Synthesizers.com Q109 Manual Download Page 4

 

Q109  

Envelope Generator

 

 

Aug 2014 

Calibration and Testing 

This module requires no calibration. 
 
1. Turn the Attack, Decay and Release controls to 0. 
2. Apply a 10hz 10v PP square wave to the Gate input. 
3. View the output on an oscilloscope. 
4. Turning Attack clockwise should make a longer attack 
    section of the waveform. 
5. Turning Decay clockwise should make a longer decay 
    section of the waveform. 
6. Turning Sustain clockwise should make a higher sustain 
    level of the waveform. 
7. Turning Release clockwise should make a longer release  
    section. 
8. Remove the Gate input, set all controls to 0 except  
    Sustain to 10. 
9. Pressing the Gate button should cause the LED to come 
    on. 
 

PC Board Layout 

Power Connector 

 
6 pin .1” MTA type connector made 
by AMP.  Available from Mouser 
Electronics or Digi-Key.  Modules 
have a male PCB mount connector 
and cable harnesses have a female. 
 
Part Numbers: 
Female cable mount: #6404416 
Male PCB mount: #6404566 
 
Pinout:  
1 = +15v 
2 = key (pin removed) 
3 = +5v 
4 = gnd 
5 = -15v 
 
Not all voltages are used on all mod-
ules. 

J4   J5 