![Symmons DURO ACTIVESENSE S6360B Installation And Maintenance Manual Download Page 7](http://html1.mh-extra.com/html/symmons/duro-activesense-s6360b/duro-activesense-s6360b_installation-and-maintenance-manual_1419833007.webp)
10
11
MAINTENANCE
FILTER CLEANING INSTRUCTIONS
This faucet is provided with one stainless steel filter preventing foreign particles to enter the lines. It
is recommended to clean the filter every six (6) months. If the water flow has decreased, this can be
because the filter is clogged. The filter can be cleaned as follows:
1. Shut-off the water shut off valve (angle valve).
2. Disconnect the flexible pipe/s.
3. Remove the filter(s) and wash it/them under running water.
4. Reassemble the parts.
5. Make sure that there is no water leakage.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of
any prohibited cleaning or maintenance products or substances could damage the surface of the
faucet. For surface cleaning of faucet use ONLY soap and water, then wipe dry with clean cloth or
towel. When cleaning bathroom tile, the faucets should be protected from any splattering of harsh
cleansers.
SOLENOID VALVE SERVICING
The solenoid valve diaphragm requires periodical cleaning every six (6) months. Remove the
diaphragm from the solenoid valve and examine it for dirt. in case it is dirty or clogged, wash it under
running water and reassemble it.
Do not attempt to dismantle the solenoid valve if you are unfamiliar with electronic solenoid valves.
SPARE PARTS LIST
Seals and screws kit
SF280
Solenoid valve kit
SF253
Filter
SF263
Battery box (batteries excluded)
SF258
12V switching transformer
SD010
SD010
12V Switching Transformer
SF258
Battery box
SF280
Seals and Screws kit
SF253
Solenoid valve kit
SF263
Filter