Channel Controls
The Quadrangle has four channels. Each one looks like this:
A: CV over Attack
● CV control over the Attack cycle of the envelope. The input signal is additive and
subtractive to to the physical position of the potentiometer.
D/R: CV over Decay/Release
● CV control over the Decay cycle of the envelope. The input signal mimics the pot range
and is additive and subtractive to to the physical position of the potentiometer.
EOA: End of Attack trigger output
● Sends a trigger when the envelope has completed the Attack portion of the cycle.
EOC: End of Cycle trigger output
● Sends a trigger when the envelope has completed its cycle.
ATTACK
● Sets the length of the Attack cycle. Minimum: ~2ms. Maximum: ~2 seconds.
DEC/REL: Decay/Release
● Sets the length of the Decay cycle. Minimum: ~2ms. Maximum: ~2 seconds.
LEVEL
● Controls the output voltage of the envelope, with a range of -5V to +5V. At 12:00, the
envelope sends zero volts. When turned fully toward the - symbol, it sends 0 to -5V.
When turned fully toward the + symbol, it sends 0 to +5V.