background image

EU Declaration of conformity |

1

1

EU Declaration of conformity

Manufacturer

Systemair Sverige AB
Industrivägen 3
SE-739 30 Skinnskatteberg SWEDEN
Office: +46 222 440 00 Fax: +46 222 440 99
www.systemair.com

hereby confirms that the following products:

Roof fans TFC 225-560 S/P

(The declaration applies only to product in the condition it was delivered in and installed in the facility in accordance with the included
installation instructions. The insurance does not cover components that are added or actions carried out subsequently on the
product)

Comply with all applicable requirements in the following directives and regulations

Machinery Directive 2006/42/EC

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans
1253/2014 Requirements for ventilation units

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

The following harmonized standards are applied in applicable parts:

EN ISO 12100:2010

Safety of machinery – General principles for design – Risk assessment and risk reduction.

EN 13857

Safety of machinery – Safety distances to prevent hazard zones being reached by upper
or lower limbs.

EN 60 335-1

Household and similar electrical appliances – Safety Part 1: General requirements.

EN 60 335-2-80

Household and similar electrical appliances – Safety – Part 2-80: Particular requirements
for fans.

EN 62233

Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure.

EN 50 106:2007

Safety of household and similar appliances – Particular rules for routine tests referring to
appliances under the scope of EN 60 335-1 and EN 60967.

EN 60529

Degrees of protection provided by enclosures (IP Code).

EN 60 204-1

Safety of machinery – Electrical equipment of machines – Part 1: General requirements

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for
industrial environments.

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standards
for residential, commercial and light-industrial environments.

The complete technical documentation is available.

Skinnskatteberg, 09-05-2016

Mats Sándor
Technical Director

206434 | A006

Summary of Contents for TFC 225 P

Page 1: ...Document in original language 206434 A006 Roof fans TFC 225 560 S P Operation and Maintenance Instructions GB...

Page 2: ...Systemair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously...

Page 3: ...3 Wiring diagram 6 3 2 4 Residual current devices 10 3 3 Transportation and storage 10 4 Installation 10 4 1 Installing the fans 11 4 2 Change from VAV to CAV 13 4 3 K factor 13 4 4 Commissioning 14 4...

Page 4: ......

Page 5: ...essment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60 335 1 Household and similar electrical appliances Safety Pa...

Page 6: ...ies Caution Indicates a risk of damaging the product or prevent optimal operation Important This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 7: ...ms The fans are meant for use in ducted systems and should always be duct connected on the inlet side No moving parts shall be accessible after installation TFC 225 560 S P roof fans are adapted to co...

Page 8: ...B C D E F G H Weight kg TFC 225 413 422 281 330 435 266 49 195 12 4 TFC 280 514 523 333 450 535 368 86 245 17 1 TFC 355 618 627 376 535 637 491 150 300 27 5 TFC 450 728 737 417 655 747 602 176 375 35...

Page 9: ...10V TFC 280 2 6V 0 0 4 0 8 1 2 1 6 0 250 500 750 1000 Q m s Ps Pa 0 1000 2000 3000 4000 5000 m h 16745 16744 5V 7 3V 10V TFC 355 2 5V 0 0 5 1 1 5 2 0 200 400 600 800 Q m s Ps Pa 0 2000 4000 6000 m h 1...

Page 10: ...s possible from TFC 355 see wiring diagram Tacho 0 10V DC Ext RD YE BU WH 1 3 2 4 BU BN BK GN YE 230V 1 N L PE 1 TFC 225 280 S M RSA RSB 0 10V DC Ext RD YE BU WH BN 1 3 2 4 230V 1 BU BN GN YE N L PE G...

Page 11: ...1 PE L3 GY BK BN GN YE 0 10V DC Ext RD YE BU WH BN RSA RSB WH 2 WH 1 BK 3 BK 2 BK 1 GN YE 1 TFC 500 S M 3 1 3 2 4 400V 3 5 6 BK BN GN YE GY C NC L3 L2 L1 PE L2 L1 PE L3 GY BK BN GN YE 0 10V DC Ext 10V...

Page 12: ...N BK GN YE N L PE Tacho A GND US GND 1 2 TFC 225 280 P M 10V DC 10 24 V DC 2 1 Ri 4 k 1 3 2 4 230V 1 RD YE BU WH BN BU BN GN YE WH 2 WH 1 BU BK GN YE N L PE BU BN GN YE RSA RSB A GND US GND 1 2 1 2 TF...

Page 13: ...4 400V 3 5 6 BK BN GN YE GY C NC L3 L2 L1 PE L2 L1 PE L3 GY BK BN GN YE 10V Ain1U GND RSA RSB A GND US GND 1 2 TFC 560 P M 3 10V DC 10 24 V DC 2 1 Ri 4 k 1 Safety switch 2 Fan control 3 Alarm RD Red...

Page 14: ...ft the fans by the connecting cable connection box motor bracket impeller or inlet cone 4 Installation Danger Make sure that the mains supply to the unit is disconnected before performing any maintena...

Page 15: ...cal compartment Figure 2 Connect the mains supply to the lockable safety switch 1 Image show S controller 2 The hinges on the hatch to the electrical compartment prevents the hatch from falling down F...

Page 16: ...on 4 5 Figure 5 Mains supply 4 can be run through the cable glands beside the electrical compartment or inside a roof curb if used Note Don t cover this gap 5 It is for drainage if water enters the fa...

Page 17: ...nection to the con troller the tubing from the bottom of the fan 1 to plus inlet and the tubing from the cone 2 to minus The tubing from the cone is labelled with blue tape In BASE SETUP 5 01 in table...

Page 18: ...Rated current must not be exceeded with more than 5 at rated voltage The direction of rotation should correspond to direction of rotation arrow 3 phase Smoothness of motor operation no abnormal noise...

Page 19: ...t for Escape Esc Info Selection of the menu group e g BASE SETUP to the right through the key to the left through the key You can go to the menu items in the menu groups e g mode by using the P key Us...

Page 20: ...depending on adjusted setpoint and measured actual value Table 1 Parameter table Parameter Display Factory setting Function Mode 4 00 4 01 5 00 5 01 Mode INFO Information p 0 Pa 0 Pa Different actual...

Page 21: ...01 0 100 sensor measuring range 5 01 0 Max Range qV depending on K factor and sensor measuring range 2 Small value quick regulation great value slow regulation high stability BASE SETUP Base setup Mod...

Page 22: ...cessary at least once a year to avoid imbalance and unnecessary damage to the bearings The fan bearings are maintenance free and should only be replaced if damaged Do not use a high pressure cleaner s...

Page 23: ...ce release the lock using the handle to bring the motor down Fasten the motor bracket with the screws Note TFC 225 and TFC 280 has no handle hold the motor bracket to lift the motor 7 Troubleshooting...

Page 24: ...of fans Operation and Maintenance Instructions 206434 en_GB 21 11 2017 A006 Systemair Sverige AB Industriv gen 3 SE 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair co...

Reviews: