Appendix B Configuring the TimeProvider 5000 and 500
Example
TimeProvider 5000 and 500 Configuration Example
lists the actions to configure the TimeProvider 5000 and TimeProvider
500 and to verify that network communication between the TimeProvider 5000 and
TimeProvider 500 is enabled. In this example, the TimeProvider 500’s configuration
is for non-VLAN Ethernet interface if0.
Table B-1. TimeProvider 5000 and 500 Configuration
TimeProvider 5000
TimeProvider 500
Connect to Craft Port
Use serial cable to connect Craft port to serial port
of laptop computer.
Connect to Craft Port
Use serial cable to connect Craft port to serial
port of laptop computer.
Serial Communication
Establish serial communication with TP5000 using
terminal emulation:
All Programs>Accessories>Communication>
HyperTerminal
COM1 port: 8 data bits, 1 stop bit, no parity, 57,600
baud rate, no flow control
Serial Communication
Establish serial communication with TP500
using terminal emulation
All Programs>Accessories>Communication>
HyperTerminal
COM1 port: 8 data bits, 1 stop bit, no parity,
57,600 baud rate, no flow control
Log on to TimeProvider 5000
User: admin
Password: symmadmin**
Log on to TimeProvider 500
User: admin
Password: symmadmin**
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...