![Symmetricom TimeSource 3600 Manual Download Page 116](http://html.mh-extra.com/html/symmetricom/timesource-3600/timesource-3600_manual_1419630116.webp)
116
TimeSource 3600
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
31
If not using the TOD output, skip to Step 32. Use the Edit Equipment command to
set the TOD output.
ED-EQPT::TS3600:<ctag>:::TOD=b;
b
= TOD format (b = Cisco or NTP4)
32
Use the Edit Equipment command to allow or inhibit alarm conditioning on the
outputs. Inhibiting the alarm conditioning forces the TimeSource 3600 to continue
to output valid timing signals while in major alarm. This may be useful when testing,
troubleshooting, or in installations where a TimeSource 3600 that is in major alarm
may produce better timing signals than other sources (for example, offices without
additional holdover clocks in a distribution shelf).
ED-EQPT::TS3600:<ctag>:::ALMCOND=b;
b
= alarm conditioning of the outputs (b = ALW or INH)
33
Use the Copy Memory command to copy the database from volatile to nonvolatile
memory within the TimeSource 3600.
CPY-MEM:[tid]:TS3600:<ctag>::WKG,,AUX:DATA;
Note:
Although the database is automatically copied to nonvolatile memory once
per hour, it is recommended that the Copy Memory command be executed each
time the database is changed.
Procedure G. Power Up (cont’d)
Step
Procedure
Summary of Contents for TimeSource 3600
Page 1: ...TimeSource 3600 GPS Primary Reference Source 097 72060 01 Issue 2 ...
Page 4: ...4 TimeSource 3600 This page intentionally left blank ...
Page 16: ...16 TimeSource 3600 This page intentionally left blank ...
Page 121: ...4 Chapter TL1 Reference This chapter provides information for using the TL1 language ...
Page 223: ...6 Chapter Specifications This chapter provides equipment specifications ...
Page 247: ...Index ...