Symmons DURO ACTIVESENSE S6360B Installation And Maintenance Manual Download Page 7

10

11

MAINTENANCE

FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel filter preventing foreign particles to enter the lines. It 
is recommended to clean the filter every six (6) months. If the water flow has decreased, this can be 
because the filter is clogged. The filter can be cleaned as follows:
1. Shut-off the water shut off valve (angle valve).
2. Disconnect the flexible pipe/s.
3. Remove the filter(s) and wash it/them under running water.
4. Reassemble the parts.
5. Make sure that there is no water leakage.

CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of 
any prohibited cleaning or maintenance products or substances could damage the surface of the 
faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry with clean cloth or 
towel. When cleaning bathroom tile, the faucets should be protected from any splattering of harsh 
cleansers.

SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires  periodical cleaning every six (6) months. Remove the 
diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged, wash it under 
running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic solenoid valves.

SPARE PARTS LIST  

Seals and screws kit

SF280

Solenoid valve kit

SF253

Filter

SF263

Battery box (batteries excluded)

SF258

12V switching transformer

SD010

SD010
12V Switching Transformer

SF258
Battery box 

SF280
Seals and Screws kit

SF253

Solenoid valve kit

SF263
Filter

Summary of Contents for DURO ACTIVESENSE S6360B

Page 1: ...INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE S6360B E S6360BM EM DURO ACTIVESENSETM ELECTRONIC LAVATORY FAUCET ...

Page 2: ... trademarks logos and service marks presented in this document including their design are the property of the manufactureror other third parties and you are not permitted to use them without the prior written consent of the manufacturer or such third party as may own them 1 TECHNICAL DATA 2 PACK CONTENTS 3 PRE INSTALLATION INFO 4 6 INSTALLATION 7 8 SETTINGS ADJUSTMENT WITH REMOTE CONTROL 9 BATTERY...

Page 3: ...ial If any parts are missing do not attempt to install your electronic faucet until you obtain the missing parts WARNINGS Do not install facing a mirror or any other electronic system operated by an infrared sensor To prevent reflection problems it is recommended to keep a minimum distance of 1 50 meters between the faucet and any other objects PREPARATION FOR INSTALLATION Flush water supply lines...

Page 4: ...t into place NUT WASHER GASKET O RING NUT WASHER GASKET O RING O RING INSTALLATION STEP 3 CONNECTING THE WATER SUPPLY 1 Connect the flexible pipe to the water supply For models with temperature control connect the red flexible pipe to the hot water supply and the blue flexible pipe to the cold water supply 1 INLET VERSION 2 INLETS VERSION 2 Your faucet was supplied with a 0 5 GPM aerator installed...

Page 5: ...following Shut off the water supply In order to adjust the sensor with the remote control hold the remote control straight in front of the sensor in a distance of about 6 8 15 20cm Choose the function you want to adjust by pressing once on one of the function buttons After pressing once on a specific function button a quick flashing of the LED at the front of the sensor will occur At this stage yo...

Page 6: ...covered for more than 90 seconds the water flow will shut automatically To resume regular operation any obstruction must be removed Press the SEC button Wait until a quick flashing of the LED of the sensor eye is perceived Then press to increase the security time and to reduce it 24 HOUR HYGIENE FLUSH This model includes a 24 hours hygiene flush which is disabled To activate the hygiene flush pres...

Page 7: ...ing or maintenance products or substances could damage the surface of the faucet For surface cleaning of faucet use ONLY soap and water then wipe dry with clean cloth or towel When cleaning bathroom tile the faucets should be protected from any splattering of harsh cleansers SOLENOID VALVE SERVICING The solenoid valve diaphragm requires periodical cleaning every six 6 months Remove the diaphragm f...

Page 8: ... range No water coming out of the faucet Increase the range 1 Range is too short 2 LED in the sensor does not flash once when user s hands are within the sensor s range Decrease the range 2 Range is too long The battery must be replaced 3 Battery is completely used up 4 Unit is in Security Mode Eliminate cause of reflection 5 Sensor is picking up reflections from the washbasin or another object Co...

Page 9: ...Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 3804 1 800 796 6667 04 2021 01500518 A ...