![SystemAir SAVEWALL HRV NEXT Installation Manual Download Page 16](http://html1.mh-extra.com/html/systemair/savewall-hrv-next/savewall-hrv-next_installation-manual_1423140016.webp)
16
a) Mark
-
SYSTEMAIR
b) Model
-
SAVEWALL HRV NEXT
c) SEC class
-
A
c1) SEC warm climates
kWh/m2.a
-18,1
c2) SEC average climates
kWh/m2.a
-41,7
c3) SEC cold climates
kWh/m2.a
-83
Energy label
-
Yes
d) Unit typology
-
Residential - bidirectional
e) Type of drive
-
Multi-speed drive
f) Type of Heat Recovery System
-
Heat recovery
g)
Thermal efficiency of heat recovery
%
74
h)
Maximum flow rate
m3/h
60
i)
Electric power input at maximum flow rate
W
6
j) Sound power level (L
WA
)
dBA
40
k)
Reference flow rate
m3/h
41
l)
Reference pressure difference
Pa
10
m)
Specific power input (SPI)
W/m3/h
0,08
n1) Control factor
-
0,65
n2) Control typology
-
Local demand control
o1) Maximum internal leakage rate
%
N/A
o2) Maximum external leakage rate
%
1
p1)
Internal mixing rate
%
N/A
p2) External mixing rate
%
N/A
q)
Visual filter warning
-
N/A
r)
Instructions to install regulated grilles
-
N/A
s)
Internet address for pre/disassembly instructions
-
www.systemair.gr
t)
Airflow sensitivity to pressure variations
%
N/A
u)
Indoor/outdoor air tightness
m3/h
50
v1)
AEC - Annual electricity consumption - warm climates
kWh
0,6
v2)
AEC - Annual electricity consumption - average climates
kWh
0,6
v3)
AEC - Annual electricity consumption - cold climates
kWh
0,6
w1)
AHS - Annual heating saved - warm climates
kWh
19,5
w2)
AHS - Annual heating saved - average climates
kWh
43,2
w3)
Annual heating saved - cold climates
kWh
84,4
ErP Directive - Regulations 1253/2014 - 1254/2014
Summary of Contents for SAVEWALL HRV NEXT
Page 7: ...7 12 11 14 13 15 L N R R B B L N L N 16B 4 x 5mm L N 16A...
Page 8: ...8 17 19 20 21 CLICK ON OFF 115 mm colorare filtro 22 18 ON OFF...
Page 17: ...17 NOTES...
Page 18: ...18 NOTES...
Page 19: ...19 NOTES...