background image

Summary of Contents for INT100

Page 1: ......

Page 2: ...OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS OF DIGITAL APPARATUS MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS THE INFORMATION IN THIS MANUAL IS BELIEVED TO BE ACCURATE AS OF THE DATE OF PUBLICATION IDIS CO IS NOT RESPONSIBLE FOR AN...

Page 3: ...ent during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the equipment due to lightning and power line surges 11 Overloading Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock 12 Objects and Liquids Never ...

Page 4: ...n 1 Connection via LAN 2 Connection via Dial up Modem How to Use INT100 1 INTBase100 INT100 Browser 2 INT100 Administration Page Appendixes 1 Technical Specifications 2 Troubleshooting 05 07 07 11 12 12 17 26 26 27 Table of Contents ...

Page 5: ...nt when published The manufacturer reserves the right to revise and improve its products All specifications are therefore subject to change without notice Important Information Before proceeding please read and observe all instructions and warnings contained in this manual Retain this manual with the original bill of sale for future reference and if necessary warranty service INT100 User Manual 4 ...

Page 6: ...gorithm Low network bandwidth requirement 3KB per image typical Three levels of input resolution 640x480 320x240 160x120 Four levels of image compression B Simultaneous video and audio signal transmission Monitor voices and background sounds via one audio input C Supports various network environments Ethernet or Fast Ethernet interface for Internet Modem interface for standard telephone lines D Ea...

Page 7: ...tallation Diskette for Modem Connection MINIDIN 8 DB 9 Converter for Modem Connection User Manual 4 Monitoring System Requirements OS Microsoft Windows 98 CPU Intel Pentium II Celeron 266MHz or higher RAM 32MB or higher VGA AGP Video RAM 4MB or higher Web Browser Internet Explorer 5 0 or higher version ...

Page 8: ...wer cable to the appropriate port on the back panel The INT100 has been booted normally if POWER LED blinks once within 10 seconds 1 3 PC Setup Use a PC that can network with the INT100 without a router From now on this particular PC will be referred to as PC Video Out INT100 Back Panel INT100 Front Panel Network Installation I O Port Power Jack RS232 Reset Audio In Video In ...

Page 9: ...the TCP IP and then click Properties Modify your network configuration as shown below Make a note of the existing network configuration values since you will need to restore them in Step 1 8 Note You may need to reboot after this step Example IP Address 192 168 1 150 In fact fourth address may be any value from 1 to 254 except 129 Subnet Mask 255 255 255 0 ...

Page 10: ...If the ping utility returns Reply from 192 168 1 129 it means that the address has been set and communication is established If the ping utility continually returns Request timed out go back to Step 1 2 and try again 1 6 Administrator Configuration Start your Web browser and enter http 192 168 1 129 admin_login html in the location address field The INT100 Administrator Login Page will appear Ente...

Page 11: ...has completed the new network configuration Refer to the INT100 Administration Page section for details 1 8 Restoring PC Network Configurations Restore the network configurations to the original values in Step 1 4 You may need to reboot 1 9 Verifying Networking Run the ping utility again with an IP address modified in Step 1 7 In case the networking does not work disconnect and reconnect the power...

Page 12: ...the INT100 executes a modem initialization command and makes the modem ready to receive a call 2 3 Installing a Browser for Modem Connection Another modem should be installed in a local PC which will be connected via modem to the INT100 at a remote site From now on this particular PC will be referred to as PC Insert a supplied installation diskette to the PC and install the INTBase100 by running s...

Page 13: ... date time and alarm status Utility Buttons Selects a camera and functions including connection disconnection audio on off image adjustment and PTZ control Screen Enlargement Shrink Button Selects a screen size 640x480 320x240 160x120 Title Bar Displays the title of the location where the INT100 is installed How to Use INT100 Opens closes the window for PTZ control Opens closes the window for imag...

Page 14: ...alled The camera title can be changed on the Administration Page Refer to the Administration Page section for details Transmission Status Displays the image size in bytes the number of images per second and the data transmission rate in Kbps No Video No Video is displayed in the center of the camera screen when there is no input signal from a camera Not Activated Not Activated is displayed in the ...

Page 15: ...INT100 User Manual 14 1 3 Image Adjustment Brightness Contrast Saturation Hue Revert Cancels the image processing operation and reloads the original image 1 4 PTZ Control Pan Tilt Zoom In Out IRIS Focus ...

