System Sensor warrants its enclosed smoke detector base to be free from 
defects in materials and workmanship under normal use and service for a 
period of three years from date of manufacture. System Sensor makes no 
other express warranty for this smoke detector base. No agent, represen-
tative, dealer, or employee of the Company has the authority to increase 
or alter the obligations or limitations of this Warranty. The Company’s 
obligation of this Warranty shall be limited to the repair or replacement 
of any part of the smoke detector base which is found to be defective 
in materials or workmanship under normal use and service during the 
three year period commencing with the date of manufacture. After phon-
ing System Sensor’s toll free number 800-SENSOR2 (736-7672) for a 
Return Authorization number, send defective units postage prepaid to: 

Please refer to insert for the Limitations of Fire Alarm Systems

Three-Year Limited Warranty

Honeywell, 12220 Rojas Drive, Suite 700, El Paso TX 79936 USA. Please 
include a note describing the malfunction and suspected cause of failure. 
The Company shall not be obligated to repair or replace units which are 
found to be defective because of damage, unreasonable use, modifications, 
or alterations occurring after the date of manufacture. In no case shall the 
Company be liable for any consequential or incidental damages for breach 
of this or any other Warranty, expressed or implied whatsoever, even if 
the loss or damage is caused by the Company’s negligence or fault. Some 
states do not allow the exclusion or limitation of incidental or consequen-
tial damages, so the above limitation or exclusion may not apply to you. 
This Warranty gives you specific legal rights, and you may also have other 
rights which vary from state to state.

  

I56-0338-010R 

 

 

©2016 System Sensor. 03-11

Summary of Contents for 1451

Page 1: ...eak to peak Start up Capacitance 0 02 µF Maximum 0 02 µF Maximum Standby Ratings 8 5 VDC Minimum 15 VDC Minimum 35 VDC Maximum 35 VDC Maximum 120 µA Maximum 100 µA Maximum Alarm Ratings 4 2 VDC Minimum at 10 mA 4 2 VDC Minimum at 10 mA 6 6 VDC Maximum at 100 mA 6 6 VDC Maximum at 100 mA Reset Voltage 2 5 VDC Minimum 2 5 VDC Minimum Reset Time 0 3 Seconds Maximum 0 3 Seconds Maximum Start up Time 3...

Page 2: ... system control panels have specifications for allowable loop resistance Consult the control panel manufacturer s specifications for the total loop resistance allowed for the control panel being used before wiring the detector loops Wiring Instructions CAUTION Do not loop wire under terminals Break wire run to ensure supervision of connections Wire connections are made by stripping about 3 8 of in...

Page 3: ...ion C0529 00 2 3 4 1 REMOTE ANNUNCIATOR 2 3 4 1 REMOTE ANNUNCIATOR 2 WIRE CONTROL PANEL E O L CLASS A OPTIONAL WIRING tant tab before installing the detector see Figure 3A The tamper resistant tab is on the detector mounting base To remove a tamper resistant detector from the base use a pocket screwdriver or similar tool to depress the tamper resistant tab and turn the detector counterclockwise Th...

Page 4: ...end defective units postage prepaid to Please refer to insert for the Limitations of Fire Alarm Systems Three Year Limited Warranty Honeywell 12220 Rojas Drive Suite 700 El Paso TX 79936 USA Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use ...

Reviews: