background image

                                                         

Synway Information Engineering Co., Ltd

 

3.4 Recording Management 

Recording Management is used to manage the configuration concern with the recording data. 
Here it mainly contains 

Disk Management

, See Figure 3-11.  

 

Figure 3-11 Recording Management Interface 

3.4.1 Disk Management 

 

Figure 3-12 Disk Management Interface 

See Figure 3-12 for the disk management interface. The above list shows the information of all 
storable disks, including name, path, type, file format, total capacity, used capacity and available 
capacity. The table below explains the above items in Figure 3-12. 

Item 

Description 

Reserved Block 

Space of Each Disk 

Sets the available space size of the disk, with the default value of 20480. The value 

cannot be less than 20480MB. 

Byte Auto-deleted 

Part of the data will be removed automatically once the disk space is detected full by 

the recording server. Calculated by MB, with the default value of 1024. 

Update Database 

after Auto File 

Deletion 

Sets whether the recording server upgrades the database or not once a recording 

file is deleted. 

Saving Path 

Sets the path to save the recording data automatically. 

After configuration, click 

Save

 to save the above settings into the server. Click 

Reset

 to restore 

the configurations. 

3.5 User Management 

See Figure 3-13 for the User Management interface, which is used to manage the users who own 
the access authorities of the WEB as well as their authorities.   

SMG Series Recording Server User Manual (Version 1.0.0)

                                       Page 10 

Summary of Contents for SMGREC

Page 1: ...Synway SMG Series Recording Server SMGREC SMG Gateway Recording Server Version 1 0 0 Synway Information Engineering Co Ltd www synway net...

Page 2: ...3 3 1 Recording Query 7 3 3 2 Statistics Report 9 3 4 Recording Management 10 3 4 1 Disk Management 10 3 5 User Management 10 3 5 1 User Management 11 3 6 Authentication Management 12 3 6 1 Authentica...

Page 3: ...reserves all rights to modify this document without prior notice Please contact Synway for the latest version of this document before placing an order Synway has made every effort to ensure the accur...

Page 4: ...Revision History Version Date Comments Initial publication Version 1 0 0 2017 8 Note Please visit our website http www synway net to obtain the latest version of this document SMG Series Recording Ser...

Page 5: ...unication data on multiple digital gateways simultaneously 1 1 Typical Application Figure 1 1 Typical Application 1 2 Feature List Feature Description Support of query with single or multiple conditio...

Page 6: ...ntication Support of recording devices registration and authentication Security Description Admin Authentication Support admin authentication to guarantee the resource and data security Maintain Upgra...

Page 7: ...t you change the initial username and password via Change PW on the WEB interface as soon as possible after your first login For detailed instructions about changing the password refer to 3 7 1 Change...

Page 8: ...Figure 3 1 Figure 3 1 Login Interface The SMGREC server only serves one user whose original username and password are both admin And only the password can be changed after your login For detailed ins...

Page 9: ...d Figure 3 2 Main Interface 3 2 Homepage See Figure 3 3 for the home page interface which displays the operation information of the SMGREC server Figure 3 3 Homepage Interface SMG Series Recording Ser...

Page 10: ...untime Time of the SMGREC server keeping running normally after startup This parameter updates every 2s CPU Usage Rate Display the real time usage rate of CPU Current Memory Display the total memory t...

Page 11: ...the combination of multiple query conditions The table below explains the query items in Figure 3 6 Item Description Start Date Start Time End Date End Time Time period of the recording including tim...

Page 12: ...ations Figure 3 7 Recording Query Results The recording query results include Gateway Serial No Call Direction CallerID CalleeID Codecs Start Time Recording Length and Remarks of each recording item O...

Page 13: ...ength of the recording used as a condition to filter recoding files Three options Unlimited Longer than and Shorter than are available The default value is Unlimited which means there is no limit on t...

Page 14: ...lable space size of the disk with the default value of 20480 The value cannot be less than 20480MB Byte Auto deleted Part of the data will be removed automatically once the disk space is detected full...

Page 15: ...t be the existent one like admin New Password Login password of the user Confirm Password Enter the login password again Rec Query Refer to 3 3 Recording Query Only the users with this authority can d...

Page 16: ...urations on this interface are the same as those on the user info adding interface Figure 3 16 User Info Modification Interface To delete a user tick the checkbox before username in Figure 3 15 and cl...

Page 17: ...the digital gateway to connect the recording server Password Login password of the authentication account Confirm Password Enter the login password again After configuration click Save to save the ab...

Page 18: ...ions in the current page Inverse means to uncheck the selected items and check the unselected 3 7 Change Password See Figure 3 21 for the Change Password interface which provides the interface for the...

Page 19: ...m update and restart See Figure 3 23 for details Figure 3 23 System Settings 3 8 1 Management Figure 3 24 Management Parameters Setting Interface See Figure 3 24 for the Management Parameters interfac...

Page 20: ...logged operations are sorted by the descending order in operating time i e the newer the operation is the higher it will be ranked on the WEB page 3 8 3 Data Capture Figure 3 26 Data Capture Interfac...

Page 21: ...interface You can check and modify the configuration items of the recording server through this interface You can modify these configurations on the interface directly and then click Save to save the...

Page 22: ...ancel the uploading file Note that clicking Reset can only delete the selected update file but not cancel the operation of Update 3 8 6 Restart Figure 3 29 Service System Restart Interface See Figure...

Page 23: ...D R Center No 3756 Nanhuan Road Binjiang District Hangzhou P R China 310053 Tel 86 571 88860561 Fax 86 571 88850923 Wechat QR Code Scan the QR code below to add us on Wechat Technical Support Tel 86 5...

Reviews: