CAN – Ethernet Gateway
18
©
SYS TEC electronic GmbH 2007 L-1032e_9
ipcfg
192.168.10.117 255.255.255.0 192.168.10.1
•
Set the CAN bitrate and the CAN identifier for error messages,
(refer to section 4.2.4)
for example: to 125 kBit/s and CAN identifier 0x81
/if/can0 baud:4 canid:81 on
•
Save the configuration file under a different name,
for example
UdpServer_1CAN_117.txt
The generated configuration file is written to the CAN-Ethernet
Gateway as follows:
1.
Change to the directory
/save
/ >cd /save
↵
/save >
2.
Erase the existing configuration file
rc
/save >rm rc
↵
/save >sync
↵