![SystemAir fantech SHR1200 Installation Manual Download Page 4](http://html.mh-extra.com/html/systemair/fantech-shr1200/fantech-shr1200_installation-manual_1423356004.webp)
4
Installation
Location
The HRV must be located in a heated space where it will be possible to conveniently service the unit. Typically the HRV would be located in the
mechanical room, above a drop ceiling or an area close to the outside wall where the weatherhoods will be mounted. Attic installations are not normally
recommended due to extreme temperatures, and difficulty in performing required service & maintenance. If an attic is selected, special care should be
taken in ensuring the unit will perform as intended. Unit may need to be protected with insulated shelter, built on site.
Connecting appliances to the HRV
It is not recommended, including:
• clothes dryer
• kitchen exhaust hoods
• combustion venting
• central vacuum system
These appliances may cause lint, dust or grease to collect in the HRV , damaging the unit.
Connecting any of these type of appliances to the HRV will invalidate your warranty
A
B
C
D
E
F
G
Model
A
B
C
D
E
F
G
Kg
lbs
Kg
lbs
in.
mm.
Kg
lbs
Kg
lbs
Kg
lbs
in.
mm.
SHR 450
16.6
36.6
15.6
34.4
12.6
320
58
127.9
13.6
30
12.7
28
17.63
448
SHR 700
23.8
52.5
22.5
49.6
15.4
390
85
187
20
44
18.8
41.3
17.6
448
SHR 800
20
44
17
37.5
15.9
404
71.5
158
19
41.9
16.5
36.4
11
282
SHR 1200
30.4
67
27
60
21.4
544
109
241
27.7
61
24.3
53.5
18
455
SHR 1400
29.2
64.4
24.5
54
19
483
116
255
30
66.2
34.7
76.5
10
254
Summary of Contents for fantech SHR1200
Page 15: ...15 Wiring Diagram SHR 450 ...
Page 16: ...16 Wiring Diagram SHR 700 SHR 800 ...
Page 17: ...17 Wiring Diagram SHR 1200 SHR 1400 ...
Page 18: ...18 Wiring Diagram SHR 1200 SHR 1400 Cont d ...
Page 37: ...37 Connexions électriques SHR450 ...
Page 38: ...38 Connexions électriques SHR700 SHR800 ...
Page 39: ...39 Connexions électriques SHR1200 SHR1400 ...
Page 40: ...40 Connexions électriques SHR1200 SHR1400 Suite ...
Page 50: ...50 Notes ...
Page 51: ...51 Notes ...