background image

ConnectionCenter 3228 All-in-one

Instructions for use

Summary of Contents for ConnectionCenter 3228 All-in-one

Page 1: ...ConnectionCenter 3228 All in one Instructions for use...

Page 2: ...nulate A conductivity sensor and pressure sensors are already in tegrated in the digital capacity control The built in pressure reducer ensures a constant set output pressure so that the heating syste...

Page 3: ...llowing elements or displays The display is switched off on delivery Press any key to switch the display on the version number is displayed and the remaining quantity of the standard set ting 1166 lit...

Page 4: ...calculated residual quantity in litres Note After each cartridge change the settings Raw water hardness cartridge Soft water hardness must be made again Set the desired mixed water hardness at the ble...

Page 5: ...ssure reducer of the Connection centre All in one is factory set to 1 5 bar Please note that the inlet pressure must be at least 1 bar higher than the desired outlet pressure The pressure reducer can...

Page 6: ...in accordance with DIN EN 806 part 5 to ensure that the backflow preventer works properly Remove the manometer plug of the inlet and intermediate pressure zone 1 2 Install the maintenance ball valves...

Page 7: ...echanical defect Open the needle valve 1 further and relieve the medium pres sure zone until it is completely drained Maintenance inspection of check valve 2 To test the outlet check valve RV 2 the in...

Page 8: ...ly and if necessa ry clean the cartridge with clear water Fixture for backflow preventer cartridge Fixture for screwed seat Use the replacement tool 6600 00 970 for removal Remove the cap Remove backf...

Page 9: ...30 litres cartridge 0 3 m3 h at Dp 1 5 bar 2 5 litres cartridge Maintenance pressure reducer Technical specifications Reassemble in reverse order Open the ball valves again Installation and maintenan...

Page 10: ...ominal size DN 20 A R Dimensions L mm 305 327 adjustable l mm 279 T mm 91 113 5 adjustable t mm 148 H mm 263 2 5 litre cartridge 365 4 litre cartridge 562 7 litre cartridge 1017 14 litre cartridge 922...

Page 11: ...venter cartridge complete 6600 00 974 3 Digital capacity control 3228 00 905 4 Pressure reducer cartridge 0315 15 900 Pressure sensor 3228 00 904 6 Blending valve complete 3200 15 914 7 Tundish comple...

Page 12: ...0 00 015 7 litre 3200 00 005 14 litre 3200 00 006 30 litre 3200 00 016 HWE 2 5 litre 3200 00 942 4 litre 3200 00 904 7 litre 3200 00 906 10 litre 3200 00 937 14 litre 2 x 7 litre 30 litre 3 x 10 litre...