Status LEDs
PCIe IP Prototyping Kit Installation Guide
A.3
ARC SDP Board LEDs
describes the ARC SDP board status LEDs colors and the status they indicate.The following list
represents the color code for the supervision LEDs.
Green Red
Table A-3
ARC SDP Supervision LED State and Description
LED
Color
Description
+12 V
Indicates the 12 V power supply is switched on.
RESET
Indicates the ARC SDP board reset status.
Normal
operation.
Reset is active.
TEMP
Indicates the FPGA temperature status.
FPGA temperature is OK
FPGA temperature higher than 75 °C (167 °F). Switch OFF the board.
Blinking
FPGA temperature higher than 90°C (194 °F). Switch OFF the board.
DONE
Indicates the FPGA’s status.
FPGA configuration is complete.
FPGA configuration ongoing.
POWER
Indicates the power monitor’s status
The required voltage levels are within tolerance.
The required voltage levels are not OK.
TUNNEL0
Indicates the status of the AXI tunnel to the ARC CPU Card.
OK
Failure. Check the ARC CPU card connection to the ARC SDP board.
TUNNEL1
Indicates the status of the AXI tunnel to the HAPS system.
OK
Failure. Check the HT3 connection cable.