Page 16: ...delete and press Delete Up to ten sites can be registered in this phonebook In case of adding connection sites press Add and enter site ID and its phone number And then press OK The site ID and telephone number can be added edited or deleted by pressing and selecting Setup 1 5 Dialog Boxes for Dial up Connection The following dialog box appears after executing the shortcut icon for modem connectio...

Page 17: ...e Help menu of OS running on your PC for detail instructions on setting up the modem 1 6 Administration Dialog Box for Modem User The INT100 administration dialog box is available only if you log in as an administrator with an administrator s ID After administrator login has been successful double click the title bar of the INTBase100 The following dialog box will appear Press Show modem and check...

Page 18: ...he Password is 12345 The INT100 Administration Page will be displayed if login is successful The INT100 Administration Page has eight sections System Management User Account Management Network Configuration Connection Management Digital IO Configuration Serial Port Configuration Camera Configuration and PTZ Configuration Additional sections include System Upgrade System Reboot Connection Monitorin...

Page 19: ... the default settings of INTBase100 when the user first accesses the system Window Size 640x480 320x240 or 160x120 Audio On Off and Guest Login If the Default Guest Login box is unchecked then only registered users who completed the login procedures can use the system Refer to the User Account Management section for the user registration The sample System Management and INTBase Launch Option setti...

Page 20: ...lling the INT100 to prevent others from changing the settings If you forget an administrator ID and password launch Factory Reset using the default ID admin and password 12345 Refer to the Appendix II Troubleshooting for details To register additional users enter their user IDs under Login ID and passwords under Password and then confirm the password under Re Password Then click Submit If you want...

Page 21: ...ed from your network administrator Click Submit When the network configuration is changed the system will reboot automatically and save the new settings If wrong setting values are registered you will not be able to access the rebooted INT100 and will have to launch Factory Reset Refer to the Appendix II Troubleshooting for the instructions on Factory Reset ...

Page 22: ...e transmission speed in fps camera status audio status and the time they connected For example the information in the box above illustrates that the user named guest User ID guest accessed the server from IP address 192 168 1 150 IP Address 192 168 1 150 on Friday April 24th 2001 at 21 38 47 Connection Time Since Fri Apr 21 38 47 2001 with the connection number 0 Num 0 Camera images CAM 1 are bein...

Page 23: ...ess assigned to that camera The INTBase100 warning lamp also indicate the state of a sensor closed or open The sensing condition is set when a target sensor port and a ground port on the back panel are connected Normally Closed and when a target sensor port and a ground port are not connected Normally Open There is one dry contact open collector alarm output which can control the switch of an exte...

Page 24: ...deo channel state the administrator can set the state of image transmission regardless of the camera connection Not Activated will be displayed on the camera screen of the INTBase100 when the user selects Off for Video Channel State Image resolution and the image quality level need to be adjusted properly because they affect image quality and transmission speed The image resolution is the size of ...

Page 25: ...anufactured by IDIS already has a terminal resistor inside Refer to the manual for each supported driver for the detailed communication settings between the INT100 and the PTZ module 2 9 System Upgrade This page allows software upgrades to be done at remote sites using a web browser so that users do not have to come to the INT100 or take its cover off Since wrong software upgrades may cause an unr...

Page 26: ...ator does not need to click this menu to get the updated information Connection Statistics Monitoring shows the current system version bootstrap time system status system time number of connected users and average frames per second The Currently Connected Users information is the same information as the Current Connection Statistics in Connection Management 2 11 Log Out Please log out after finish...

Page 27: ...1 ch NTSC PAL NTSC PAL Autosensing Selectable from 640 x 480 320 x 240 160 x 120 ML JPEG or JPEG Programmable Compression Ratio Max 30 frames sec Max 25 frame sec PAL 1 ch Web Browser Active X or Monitoring S W Alarm In Alarm Out 150 x 44 x 106 mm 0 6 kg Video Input 1 Vp p 75Ohm Comp 1 ch Video Output 1 Vp p 75Ohm Comp 1 ch Loop Through Audio Input LAN 10 100 Base T Ethernet I F Serial Port RS 232...

Page 28: ...e administrator account so I cannot log into the INT100 Adiminstration Page A After launching Factory Reset use the default ID admin and password 12345 The network configuration returns to the factory default settings after launching Factory Reset Reset the settings by following the installation procedures in this manual Q The INTBase does not launch A Upgrade Internet Explorer to 5 0 or higher ve...

Reviews: