D690-06-00 4 I56-3071-000
The directional sounder will not work without power.
The directional sounder
gets its power from the fire/security panel monitoring the alarm system. If power
is cut off for any reason, the directional sounder will not provide the desired audio
warning.
The directional sounder may not be heard.
The directional sounder may not be
heard if it is placed on a different floor from the person in hazard or if placed too far
away to be heard over the ambient noise such as traffic, air conditioners, machinery
or music appliances that may prevent alert persons from hearing the sounder. The
Sounder may not be heard by persons who are hearing impaired.
WARNING
The Limitations of Directional Sounders
System Sensor warrants its enclosed product to be free from defects in
materials and workmanship under normal use and service for a period of
three years from date of manufacture. System Sensor makes no other
express warranty for the enclosed product. No agent, representative,
dealer, or employee of the Company has the authority to increase or alter
the obligations or limitations of this Warranty. The Company’s obligation
of this Warranty shall be limited to the replacement of any part of the
product which is found to be defective in materials or workmanship under
normal use and service during the three year period commencing with
the date of manufacture. After phoning System Sensor’s toll free number
800-SENSOR2 (736-7672) for a Return Authorization number, send
defective units postage prepaid to: System Sensor, Returns Department,
FCC Statement
NOTE: Directional Sounder has been tested and found to comply with the limits for a
Class A digital device pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the in-
struction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This Class B Digital Apparatus complies with Canadian ICES-003.
Three-Year Limited Warranty
RA #__________, 6581 Kitimat Road, #6, Mississauga, Ont. L5N-3T5.
Please include a note describing the malfunction and suspected cause
of failure. The Company shall not be obligated to replace units which
are found to be defective because of damage, unreasonable use,
modifications, or alterations occurring after the date of manufacture. In
no case shall the Company be liable for any consequential or incidental
damages for breach of this or any other Warranty, expressed or implied
whatsoever, even if the loss or damage is caused by the Company’s
negligence or fault. Some states do not allow the exclusion or limita-
tion of incidental or consequential damages, so the above limitation or
exclusion may not apply to you. This Warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
Please refer to insert for the Limitations of Fire Alarm Systems
to maintain electrical supervision. See
Figure 4
.
Figure 4.
BREAK WIRE AS SHOWN FOR
SUPERVISION OF CONNECTION.
DO NOT ALLOW STRIPPED WIRE
LEADS TO EXTEND BEYOND SWITCH
HOUSING. DO NOT LOOP WIRES.
A0337-00
The sounder has a set of input terminals to provide addi-
tional control of the sound output of the directional sounder.
These terminals can be connected to the dry relay contacts
of control devices such as heat sensors or control mod-
ules. When the input is active it will disable the sound out-
put of the Sounder. Connect the disable function as shown
in
Figure 5
. Refer to
Table 3
for function switch settings.
Figure 5.
– VDC
TO NEXT DEVICE
OR EOL
OPTIONAL DISABLE CONTACT
+ VDC
Mechanical
Two screws are included for attaching the sounder to the
electrical junction box.
NOTE:
If surface mounting is required, an extension ring
will be necessary to give proper depth for mounting the
sounder. The minimum depth required, in the backbox/
extension ring combination, is 2
1
/
4
˝. Any combination of
4˝ × 4˝ backbox and 4˝ × 4˝ extension ring that gives an
interior depth of at least 2
1
/
4
˝ may be used.
Mounting
See
Figure 6
. The sounder can be flush mounted on a
4˝ × 4˝ × 2
1
/
4
˝ back box, as follows:
A. Use the two 8-32 × 1
3
/
4
˝ screws (provided) to attach
the Sounder to the back box.
B. Plug the remaining two holes that will not be used
for attachment with the plugs provided.
Figure 6.
4" x 4" x 2-1/4"
BACKBOX
PF24V
8-32
SCREWS
FILL
PLUGS
Skirt, BBS-SP201W
A0359-00
A0929-00
4" x 4" x 2-1/4"
BACKBOX
PF24V
8-32
SCREWS
FILL
PLUGS
A0176-05