System Sensor B116LP Installation And Maintenance Instructions Download Page 4

D150-01-00

4

I56-599-03R

© 2001 System Sensor

Three-Year Limited Warranty

System Sensor warrants its enclosed smoke detector base to be free from
defects in materials and workmanship under normal use and service for a
period of three years from date of manufacture. System Sensor makes no
other express warranty for this smoke detector base. No agent, represen-
tative, dealer, or employee of the Company has the authority to increase
or alter the obligations or limitations of this Warranty. The Company’s
obligation of this Warranty shall be limited to the repair or replacement of
any part of the smoke detector base which is found to be defective in
materials or workmanship under normal use and service during the three
year period commencing with the date of manufacture. After phoning
System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return
Authorization number, send defective units postage prepaid to: System
Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St.

Charles, IL 60174. Please include a note describing the malfunction and
suspected cause of failure. The Company shall not be obligated to repair
or replace units which are found to be defective because of damage,
unreasonable use, modifications, or alterations occurring after the date of
manufacture. In no case shall the Company be liable for any consequen-
tial or incidental damages for breach of this or any other Warranty,
expressed or implied whatsoever, even if the loss or damage is caused by
the Company’s negligence or fault. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limita-
tion or exclusion may not apply to you. This Warranty gives you specific
legal rights, and you may also have other rights which vary from state to
state.

Please refer to insert for the Limitations of Fire Alarm Systems

Summary of Contents for B116LP

Page 1: ...ure Range 0 to 49 C 32 to 120 F US and Canadian Installations 10 to 60 C 14 to 140 F European Installations Operating Humidity Range 10 to 93 Relative Humidity Electrical Ratings includes base and detector System Voltage 24 VDC Maximum Ripple Voltage 4 Volts peak to peak Start up Capacitance 0 02µF Maximum Standby Ratings 15 VDC Minimum 35 VDC Maximum 120 µA Maximum Alarm Ratings 8 V Minimum at 16...

Page 2: ...l panel manufacturer s specifications for the total loop resistance allowed for the particular model control panel being used before wiring the detector loops Locate installations where normal ambient temperatures do not exceed 100 F Wiring Instructions For system supervision For terminals 2 3 and 5 do not use looped wire under terminals Break wire run to provide system supervision of connections ...

Page 3: ...ring diagram POWER LOOP 2 WIRE CONTROL PANEL POWER LOOP 3 2 4 5 1 12 13 14 COM CONTACT N C AUXILIARY N O FORM C E O L CLASS A OPTIONAL WIRING A78 1577 00 remove the detector from the base once the tamper resist ance feature has been activated place a small bladed screwdriver into the small hole on the side of the base and push plastic lever away from the detector head see Figure 3B This will allow...

Page 4: ... 800 SENSOR2 736 7672 for a Return Authorization number send defective units postage prepaid to System Sensor Repair Department RA __________ 3825 Ohio Avenue St Charles IL 60174 Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modification...