

Topvex FC04 EL

Topvex FC04

Topvex FC04 HWL

Topvex FC04 HWH

Topvex FC06 EL

Topvex FC06

Topvex FC06 HWL

Topvex FC06 HWH

(The declaration applies only to product in the condition it was delivered in and installed in the facility in accordance with the included
installation instructions. The insurance does not cover components that are added or actions carried out subsequently on the
product)

Comply with all applicable requirements in the following directives and regulations

Machinery Directive 2006/42/EC

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans
1253/2014 Requirements for ventilation units

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

The following harmonized standards are applied in applicable parts:

EN ISO 12100:2010

Safety of machinery - General principles for design - Risk assessment and risk reduction

EN 13857

Safety of machinery – Safety distances to prevent hazard zones being reached by upper
or lower limbs

EN 60204-1

Safety of machinery – Electrical equipment of machines – Part 1: General requirements

EN 60335-1

Household and similar electrical appliances – Safety Part 1: General requirements

EN 60335-2-40

Safety of household and similar electrical appliances - Part 2-40: Particular requirements
for electrical heat pumps, air-conditioners and dehumidifiers

EN 50106:2007

Safety of household and similar appliances – Particular rules for routine tests referring to
appliances under the scope of EN 60 335-1 and EN 60967

EN 60529

Degrees of protection provided by enclosures (IP Code)

EN 62233

Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for
industrial environments

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standards
for residential, commercial and light-industrial environments

The complete technical documentation is available.

Skinnskatteberg, 04-04-2018

Mats Sándor
Technical Director

151627 | A002

Summary of Contents for Topvex FC Series

Page 1: ...Document in original language 151627 A002 Topvex FC Compact Air Handling Unit Installation instructions GB...

Page 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...re how to install 6 4 3 Condensation drain 7 4 4 Installing the unit 9 4 4 1 Installation procedure 10 4 5 Supply air sensor 10 4 6 Mounting the sliding door kit 11 4 7 Connections 13 4 7 1 Ducting 13...

Page 4: ......

Page 5: ...fety of machinery General principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60204...

Page 6: ...er maintenance shall not be made by children without supervision 3 Product information 3 1 General This installation manual concerns air handling unit type Topvex FC manufactured by Systemair Sverige...

Page 7: ...A D 70 70 E 148 I H G J K 137 98 98 L F A A A A A A 1 2 M Fig 1 Dimensions Topvex FC02 mm drawn as right hand unit male connection Model A B C D E F Topvex FC02 1500 2101 1919 1208 1577 1720 Model G...

Page 8: ...098 2242 Topvex FC06 2214 2546 1182 1208 2288 2432 Model G H I J K L M Weight kg Topvex FC04 446 979 600 200 250x500 200 400 420 Topvex FC06 471 1073 671 250 300x600 300 500 510 3 2 2 Space required I...

Page 9: ...orted in such a way that it is protected against physical damage that can harm panels handles display etc It should be covered so that dust rain and snow cannot enter and damage the unit and its compo...

Page 10: ...ection doors downwards When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec tion doors should be easily accessible Leave free space for...

Page 11: ...id On left hand units the positions of the connection are reversed See table 1 how the height H corresponds to different maximum negative pressures If the unit is mounted in a tight area that makes it...

Page 12: ...8 Installation 2 185 H 32 mm G Fig 4 Drainage connection right hand unit Table 1 H mm Max Negative pressure Pa 65 300 951 600 135 1000 1 Normal conditions 151627 A002...

Page 13: ...gned for ceiling installation Left and right connections are possible Fig 5 Installing position left hand unit Fig 6 Installing position right hand unit Table 2 Symbol description Symbol Description S...

Page 14: ...the installation in accordance with local rules and regulations Install the unit with 0 3 lean towards drainage connections 2 Lift the unit in place 3 Connect the unit electrically to the mains power...

Page 15: ...the unit is put into operation to ensure the required level of safety for the unit 1 Hinges Close the hatch with all 4 or 6 handles depending on model and unscrew the 2 hinges 2 Repeat procedure Repe...

Page 16: ...e pushed toward the centre of the unit On ly one hatch at the time can be opened like this 7 Apply seal Apply the enclosed self adhesive seal strip to the in ner frame of the unit casing 8 Close hatch...

Page 17: ...pply air 2 Fan extract air 3 Filter supply air 4 Filter extract air 5 Heat exchanger 6 Electrical connection box 7 Damper by pass outdoor air 8 Pressure transmitter supply air fan extract air filter 9...

Page 18: ...oms via the duct system and also to reduce noise from the duct system it self installation of silencers before every inlet diffuser is recommended 4 7 4 Electrical connections components Danger Make s...

Page 19: ...rmer 230 24V AC 3 Terminals for internal and external components 4 Terminals for internal wiring 5 Terminals for power supply to the unit 6 Contactor K2 On Off Pump control water HW units only not pre...

Page 20: ...ence neutral 31 AI 1 Temperature sensor supply air 40 Agnd UI reference neutral 412 UAI 1 UDI 1 Pressure transmitter extract air 422 UAI 2 UDI 2 Pressure transmitter supply air 44 UAI 3 UDI 3 Frost pr...

Page 21: ...3 or 60 61 62 63 TCP IP Exoline TCP IP Modbus TCP IP WEB TCP IP BACnet RS 485 connection Fig 11 TCP IP connection Connect the device to panel outlet or switch module depending on type of air handling...

Page 22: ...its NaviPad has an easy to understand menu structure and contains 13 languages B A C F E D 3 m A B C c cD E F 153 221 40 3 59 4 77 5 3 2 4 8 2 Mounting control panel The NaviPad control panel with 3 m...

Page 23: ...concerning additional external equipment such as valve actuators motorized dampers roof units wall grilles etc see technical catalogue and their enclosed instructions For electrical connections of ex...

Page 24: ...Topvex FC Installation instructions 151627 en_GB 2018 10 11 A002 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com...

Reviews: