SystemAir DVCompact DXR-10 Installation And Service Download Page 4

2 Warnings

The heat pump unit can cause personal injury if installed or used incorrectly. Read the documentation for
the product carefully before it is installed or commissioned.

Danger

• Make sure that the Mains supply to the unit is disconnected before performing any maintenance or

electrical work!

• All electrical connections must be carried out by an authorized installer and in accordance with

local rules and regulations.

• When carrying out work/service on the cooling circuit(s), the power must be disconnected, and the

work only performed by authorised personnel.

Warning

• Beware of sharp edges during mounting and maintenance. Use protective clothing.

• Skin contact with the refrigerant must be avoided. Use protective equipment such as protective

goggles, gloves and suitable clothing. Good ventilation must be arranged.

• If refrigerant makes contact with skin, carefully wash the exposed part of the body.

• In case of frostbite, treat any damaged skin area and seek medical treatment.

• If refrigerant makes contact with the eyes, immediately use eye wash or lukewarm water and visit a

doctor.

• As the refrigerant is heavier than air, the refrigerant may displace the air and cause asphyxiation in

unfavorable conditions.

Caution

• For safety reasons, only personnel with relevant technical competence may perform installation work.

The installation instructions supplied must be followed.

• The refrigerant for this cooling unit is R410A and cannot be replaced with any other type of refrigerant

without written approval from the supplier.

• Service switches are locked to prevent unauthorized start-up during maintenance work. Where

condensation water needs to be drained away, correct connection to the drain must ensure this. The
installer must equip the unit with operating and maintenance instructions.

• These safety regulations only apply to products supplied by Systemair UAB. It is the installer’s

responsibility to carry out a comprehensive safety assessment of the unit, as well as preparing
safety regulations so that user is able to secure the unit such that it does not cause harm to people,
animals, material or environment. If there is any doubt about how to interpret the regulations covering
safety, installation, operation and maintenance, it is of the utmost importance that advice is sought
from Systemair UAB or its distributors.

Care for the Environment!

• The refrigerant under no circumstances must be released into the environment.

DVCompact

Installation and Service

211117

2

Systemair Sverige AB

Summary of Contents for DVCompact DXR-10

Page 1: ...atalogues brochures and other printed material UAB Systemair reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can b...

Page 2: ...Unloading on the site 7 6 1 1 Unloading by fork lift truck 7 6 1 2 Unloading with crane 8 6 1 3 Lifting the unit mounted on a base frame 8 7 Installation 9 7 1 Unpacking 9 7 2 Where to Install the Un...

Page 3: ...principles for design Risk assessment and risk reduction EN 13857 Safety of machinery Safety distances to prevent hazard zones being reached by upper or lower limbs EN 60 335 1 Household and similar...

Page 4: ...splace the air and cause asphyxiation in unfavorable conditions Caution For safety reasons only personnel with relevant technical competence may perform installation work The installation instructions...

Page 5: ...d or recovered during maintenance servicing and final disposal will need to be recorded along with leak checks actions taken the name of the service Company the engineer technician who performed the s...

Page 6: ...and product number from the type label figure 1 Fig 1 Type label Position Description 1 Product order number 2 Product code product specification 3 Product item number production number consecutive n...

Page 7: ...3510 1720 1720 1497 DVCompact DXR 50 970 2320 4310 2020 2020 2516 DVCompact DXR 60 1120 2320 4610 2170 2170 3309 DVCompact DXR 80 1270 24601 5050 2470 2470 3664 1 This section is split into 3 parts di...

Page 8: ...PM Motor A DVCompact DXR 10 2 2 2 4 2 2 1 DVCompact DXR 15 3 0 3 4 2 6 2 9 DVCompact DXR 20 4 4 4 7 3 6 3 8 DVCompact DXR 25 4 4 6 0 4 7 6 4 4 6 6 3 DVCompact DXR 30 6 0 8 0 6 4 8 2 6 2 8 4 DVCompact...

Page 9: ...emoved and unit covered with tarpaulin or similar materials In order to minimize condensation sufficient air circulation must be ensured between the covering and the unit During transportation the uni...

Page 10: ...on 6 1 3 Lifting the unit mounted on a base frame When lifting the unit mounted on the base frame with holes use metal tubes inserted through the holes in the frame and suspend the unit by soft cables...

Page 11: ...ng should if possible be put in the northern or eastern side of the building and away from other exhaust outlets like kitchen fan outcasts or laundry room outlets The extract air should ideally be led...

Page 12: ...m size 50 don t have the disc lock system Their sections are fitted together by the use of internal triangular brackets that are fitted from factory figure figure 5 Danger Make sure that the Mains sup...

Page 13: ...t figure 4 See wiring diagram for more information Other temperature sensors are built in to the unit from factory Fig 4 Installed supply air sensor 7 4 2 Installation of VAV models If the unit is del...

Page 14: ...ped with traps with same diameter as the drain pipe Fig 6 Drain trap Positive pressure Positive pressure Pa H1 Min mm H2 mm 500 90 65 750 120 90 1000 150 120 Fig 7 Drain trap Negative pressure Negativ...

Page 15: ...wn cable 7 Connection to black cable 7 5 Electrical connections Danger All electrical connections must be carried out in accordance with local rules and regulations Make sure that the power supply to...

Page 16: ...s A and heat pump section pos B The unit must not be put into operation before all the electrical safety precautions have been read and understood See the enclosed wiring diagram for internal and exte...

Page 17: ...51 52 53 LON 57 58 59 RS 485 contact and Exo line via TCP IP WEB are included as standard figure 9 Note RS 485 port and TCP IP port can not be used simultaneously I e possible communications are Modb...

Page 18: ...verige AB reserves the right to make changes and improvements to the contents of this manual without prior notice Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 601...

Reviews: