Symmons SAFETYMIX VISU-TEMP Installation, Operation & Service Instructions Download Page 1

Single Handle Pressure-Balancing Mixing Valve for Shower or Tub/Shower Application

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

8"

204mm

4 3/4"

119mm

approx.

35 3/8"

899mm

approx.

42"

1067mm

Ø 1/4”

57mm

NOTE: 2-1/2” (64mm) min.

3” (76mm) max. On 2”x4” con-

struction, use 2-1/2” (64mm) 

min. rough-in.

Valve inlets and outlets are 

1/2” (13mm) IPS connections.

Symmons valves, shower heads 

and hand sprays comply to all 

known standards, codes and 

specifications: CSA B-125, ANSI 

A-112.18.1M, ASSE 1016, EPA ‘92 

etc. Symmons shower heads and 

hand sprays are equipped with a 

2.5 gpm (9.5 L/min) water and 

energy saving flow restrictor.

This instruction sheet shows rough-in 
dimensions for Models 4-5000VT(X),  
1-1000VT(X) and 1-2100VT(X). See 
separate drawings enclosed with 
numbered models for applicable 
rough-in dimensions.
Tools required for installation of this 
product are: Phillips screw driver, 
tubing cutter, teflon tape, soldering 
equipment, adjustable wrench and 
channel-lock pliers.

Installation of Shower System 
Model 1-1000VT(X) (Figure 2)

Install HOT on left and COLD on right 
according to valve markings.

1.  Install piping and fittings with valve 

body as shown in Figure 2 or 3. 
IMPORTANT: Valve rough-in is 2-1/2” 
(64mm) min. — 3” (76mm) max. from 
CENTERLINE OF SUPPLIES TO FACE 
OF FINISH WALL. Install so that surface 
indicated on plaster shield on valve 

is flush with finish wall as shown in 
Figure 1.

2.  When finishing tile wall REMOVE 

(pull off; don’t turn) ENTIRE PROTEC-
TIVE PLASTER SHIELD and FILL AREA 
AROUND VALVE BODY WITH GROUT 
OR PLASTER. DO NOT PLASTER OVER 
SC-2 CAP OR SERVICE STOPS IF SO 
EQUIPPED. 

3.  Turn on hot and cold supplies, valve 

will not operate unless both hot and 
cold water are turned on.

4.  This valve is equipped with a limit stop 

screw to be used to limit valve handle 
from being turned to excessively hot 
water discharge temperatures. To 
adjust, remove dome cover (SC-
13/18), place handle (VT-112) on 
stem, open valve to maximum desired 
temperature and turn in limit stop 
screw (SC-26) until it seats. WARNING: 
Failure to adjust the limit stop 
screw properly may result in serious 
scalding. WARNING: This shower 

finish wall face

2

3" 76mm max.

64mm min.

1

2

''

supplies

CL

plaster shield

4

1

4

''- 4  "

108mm
114mm

1

2

FIGURE 2

Model 1-1000VT(X) Shower System

FIGURE 1

All floor to center dimensions optional. Concealed piping  and fittings not furnished by manufacturer.

For California Residents

WARNING:

 

This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

Reviews: