UK Declaration of Conformity

We, the manufacturer

Manufacturer

Systemair Sverige AB

Address

Industrivägen 3

SE-73930 Skinskatteberg

Sweden

declare under our sole responsibility that the products

Type/Model

RVF

Identification

Serial numbers dating from 2022 and onwards

fulfils the relevant provisions of following directives and
standards

Supply of Machinery (Safety) Regulations 2008

EN ISO 12100:2010

Safety of machinery – General principles for design - Risk
assessment and risk reduction

EN ISO 13857:2019

Safety of machinery – Safety distances to prevent hazard
zones being reached by upper or lower limbs

EN 60204-1:2018

Safety of machinery – Electrical equipment of machines –
Part 1: General requirements

EN 60335-1:2012

Household and similar electrical appliances – Safety Part 1:
General requirements.

EN 60 335-2-80:2003

Household and similar electrical appliances – Safety – Part
2-80: Particular requirements for fans.

EN 50106:2008

Safety of household and similar appliances – Particular rules
for routine tests referring to appliances under the scope of
EN 60 335-1.

EN 60529:2014

Degrees of protection provided by enclosures (IP Code).

Electromagnetic Compatibility Regulations 2016

EN 62233:2008

Measurement methods for electromagnetic fields of
household appliances and similar apparatus with regard to
human exposure

EN 61000-6-2:2005

Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments.

The Restriction of the Use of Certain Hazardous
Substances in Electrical and Electronic Equipment
Regulations 2012

EN IEC 63000:2018

Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of
hazardous substances

The Ecodesign for Energy-Related Products and Energy
Information (Amendment) (EU Exit) Regulations 2019

327/2011 Requirements for fans above 125W

1253/2014 Requirements for ventilation units above 30W

1254/2014 Requirements for energy labelling of residential
ventilation units

EN ISO 5801:2017

Fans – Performance testing using standardized airways.

EN 13142:2021

Ventilation for buildings – Components/Products for
residential ventilation – required and optional performance
characteristics.

Persons authorized to compile the technical file:

Stefan Lindberg

Technical Manager

This declaration relates exclusively to the machinery in the
state in which it was placed on the market and excludes
components which are added or operations carried out
subsequently by the final user.

Skinnskatteberg, Sweden 2022-06-03

Sofia Rask

Managing Director

24

Summary of Contents for RVF

Page 1: ...Installation Operation and Maintenance instruction EN RVF wall fan AC EC...

Page 2: ...the commissioning 6 6 2 To do the commissioning 6 7 Operation 6 7 1 To start a product with an EC motor 6 7 2 To start a product with an AC motor 6 7 3 To stop the product 6 7 3 1 To stop the product...

Page 3: ...nts with ambient tempera tures of between 25 C and 70 C The product is not applicable for transportation of air that contains explosive flammable or aggressive media The product is not applicable for...

Page 4: ...uses in these conditions The product is incorrectly installed operated or maintained The product is repaired with parts that are not original spare parts from Systemair The product is used together wi...

Page 5: ...rmation about your product The product is not to be used by persons including chil dren with reduced physical sensory or mental capabil ities or lack of experience and knowledge unless they have been...

Page 6: ...product to install the product in the correct position Make sure that all cable glands are tight against the ca bles to prevent leaks 4 2 To install the product 1 Remove the screws on the side of the...

Page 7: ...se power supply for the speed controller Refer to 12 3 Wiring diagrams page 12 and the instruction manual for the external speed controller 5 4 Motor protection for EC motors EC motors have an integra...

Page 8: ...the ON position 6 Start the product 7 Set the minimum operation speed 8 Increase the operation speed gradually to the maximum operation speed a Examine the vibrations in the casing and the bearing are...

Page 9: ...protective equipment and the me chanical protective equipment operates correctly X X Make sure that you can read the name plates of the product X X Examine all cable connections for damage Make sure...

Page 10: ...il the product operates smoothly Refer to 6 Commissioning page 6 The air output is not sufficient The fan impeller does not turn in the correct direction Make sure that the electrical connection is co...

Page 11: ...al blockage Remove the blockage Phase loss occurs If the motor is a 3 phase motor make sure that no phase is missing The motor does not rotate A component in the power supply is defective Do a check o...

Page 12: ...lectrical connection and installation 2 Recycle the product parts and the packaging at an appli cable disposal location 3 Obey the local and national requirements for disposal 11 Warranty For warranty...

Page 13: ...lass IP class Voltage current frequency enclosure class weight Refer to the name plate Refer to 1 5 Name plate page 1 for more information Motor data Refer to the motor name plate or the technical doc...

Page 14: ...Wiring diagrams for AC fans RVF fans 1 phase 230 V RVF 100 BU BK GY N L 12 3 2 Wiring diagrams for EC fans Note An internal potentiometer is installed on the terminal block from the factory Remove the...

Page 15: ...N N L L N N N M M REE 4 Surface mounting Note Starting currents must be considered when you select the speed controller type Products that are used with this speed controller must have a built in ove...

Page 16: ...ormer knob is in one of the positions 1 5 B Mains supply C Earth D Fan E Thermostat F Motor protection If the motor protection is not in use Tk must be looped together FRQ5S E 6A Frequency converter w...

Page 17: ...fixed steps The steps are adjusted by using the control knob on the front of the unit RTRD2 7 N L1 L2 L3 L3 L2 L1 N PE U V W PE V W U TB TB TK TK RT L L N 230 V AC RT FS FS Y M 3 0 1 A A A B C D F E A...

Page 18: ...0 1 5 4 2 3 C B D E G F RTRDU 0 1 A A A A If the function is not necessary the terminals must be bridged B Contact rating 230 V AC maximum 1 A C Time switch D OFF ON E OFF ON only by reset F Mains su...

Page 19: ...asic EC Basic 230V AC 1 IN Vac 2 IN Vac 4 Out 5 GND 10V 0 10V GND MTV 1 10 MTV 1 010 1 IN Vac 2 IN Vac 4 Out 5 Out 10V 0 10V GND 230V AC S 5EC FRQ MTP 10 GND 10V A 10V 0 10V GND EC Vent EC Vent IN RPM...

Page 20: ...y NO Relay NC 10V 0 10V GND Din1 12 3 6 Wiring diagrams for demand control for EC motors EC Basic EC Basic T for temperature control EC Basic 230V AC 1 IN Vac 2 IN Vac 4 Out 5 GND 10V 0 10V GND EC Bas...

Page 21: ...stem has 2 units The control board CB and the room unit RU Connect the fan to the control board and remove the internal potentiometer EC Vent IN RPM PWM IN 10V OUT PWN GND TACH optional 10V 0 10V PWM...

Page 22: ...GND A D PT1000 24V N out N in L out L in IN3 IN2 IN2 A Mains supply 230 V 1 AC 10 A B Analogue sensor for example pressure sensor C Analogue sensor for example pressure sensor type PT1000 D Digital s...

Page 23: ...System neutral Mains supply 24 V AC Signal neutral Signal neutral Output minimum 0 10V Output maximum 0 10V PCA 1000D2 Pressure controller For constant air volume control CAV or variable air volume co...

Page 24: ...w 3 1 4 5 2 1 Fan 2 FK fast clamp 3 RSK Back draft damper 4 LDC Silencer 5 Balance E extract air diffuser Note For more information about accessories refer to www systemair com or speak to Systemair t...

Page 25: ...Code Directive electromagnetic compatibility EMC 2014 30 EU EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EN...

Page 26: ...ons 2016 EN 62233 2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EN 61000 6 2 2005 Electromagnetic compatibility EMC Pa...

Page 27: ...25...

Page 28: ...r AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair Sverige AB In...

Reviews: