background image

21-EMBS2-INS A-1

 

 
 

 

 
 

 

 
 

SPECIFICATIONS 

 

Dim Control Max Load: 30 mA Source/Sink 

 

Radio Frequency: 2.4 GHz (IEEE 802.15.4) 

 

RF Transmission Output Power: +19dBM 

 

Operating Temperature: -40 to +80 C 

 

Operating Humidity: 10 to 90%, non-condensing 

 

Max D4i Drivers: Limited to a maximum of 6 D4i 
LED Drivers, any D4i LED Drivers >4 will need the 
power supply disabled.  

 

Dimensions: 2.25

”L x 

2.0

”W X .3”H 

 

(57 X 50.8 X 7.6 mm) 

 

MODELS 

 

EMB-S2 (Uses external antenna) 

 

EMB-S2-F (internal antenna) 

 

CAUTION

 

EMB-S2 controllers must be installed in accordance 
with national, state, and local electrical codes and 
requirements 
 

DESIGN CONSIDERATIONS 

Below are some recommendations for successful 
dimming using the EMB-S2. The dimming control wires 
are referenced as Dim+ and Dim-.  The dimming 
signals have a Maximum voltage of 10V DC. 

 

Use multi-strand 18 Gauge Wire for noise 
immunity and current capability 

 

Do not ground the dimming wire; this is a 
return signal and is critical for dimming 

 

Route dimming wires away from AC lines if 
possible 

 

Use connections with properly sized 
connectors 

 

Eliminate excess wire between fixtures; Line 
length will cause voltage drop 

 

Maximum of 4 LED Drivers per controller, 
consult Synapse Support if a greater ratio is 
needed. 

 

 
 
 
 
 
 
 

NEEDED MATERIAL 

 

u.FL Insertion Tool: 

Part Number U.FL-LP-IN 

from Hirose Electric (for EMB-S2 only) 

 

u.FL Extraction Tool: 

Part number U.FL-LP-N-2 

from Hirose Electric (for EMB-S2 only) 

 

u.FL Connector and 14mm bulkhead: 

A cable 

with a u.FL connector on one end and a female 
14mm bulkhead connector on the other end is 
required to route the signal from the EMB-S2 
through the fixture housing to an external 
antenna.  

 

Mounting Hardware: 

(1) #4 and M3 screws and 

standoff recommended

 

 

Antenna Kit:

 For available antenna options please 

refer to our latest documents located on our 

website.  

www.synapsewireless.com/documentation

 

 

INSTALLATION INSTRUCTIONS 

WARNING: TO AVOID FIRE, SHOCK, OR DEATH: 
TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE 

AND VERIFY THAT POWER IS OFF BEFORE WIRING! 

 
MOUNTING 

Secure with 1 #4 screw (

max diameter of .312 

inches) 

and standoff.  

 

1.

 

Mounting Options: 

Mount in an LED Fixture or a 

Troffer. For the EMB-S2, an external antenna 
utilizing a u.FL connector must be used to provide 
RF connectivity to the SNAP mesh network. 
 

2.

 

Place the EMB-S2 in desired location and secure it 
using #4 sized screw and stand-off using the 
mounting hole located in the center of the board. 
Prior to permanently mounting the EMB-S2, make 
sure the antenna is free of any objects within 3 in. 

of the internal or external antenna. 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 

 

Note: 

When installing the EMB-S2 into an enclosure, 

consideration of the internal or external antenna 
position and interference is required in order to provide 
the most optimum wireless signal strength. 

 
 

 

When installing the EMB-S2 into an enclosure, 

consideration of the external antenna position and 
interference is required in order to provide the 
most optimum wireless signal strength. Prior to 
permanently mounting it, make sure the antenna 
points directly upward or downward and is free of 
any metal objects within 12 in. of the antenna 
(Figure 1).   

 

 

 

 

 

 
 

 

 

 

 

 

Figure 1 - Proper External Antenna Installation 

 

 
 
 
 
 
 
 

WARNING AND CAUTIONS: 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 AT CIRCUIT BREAKER 

OR FUSE AND TEST THAT POWER IS OFF BEFORE INSTALLING! 

PROPER GROUNDING REQUIRED TO AVOID STATIC DISCHARGE WHICH 
CAN DAMAGE CONTROLLERS DURING INSTALLATION.

 

 

 

EMB-S2 Controller

 

Load Ratings: 12 to 24VDC, +/-10%, 700mW max  

Operating Temperature: -40 to +80 C / Operating Humidity: 10 to 90%, non-condensing 

 

WARNING AND CAUTIONS:

 

If you are unsure about any part of these instructions, consult an electrician; all 
work should be performed by qualified personnel. 

Disconnect power at circuit breaker or fuse when servicing, installing or removing 
fixture or changing lamps. 

 

INSTALLATION GUIDE 

 