background image

 

SYSR86N Standard TCP/IP Reader Operation Manual 

 

 

 

I V.

 

Netw ork Mode Sw itch 

86N series device support 4 network modes:  Dual mode

ETH(Ethernet)

Wi-Fi AP

Wi-Fi client. 

Default Ethernet 

(DHCP) + Wi-Fi AP mode 

ETH-SERI AL 

Ethernet only

(

Factory Default

)

WI FI (CLI ENT)-SERI AL  Wi-Fi client mode 

WI FI (AP)-SERI AL 

Wi-Fi AP mode 

 

1.

 

ETH-SERI AL

Factory default is

 ETH- SERI AL. (  Standard TCP/ I P Reader )

 

When user modify the I P and click on Apply button, device will reboot and apply the setting after 30 

seconds.  

 

Summary of Contents for SYSR86N-HBX1

Page 1: ...SYSR86N HBX1 Standard TCP I P Reader Manual Version 01 04 2016 04 25 ...

Page 2: ...NTAG203 DESFire Card Read Range 1 5 cm Ethernet 10 100 base T Ethernet Wi Fi 802 11 b g n Black White List 500 Event Log 1180 Baud Rate 19 200 bps 4 800 230 400 bps Read Card Time 0 1 second Keypad 1 Key Capacitive Touch IR Sensor 1 IR Sensor adjustable range 0 10 cm Status Indicator Tricolor LED RGB Touch Status Indicator Tricolor LED RGB Interface Ethernet Wi Fi Wiegand RS 485 USB Device ID 0001...

Page 3: ...SYSR86N Standard TCP IP Reader Operation Manual 2 I I Wiring Diagram ...

Page 4: ...ion Manual 3 I I I Network Parameter Setting 1 Execute NET_Discover_V0110 exe and press to search SY86N series product 2 Factory default IP is 192 168 1 101 User can check the MAC address from product sticker with IP to confirm the device ...

Page 5: ...SYSR86N Standard TCP IP Reader Operation Manual 4 3 Double click IP 192 168 1 101 to open the web configure page http 192 168 1 101 Default login I D Password admin admin ...

Page 6: ...as the following User can modify Net Mode and other parameters If device cannot communicate properly after setting user can reset NET module via Micro USB Communication Parameter Factory Default Serial Configure 230400 8 n 1 Serial Framing Length 1050 Locale Remote Port Number 5001 ...

Page 7: ...i Fi AP Wi Fi client Default Ethernet DHCP Wi Fi AP mode ETH SERI AL Ethernet only Factory Default WIFI CLIENT SERIAL Wi Fi client mode WIFI AP SERIAL Wi Fi AP mode 1 ETH SERI AL Factory default is ETH SERI AL Standard TCP I P Reader When user modify the IP and click on Apply button device will reboot and apply the setting after 30 seconds ...

Page 8: ... one to connect But user cannot scan the AP after changing default network mode Ethernet only to Wi Fi Client 86N need to power off on to enable the scan function Encrypt Type Select Encrypt type for AP connection Password Enter password for AP I P Type DHCP is default mode If user have to setup a static IP please select Static PS Wi Fi MAC address is Ethernet MAC subtract 1 Ex Ethernet MAC AC A2 ...

Page 9: ... Point for client device to communicate This mode is usually for setting device SSI D Setup 86N device s SSID Encrypt Type Select Encrypt Type for the AP Password Setting 86N device s Wi Fi password I P address Setting 86N device s Wi Fi IP address Subnet Mask Setting 86N device s Wi Fi subnet mask ...

Page 10: ...TCP IP Reader Operation Manual 9 4 Default mode Ethernet DHCP Wi Fi AP mode It s Dual Mode Ethernet and Wi Fi AP but Ethernet only support DHCP SSI D Setup 86N device s SSID Password Setting 86N device s Wi Fi password ...

Page 11: ...tion Manual 10 V USB Connection Setup 86N parameter via Micro USB 1 Install USB driver CDC_USB_Driver_VCP_V1 4 0_Setup exe 2 System will generate a virtual COM port For example Check port in device manager below picture is COM 3 Micro USB ...

Page 12: ...iver manually The driver is saved in the folder that is same as following 3 Get device Model information and serial number by using V7 Tools with correct COM port 4 V7 Tools also provides Ethernet mode User only needs to fill in correct IP and Port and click to setup 1 2 3 4 ...

Page 13: ...ot 86N Initial Restore 86N to factory default It is NOT including network setting NET Initial 6 sec Restore network parameter of 86N to Default mode User has to setup by referring the following information after restore device to factory default Communication Parameter Factory Default Serial Configure 230400 8 n 1 Serial Framing Length 1050 Locale Remote Port Number 5001 ...

Page 14: ...t is 30 x 10ms I SO14443A B I SO15693 Same Card Delay Setup time gap for reading the same card default is 10 x100ms 1 second Green Mode Slow down the card read speed to power saving Reset Reset RF IC after read card Card Type Choose card type to enable 86N read specific card UID A Read ISO14443A Card UID Block Read Block data Must disable other card type UID B Read ISO14443B Card UID GUID B Read t...

Page 15: ...dicator will turns red in the period Off Turn off read card function Touch Key Setup output mode when Touch Key is triggered I R Sensor Setup output mode when IR is triggered I R Power Setup IR sensor power It s related working range 100 is farthest 10 is closest 3 86 Series Bluetooth Bluetooth Mode Setup receiving mode for Bluetooth signal Auto Receive Bluetooth signal automatically IR Sensor Rec...

Page 16: ...e shortest read range RSSI Adjust RSSI level 0 250 to filter TAG which have low RSSI signal in reader Ex Set RSSI Level to 120 Reader will receive tag which RSSI are stronger than 120 5 86 Series DI DO Mode DI DO Mode Setting RS485 Mode Communication interface have to switch into RS485 DO1 Setup DO1 motion parameter RS485 Control DO1 motion via RS485 Touch Key To activate DO1 by using touch panel ...

Page 17: ...tting Wiegand Mode Communication interface have to switch into Wiegand DO1 Setup DO1 motion parameter Touch Key To activate DO1 by using touch panel keypad IR Sensor To activate DO1 by using IR sensor Touch Key or IR Sensor To activate DO1 by using touch panel keypad OR IR sensor Default MESSAGE Setup contact motion mode LEDGI MESSAGE contact is grounding reader indicator green on Default LEDRI ME...

Reviews: