Summary of Contents for fantech FIT 120H

Page 1: ...and or ASHRAE s Good Engineering Practices Fantech reserves the right to modify at any time and without notice any or all of its products features designs components and specifications to maintain the...

Page 2: ...combustion equipment i e Gas Furnaces Oil Furnaces Wood Stoves etc Products are designed and manufactured to provide reliable performance but they are not guaranteed to be 100 free of defects Even rel...

Page 3: ...ducting to the weatherhood 8 INTERIOR DUCTING INSTALLATION General Tips 9 Installing duct to HRV 9 Supply Exhaust air grilles location 9 HRV INSTALLATION 11 Mounting 12 Drain line installation 14 AIRF...

Page 4: ...53 25 60 28 501 1000 47 93 45 21 53 24 60 28 68 31 75 35 1001 1500 94 139 60 28 68 31 75 35 83 38 90 42 1501 2000 140 186 75 35 83 38 90 42 98 45 105 49 2001 2500 187 232 90 42 98 45 105 49 113 52 120...

Page 5: ...The HRV s airflow must be balanced after installation using the procedure found in the section AIRFLOW BALANCING Suggested installation for Hydronic baseboard Infloor heating Electric baseboard Mini s...

Page 6: ...Fresh air to living areas Fantech heat recovery ventilators HRV that use a supply fan shutdown for frost preven tion do not include an outdoor air motorized damper If you are using a simplified insta...

Page 7: ...installing any installation type requiring the use of the furnace interlock Stale air to outside Fresh air from outside Fresh air to living areas Fantech heat recovery ventilators HRV that use a suppl...

Page 8: ...to living areas Stale air to outside Fresh air from outside Fantech heat recovery ventilators HRV that use a supply fan shutdown for frost preven tion do not include an outdoor air motorized damper If...

Page 9: ...er which acts as a vapor barrier must be completely sealed to the outer wall and the HRV using tape and or caulking A good bead of high quality caulking preferably acoustical sealant will seal the inn...

Page 10: ...ible duct to prevent leakage between the ducting and the duct connection In the case of solid ducting slide duct over duct connection screw in place and seal Supply air grilles location In homes witho...

Page 11: ...at the condensate drains and is protected from freezing The attic is easily accessible for equipment maintenance and inspection Connecting appliances to the HRV is not recommended These include Clothe...

Page 12: ...he bracket is straight Mounting MOUNTING BRACKET 4 Install the unit by sliding the unit in the guide of the ceiling bracket We recommend placing the duct on the unit at this stage of the unit s instal...

Page 13: ...hten 3 Install a spring on each chain Hook the spring in the links so a loop is created in the chain The spring will then support the unit s weight and absorb vibrations 4 Hang the unit by slipping a...

Page 14: ...en away by a condensate pump The HRV and all condensate lines must be installed in a space where the temperature is maintained above the freezing point A P trap should be made in the drain line This w...

Page 15: ...perating at normal speed during the balancing sequence When reading with a mechanical type manometer Magnehelic make sure the manometer is placed on a level surface For optimal performance HRV unit sh...

Page 16: ...airflow velocity should be measured on a section of steel ducting Reading should also be taken at a minimum distance of 457 mm 18 from the unit or elbow Measurement should also be made prior to any t...

Page 17: ...eferred indoor relative humidity range and ventilation mode for day and night conditions No battery to replace all programmed settings are retained during power outage Maintenance reminder indicator E...

Page 18: ...18 Wiring diagram HIGH SPEEDS LOW V 5 5 JP5 JP3 V 5 7 120V 90V LOW JP3 JP5 HIGH 120V 90V 75V 55V SPEEDS Observe polarity on all accessory controls where applicable...

Page 19: ...CTION TO A COOLING SYSTEM On some newer furnaces and older thermostats energizing the R and G terminal at the furnace has the effect of energizing the Y at the thermostat and thereby turning on the co...

Page 20: ...power supply at site Have electrician check supply voltage Ductwork is restricting airflow Check duct installation Improper speed control setting Increase the speed of the HRV i e change unit control...

Page 21: ...al damages incurred in the use of the ventilation system Fantech is not responsible for providing an authorized service centre near the purchaser or in the general area Fantech reserves the right to s...

Page 22: ...22 Notes...

Page 23: ...le droit de modifier partiellement ou enti rement en tout moment et sans pr avis les caract ristiques la conception les composants et les sp cifications de ses produits afin de conserver sa position...

Page 24: ...auffage vacuation fournaise gaz fournaise mazout po le bois etc Les produits sont con us et fabriqu s pour fournir une performance fiable mais ils ne sont pas garantis 100 sans d faut M me les produit...

Page 25: ...ts avec hottes 31 INSTALLATION DES CONDUITS INT RIEURS Conseils pratiques 32 Installation des conduits sur le VRC 32 Emplacement des grilles d approvisionnement et d vacuation 32 INSTALLATION DU VRC 3...

