6.  Set reader mode to Wiegand or RS485 

 

 

7.  Factory Default: All setting will set factory default. 

 

 

8.  Adjust RSSI level (0~250) to filter TAG which have low RSSI signal in reader. 

(This function was available in version 1.30 or above.)

 

 

Ex. Set RSSI Level to 120, Reader will receive tag which RSSI are stronger than 120. 

 

9.  Set Gain (1~7) to control reader’s read range. 

Level 7 is the max range (default setting), Level 1 is the shortest read range 

 

Summary of Contents for SYRD245-2U

Page 1: ...SYRD245 2U 2R 2S 2P 2 45 GHz Reader User Manual Version 1 4 2011 10 19 ...

Page 2: ...55 LQI 0 255 Programmable Set Parameter LED LED visual indication Interface SYRD245 2U USB SYRD245 2S RS232 RX TX SYRD245 2R 2P RS485 2P for SYRIS Controller Power Power Input 3 5 VDC 12 VDC 2R 7 VDC 18 VDC 2S 2P 5 VDC 2U Action Current 100 mA 5 VDC Environment Operating Temperature 20 o C to 65 o C 5 to 95 RH Storage Temperature 30 o C to 85 o C 5 to 95 RH Dimension 92W x 66H x 20D mm ...

Page 3: ...SYRD245 2 series 2 45 GHz active RFID Reader User Manual 2 Ⅱ The Diagram of the System Connection SYRD245 2 series can connect with 3 different interfaces USB 2U RS 232 2S RS 485 2R 2P ...

Page 4: ...m SYRD245 2R 2S 2P have no need install any driver just select correct port to connect with reader 1 Execute install program in SYRIS CD SYRIS Xtive CD ROM SYRD245 2 Driver 2 Reboot PC after the installation 3 When you finished install driver you can execute SYRIS Xtive Utility program to read TAG and set parameters Please refer to Xtive Utility user manual ...

Page 5: ...2 series 2 45 GHz active RFID Reader User Manual 4 Ⅳ Setting SYRD245 2P 1 Connect SYRD245 2P 4R and 4R to MD485 USB then connect to PC 2 Execute SYRIS Xtive DVD ROM SYRD245 2 Utility SYRD245_2P_Tools_V0183 exe ...

Page 6: ...r User Manual 5 3 Scan Reader to get reader s serial number and firmware version 4 Adjust the ID number and then click Set Reader ID to change Reader s ID 5 Select communication Baud rate and then click Set Baud rate to change Reader s Baud rate ...

Page 7: ...y default 8 Adjust RSSI level 0 250 to filter TAG which have low RSSI signal in reader This function was available in version 1 30 or above Ex Set RSSI Level to 120 Reader will receive tag which RSSI are stronger than 120 9 Set Gain 1 7 to control reader s read range Level 7 is the max range default setting Level 1 is the shortest read range ...

Page 8: ... function was available in version 2 03 or above This parameter should use with SYRIS exciter default values are 0000 means disable If this function enable reader will only receive tag s signal which include set exciter ID 11 Reader Reset Reset online reader Reader will warm restart ...

Reviews: