2

Product information

3

Product information

3.1

Key for item name

prio silent XP = Revolution silenced V2

3.2

Intended use

• The fans are intended for installation in ventilation systems. They can be installed both in duct systems and also with

free suction via a suction-side contact protection grille. Free discharge via a contact protection grille is also possible.

• The fan is suitable for conveying clean air.

Incorrect use

Incorrect use refers mainly to using the fan in another way to that described. The following examples are incorrect
and hazardous:

• Conveying of explosive and combustible media

• Conveying of aggressive media

• Operation in an explosive atmosphere

• Operation without duct system or protection grille

• Operation with the air connections closed

• Installation outside without weather protection

3.3

General

This manual concerns prio 150–250 and prio silent XP 150–315 (manufactured by Systemair GmbH).

This manual consists of basic information and recommendations concerning the design, installation, start-up and opera-
tion, to ensure a proper fail-free operation of the unit. The key to proper and safe operating of the unit is to read this
manual thoroughly, use the unit according to given guidelines and follow all safety requirements.

Valid for fans without connection cables

The

EC-fans

are delivered with potentiometer, 0–10 V. The integrated potentiometer is factory preset to 10 V. This val-

ue can be changed manually to obtain a different motor rpm/fan performance. An external potentiometer or other con-
troller can be connected if necessary, see 3.4.2

Wiring diagram

, page 4.

Danger

• The fans are not to be used in hazardous environments or connected to flue ducts.

• The appliance must be connected to a mains circuit breaker in the fixed installation.

• Switch power off (all-pole circuit breaker) before servicing or maintenance, and make sure the impeller

has come to standstill.

• Make sure protection grid has been installed (EN ISO 13857), no moving parts shall be accessible after

installation.

• Do not remove, short-circuit or disconnect safety accessories (i.e. motor protection, safety grille).

Warning

• The fans can have sharp edges and corners which may cause injuries. Be careful when opening the fans,

the motor assembled on the motor bracket is relatively heavy.

Caution

• Take precautions to prevent the back flow of exhaust gases from flues from other appliances installed in

the same room, which are fired by gas or other fuels.

| 002

Summary of Contents for prio 150E2

Page 1: ...Document in original language 002 Circular duct fan prio 150 250 prio silent XP 150 315 Installation and Operating Instructions GB...

Page 2: ...emair AB All rights reserved E OE Systemair AB reserves the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agr...

Page 3: ...item name 2 3 2 Intended use 2 3 3 General 2 3 4 Technical data 3 3 4 1 Dimension 3 3 4 2 Wiring diagram 4 3 5 Transportation and storage 5 4 Installation 6 4 1 Commissioning 8 5 Maintenance 8 5 1 Imp...

Page 4: ......

Page 5: ...are CE marked by other manufacturer 2 Warnings The following admonitions will be presented in the different sections of the document Danger Indicates a potentially or imminently hazardous situation wh...

Page 6: ...ng of the unit is to read this manual thoroughly use the unit according to given guidelines and follow all safety requirements Valid for fans without connection cables The EC fans are delivered with p...

Page 7: ...211 187 40 prio 160E2 prio 160EC 220 159 211 187 25 prio 200E2 prio 200EC 245 199 249 227 25 prio 250E2 prio 250EC 300 249 303 284 30 prio 250E2 L prio 250EC L 300 249 303 284 30 Table 2 Dimensions pr...

Page 8: ...XP 150EC prio silent XP 160EC prio silent XP 200EC prio Silent XP 250EC prio Silent XP 250EC L Table 3 Terminals Description Function assignment 10 V GND 0 10 V PWM Tacho L PE N L Power supply 230 V...

Page 9: ...GND optional PWM 3 5 Transportation and storage All fans are packaged at the factory to withstand normal transport handling When handling the goods use suitable lift ing equipment in order to avoid da...

Page 10: ...an is firmly fixed and stable The fans must be installed to ensure that service and maintenance can be performed easily and safely Important Damage to the bearings or other parts of the fan can occur...

Page 11: ...150 315 A Flap 4 x Example Rope installation B Optional key hole Overview Details A B C D Y A Sleeve with female thread M8 C Nut M8 B Screw M8 e g DIN 933 D Washer Y Installation example Rail or screw...

Page 12: ...ans by the connecting cable connection box motor bracket impeller or inlet cone 5 2 Cleaning the fan Warning Make sure that the mains power supply to the unit is disconnected before performing any mai...

Page 13: ...regulations The device and the transport packaging are predominantly made from recyclable raw materials Disassemble the fan into its components Separate the parts according to reusable material materi...

Page 14: ...lar duct fan Installation and Operating Instructions en_GB 2020 07 22 002 Systemair GmbH Seeh fer Str 45 97944 Boxberg Germany Tel 49 0 7930 9272 0 Fax 49 0 7930 9273 92 info systemair de www systemai...

Reviews: