SYKD2N-H5/L5
Card Frequency
H5
:
13.56MHz(Multi-Format)
L5
:
125KHz(EM)
Keypad
13 Keypad(Capacitive)
Active RFID
Support 2.45GHz active RFID(option)
Interface
RS485 and Wiegand(26/32/34/35/37/42/66 Bit)
Ethernet / Wi-Fi
Ethernet
10M/100M Ethernet Port
Wi-Fi
802.11 b/g/n
Baud Rate
19,200 bps(4,800~230,400bps)
Capacity of Records
2000
Capacity of Cards
2000
Status Indicator
LED (RGB)
IR Sensor
1 IR sensor for waving hand.
Digital Input
Up to 3 (1 for non-voltage DI+2 for non-voltage DI share same port
with Wiegand)
Digital output
Up to 2 (2 Relay output)
Holiday Control
30 Day
Anti-duress PIN
4 Set
Anti-Tamper
/Anti-Lockup
Build-in(Infrared) / (Watchdog)
Voice output
Build-in Buzzer
Operating
temperature
-10
℃
~+60
℃
Input Voltage
8V ~ 28V DC / 1W ~ 6W
Dimension(W x H x D)
90(W) x 124(H) x 27(D) mm
Option
Description
Logout
Enter
#
+
#
+
0
+
0
(Beep)
Login
Enter
#
+
#
+
0
+
1
(Beep) +
【
Password
】
+
#
Note:
Default Password:
1234
;
Auto-logout after user login for 30
seconds and without doing any setting.
Please login device first before doing the following setup
ID
Enter
#
+
#
+
0
+
2
(Beep) +
【
ID
】
+
#
Note:
ID Range is 1~9999
;
(Default ID
:
1)
Date/Time
Enter
#
+
#
+
0
+
3
(Beep) +
【
YYYYMMDDhhnnss
】
+
#
Note:
For example, 2011/
01
/29
03
:25:
23
, please enter
2011
01
29
03
25
23
Login
Password
Setup
Enter
#
+
#
+
0
+
4
(Beep) +
【
New Password
】
+
#
Note:
Login password is 4 char (Default: 1234)
;
user can setup
factory default via computer software if user forgot the password.
Backlight Time
Enter
#
+
#
+
0
+
5
(Beep) +
【
Time
】
+
#
Note:
Time range is 0~250 second
s;
0 means always on(Default:30
Seconds)
Card Read
Mode
Enter
#
+
#
+
0
+
6
(Beep) +
【
S
】
+
#
Note:
Show Card Mode 0
:
None
、
1
:
Card No(Default)
、
2
:
UID
、
3
:
Char
Language
Enter
#
+
#
+
0
+
7
(Beep) +
【
Language
】
+
#
Note:
0
:
ENGLISH(Default)
、
1
:
CHT
、
2
:
CHS
Code Setting
Enter
#
+
#
+
0
+
8
(Beep) +
【
Encode
】
+
#
Note:
0
:
UNICODE(Default)
、
1
:
BIG5
、
2
:
GB2312
Shift Setting
Enter
#
+
#
+
0
+
9
(Beep) +
【
Class
】
+
#
Note:
0
:
Disable(Default)
、
1
:
Enable
Switch shift mode needs to operate under
shift setting mode
enabled
:
On Duty
:
#
+
【
1
】
(Beep)
;
Off Duty
:
#
+
【
2
】
(Beep)
Go Out
:
# +
【
3
】
(Beep)
;
Return
:
# +
【
4
】
(Beep)
Start Overtime
:
# +
【
5
】
(Beep)
;
Finish Overtime
:
# +
【
6
】
(Beep)
Add Card
A. Enter
#
+
#
+
1
+
1
(Beep) +
【
Card Number
】
+
#
+
Show Card+
*
B. Enter
#
+
#
+
1
+
1
(Beep) +
Show Card +
*
Note:
A.User can define specific card number (number from 1 to 2000).
B.System will assign card number automatically.
Delete Card
A.Enter
#
+
#
+
1
+
2
(Beep) +
【
Card Number
】
+
#
B.Enter
#
+
#
+
1
+
2
(Beep) +
Show Card +
*
Note:
A.User can define specific card number (number from 1 to 2000).
B.System will erase the showing card.
Card Password
Enter
#
+
#
+
1
+
3
(Beep) +
【
Password
】
+ # +
Show Card +
*
Note:
Showing card that will be created password
;
Password
contains 1 ~ 4 numeric code(After enabled card password function
,
it needs to work with door open mode)
Master Card
Setting
Enter
#
+
#
+
1
+
5
(Beep) +
【
M
】
+
#
+
Show
Card+
*
Note:
Enter master card number(card number is 1~3) then show
the card to device. (To login,user can use PIN code or master card
after pressing
##01
)
Erase All Cards
Enter
#
+
#
+
1
+
9
(Beep) +
【
Password
】
+
#
Note:
Login device before doing the procedure(Default Login
Password:
1234
)
Door Open
Time
Enter
#
+
#
+
2
+
1
(Beep) +
【
Time
】
+
#
Note:
Time range to open door is 0~255 secon
d;
0 means mode for
open one time close one time.
Note
Press to return the previous steps while doing
:
error input. Fast procedures to setup for access door by
using card or password.
A: ##01 Login
B. ##11 Add one card *
C. ##13 Setup password for this card *
D. ##23 →0 Switch access door with PIN only #
E. ##22 →1 Switch access mode as card or pin to access door #
F. Reboot