336 TimeProvider 5000 User’s Guide
098-00028-000 Revision F – May, 2012
Chapter 4 Provisioning
Provisioning Expansion Shelf E1 / 1PPS+TOD Outputs
Provisioning Expansion Shelf E1 / 1PPS+TOD Outputs
The following actions are required to provision an expansion shelf:
Enable DTI for each expansion shelf
Provision output signals for each expansion shelf
Enable state(s) of output(s)
Provisioning DTI for an Expansion Shelf
1. Login at the Admin or Config-user level.
2. Type
set exp-if dti exp0 in1 enable
and press
Enter
.
3. Type
set exp-if dti exp0 in2 enable
and press
Enter
.
Provisioning E1 Output Signals for Expansion Shelf
The TP E30 expansion shelf supports three frame types for the E1 outputs:
freq2048khz, CCS and CAS. The following parameters can also be configured:
CRC
SSM
SSM-bit
State
See
for the hierarchy of commands to provision the expansion shelf E1
outputs.
The output generation behavior can be provisioned for fast-track, warm-up, free-run
and holdover conditions. See
for the hierarchy of commands to
provision expansion shelf E1 output generation behavior.