Page 26: ...n L s Pi3 min L s 500 47 30 128 38 18 45 21 53 25 60 28 501 1000 47 93 45 21 53 24 60 28 68 31 75 35 1001 1500 94 139 60 28 68 31 75 35 83 38 90 42 1501 2000 140 186 75 35 83 38 90 42 98 45 105 49 200...

Page 27: ...ge du pr sent manuel d installation Installation sugg r pour Plinthe eau chaude Chauffage de planch Plinthe lectriques Thermopompe mural bibloc Avantages Fourni la meilleure r partition de l air frais...

Page 28: ...vici vacu l ext rieur Air frais provenant de l ext rieur Les ventilateurs r cup rateurs de chaleur VRC de Fantech qui utilisent un arr t du ventilateur d alimentation pour la pr vention de gel ne comp...

Page 29: ...sez une installation simplifi e c est dire relier de conduit d alimentation d air du VRC l aire du conduit de retour d une fournaise le VRC doit fonc tionner en continu Lorsque le VRC est teint pas d...

Page 30: ...d installation le moins dispendieux mettre en place RACCORDEMENT DIRECT du FLUX D AIR D APPROVISIONNEMENT du VRC la BOUCHE DE REPRISE D AIR DE LA FOURNAISE Air vici vacu l ext rieur Air frais provena...

Page 31: ...tre compl tement scell sur le mur ext rieur et le VRC l aide de ruban ou de produit de calfeutrage D posez un cordon de produit de calfeutrage de premi re qualit du mastic d isolation acoustique de pr...

Page 32: ...es crochets Ensuite installez un attache c ble par dessus le conduit flexible afin de pr venir des fuites entre le conduit et le collet Dans le cas d un conduit galvanis faites le glisser sur le colle...

Page 33: ...condensat et est prot g contre le gel Le grenier est facilement accessible pour l entretien du mat riel et de l inspection Il n est pas recommander de raccorder des appareils lectrom nagers au VRC no...

Page 34: ...n caoutchouc Assurez le support est droit 5 Installez l appareil en faisant glisser l unit dans le guide Nous vous recommandons de placer le conduit de l unit ce stade de l installation de l unit 3 En...

Page 35: ...la cha ne Le ressort supportera le poids du VRC et absorbera les vibrations 4 Suspendez le VRC en faisant glisser un maillon de la cha ne dans les crochets de suspension et assurez vous que l appareil...

Page 36: ...e condensat Le VRC et toutes les canalisations de condensats doivent tre install s dans un endroit o la temp rature ambiante est maintenue au dessus du point de cong lation Faisez un siphon en P dans...

Page 37: ...anom tre analogique Magnehelic assurez vous que le manom tre est plac sur une surface plane Afin d assurer une performance optimal le VRC devrait tre r quilibr apr s toute r novation majeure ou apr s...

Page 38: ...ez le d bit d air dans un conduit d acier au moins 457mm 18 po de l appareil ou d un coude et avant toute connexion avec un autre conduit Les mesures devraient tre prises avant toute transition dans l...

Page 39: ...d humidit d sir est atteint votre syst me de ventilation retourne son mode de fonctionnement pr c dent EDF1 Appuyez le bouton pour une vitesse r duite continuelle Appuyez le bouton une seconde fois l...

Page 40: ...40 Sch mas lectroniques HIGH SPEEDS LOW V 5 5 JP5 JP3 V 5 7 120V 90V LOW JP3 JP5 HIGH 120V 90V 75V 55V SPEEDS Respectez la polarit sur tous les accessoires de contr les Le cas ch ant...

Page 41: ...ion de la borne Y du thermostat et cons quemment la mise sous tension du syst me de refroidissement Si votre syst me est muni d un tel type de thermostat vous devez respecter le c blage de verrouillag...

Page 42: ...cacit du VRC V rifiez le r seau de conduits Mauvais r glage de la commande de vitesse Augmentez la vitesse du VRC i e changez la vitesse de l appareil de vitesse R DUITE vitesse NORMALE avec le contr...

Page 43: ...nu de respecter tous les codes en vigueur dans sa r gion Les pi ces y compris les pi ces de rechange pos es ult rieurement sont garanties pendant 5 ans partir de la date d achat de l appareil Les mote...

Page 44: ...5064 1 R2E 190 Radical Rep Kit 414382 2 Electrostatic Filters Kit 422580 3 Heat Recovery Cell 12 x 12 x 7 7 424025 4 Capacitors 8uF 410012 5 Kit PCB Replacement Board AC 422677 6 Auto Transformer 4119...

Page 45: ...45 Notes...

Page 46: ...46 Notes...

Page 47: ...47 Notes...

Page 48: ...make technical changes For updated documentation please refer to www fantech net Fantech Fantech se r serve le droit de faire des changements tech niques Pour de la documentation jour s il vous pla t...

Reviews: