background image

 11

Chapter 3 — Specification 

3.1 Equipment Specification 

 

GENERAL 

 

Regulatory Conformity 

FCC, CE,

 

R

o

HS

 

ELECTRICAL 

 

Input Voltage 

12 VDC 

Power Consumption 

3W 

Communication

  

RS-485 

BNC Video Input

 

Connection camera video port(1Vp-p  75 Ohm unbalanced) 

BNC Video Output

 

To Monitor BNC port(1Vp-p  75 Ohm unbalanced) 

MECHANICAL 

 

 

Dimension

  

13.79x4.75x1.73 (Unit : inch) / 350x120.5x44 (Unit : mm)   

  

Unit Weight 

Approx. 44.80 (Unit : oz) / 1.27 (Unit : kg)  

Shipping Weight 

Approx. 75.14 (Unit : oz) / 2.13 (Unit : kg)  

Shipping Size 

19.88 x 8.46 x 6.69 (Unit : inch) / 505 x 215 x 170 (Unit : mm)  

ENVIRONMENT 

 

Operation Temperature

  

0

°

C to 35

°

C (32

°

F to 95

°

F) 

Operating humidity 

10% to 90%RH (non-condensing) 

Storage temperature 

-20

°

C to 60

°

C ( -4

°

F to 140

°

F) 

Specifications are subject to change without notice.

 

 
 
 
 

3.2 Signal Strengths by Video Cable Types 

 

Refer to the chart below for the minimum cable requirements and the maximum cable distance 

by cable types. 
 

 

Minimum Cable Requirements 

- 75 ohms impedance 
- All copper center conductor 
- All copper braided shield with 95% braid coverage 

 

Cable Types 

Maximum Distance 

RG59/U 750 

ft(228m) 

RG6/U 1000 

ft(304m) 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 8CH FX-TRON

Page 1: ...8CH FX TRON Instruction Manual Please read this manual thoroughly before use and keep it handy for future reference Rev 110308 ...

Page 2: ... REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE DO NOT INSERT ANY METALLIC OBJECTS THROUGH THE VENTILATION GRILLS OR OTHER OPENINGS ON THE EQUIPMENT CAUTION EXPLANATION OF GRAPHICAL SYMBOLS ...

Page 3: ...ENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE CAUTION CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS CLASS A DIGITAL APPARATUS COMPLIES W...

Page 4: ...eptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when u...

Page 5: ...Rear 6 1 2 2 Dip switch Configurations Settings 7 CHAPTER 2 INSTALLATION 9 2 1 System Connection and Operation 9 2 2 Camera Configuration with Keyboard 10 CHAPTER 3 SPECIFICATION 11 3 1 Equipment Specification 11 3 2 Signal Strengths by Video Cable Types 11 3 3 Dimensions 12 3 4 Package Contents 12 ...

Page 6: ...controller 5 baudrate supported 2400 4800 9600 19200 38400 bps 4 protocol supported to each channel independently Fastrax2 Fastrax2E Pelco P Pelco D 12VDC power 19inch rack mount 1 2 System Configuration 1 2 1 Front Rear Figure 1 Front Rear Front POWER Power LED CH1 8 Activated channel display LED Rear CAM Camera BNC input CH1 8 MON Monitor BNC output CH1 8 RS485 SETUP 4 pin dip switch setup RS485...

Page 7: ...8400 bps ON OFF OFF The baudrate on the FX Tron box must correspond to that of the keyboard controller for proper communication Setup baudrate refer to Table 1 Default setting is 9600bps Table 2 RS485 answer enable Dip Switch OFF ON 4 ANSWER No alarm answer Receive alarm answer Set the switch to ON to receive alarm answer from FX Tron box Only Fastrax2 and Fastrax2E protocol support answer Default...

Page 8: ...ON OFF 16 OFF ON ON ON ON 32 ON ON ON ON ON Table 4 Camera ID definition FX Tron ID Camera ID CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 1 1 2 3 4 5 6 7 8 2 9 10 11 12 13 14 15 16 3 17 18 19 20 21 22 23 24 4 25 26 27 28 29 30 31 32 5 33 34 35 36 37 35 39 40 31 241 242 243 244 245 246 247 248 32 249 250 251 252 253 254 255 256 Note ID of PELCO protocol camera is based on P address For example if D address is ...

Page 9: ...necessary to configure CAMERA of keyboard Configure Pelco protocol camera refer to chapter 2 2 3 Connect keyboard RS485 port and FX Tron RS485 port 4 Connect camera video output to CAM of FX Tron box 5 Connect MON of FX Tron to monitor 6 Select camera ID CAM key and control PTZ camera with keyboard 7 FX Tron box s front led displays current selected camera channel Note Turn FX Tron power off befor...

Page 10: ...this time the F2E protocol could not be changed To add the other camera 1 Select the blank line by moving the joystick down or up 2 Twist the handle of the joystick clockwise then the next camera number displays or press camera number and CAM key if that number is not already defined the camera number displays 3 Set the appropriate protocol and port moving the cursor by the joystick Alarm check op...

Page 11: ...rox 75 14 Unit oz 2 13 Unit kg Shipping Size 19 88 x 8 46 x 6 69 Unit inch 505 x 215 x 170 Unit mm ENVIRONMENT Operation Temperature 0 C to 35 C 32 F to 95 F Operating humidity 10 to 90 RH non condensing Storage temperature 20 C to 60 C 4 F to 140 F Specifications are subject to change without notice 3 2 Signal Strengths by Video Cable Types Refer to the chart below for the minimum cable requireme...

Page 12: ...ure 3 Dimension 3 4 Package Contents The package contains the following DESCRIPTION Q ty FX tron Box 1 Instruction manual 1 12VDC Power supply 1 19inch rack mount 2 Machine Screw FC2x6 10 Machine Screw M5x10 4 Rubber Foot 4 ...

Reviews: