Symmons Origins S-9601P-RP Operation & Maintenance Manual Download Page 1

Origins

®

Operation & Maintenance Manual

S-9601P-RP, S-9601-XP-RP

Specification

Warranty

Limited Lifetime

 - to the original end purchaser in 

consumer/residential installations..
Refer to www.symmons.com/warranty for complete 
warranty information.

Model Numbers

S-9601P-RP

Origins Shower System

S-9601-XP-RP

Origins Shower System with integral service stops to 
allow water shutoff at valve for service

Compliance

-ASME A112.18.1/CSA B125.1

S-9601P-RP / S-9601-XP-RP

Shower system powered by the Temptrol

®

 Pressure 

Balancing valve. Features adjustable stop screw to limit 
handle turn, integral service stops to allow water shutoff at 
valve for service (S-9601-XP-RP only), integrated volume 
control, 1 mode showerhead with easy to clean rubber 
nozzles and standard 2.5 gpm (9.5 L/min) flow restrictor. 
Components made from metal and nonmetallic materials 
plated in standard polished chrome finish.

Measurements

A

6-3/8", 162 mm

B

3-1/2", 89 mm

C

2-7/8", 73 mm

D

Shower Valve Hole Size

Min. Ø 3", 76 mm

Max. Ø 4", 102 mm

E

Ref. 77", 1956 mm

F

Rough-in

2-3/8" ± 1/2", 60 mm ± 13 mm

G

Ref. 42", 1067 mm

H

Ø 2-1/2", 64 mm

I

Ø 2-3/4", 70 mm

J

2-1/8", 54 mm

K

Ø 5-3/4", 146 mm

FLOOR

FLOOR

EE

G

G

A

A

H

H

II

C

C

B

B

FF

K

K

JJ

D

D

Notes:

1) All dimensions measured from nominal rough-in (see F as reference).

2) Dimensions subject to change without notice.

Dimensions

Summary of Contents for Origins S-9601P-RP

Page 1: ...ew to limit handle turn integral service stops to allow water shutoff at valve for service S 9601 XP RP only integrated volume control 1 mode showerhead with easy to clean rubber nozzles and standard...

Page 2: ...ter Supply COLD Water Supply B C D E F I F G H J Parts Breakdown Notes 1 Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall Leave opening on bottom o...

Page 3: ...vertical shower pipe Turn clockwise to tighten B 1 2 C Installation note For valve body installation please see valve body manual Note Handle should be facing the 12 o clock position 6 Install showerh...

Page 4: ...ubleshooting Chart Problem Cause Solution Finish is spotting Elements in water supply may cause water staining on finish Clean finished trim area with a soft cloth using mild soap and water or a non a...

Page 5: ...a con un tornillo con tope ajustable para limitar el giro de la manija un regulador integrado del caudal de agua una cabezal de ducha de 1 funci n con boquillas de goma f ciles de limpiar y un restric...

Page 6: ...I F G H J Suministro de agua FR A Suministro de agua CALIENTE Desglose de piezas Herramientas requeridas Llave inglesa Llave Allen 1 8 Destornillador phillips Cinta de tefl n Silicona Notas 1 Aplique...

Page 7: ...jas del reloj para ajustarlos B 1 2 C Nota Para instalar el cuerpo de la v lvula vea el manual Nota El mango debe situarse en la posici n de las 12 6 Instale el cabezal de ducha A al brazo de la ducha...

Page 8: ...as en el suministro de agua pueden provocar que el agua manche el acabado Limpie el rea con acabado con un pa o suave usando jab n suave y agua o un limpiador no abrasivo y luego enjuague r pidamente...

Reviews: