Chapter 5 Maintaining the TimeHub 5500
Replacing Fuses
Replacing the Fuse in the Management Card
To replace the fuse on the Management card, follow the procedure in this section.
shows the location of the fuse holder on the card.
Figure 5-12. Location of Fuse F1 on the Management Card and the Output Driver Card
1. Put on a properly grounded ESD wrist strap.
2. If applicable, remove the cable connected to the Management card.
3. Using a #2 Phillips-head or Pozidrive screwdriver, loosen the captive screws on
the front panel of the card.
4. Remove the card from the shelf.
5. Using a GMT fuse puller, remove the fuse from the fuse holder labeled F1.
6. Replace the fuse with a 1-A GMT fuse. Do not force the fuse when inserting it;
the fuse should easily snap-fit into the holder.
7. Insert the card into the shelf: ensure that the card aligns properly with its mating
backplane connector; push the card into place until it is fully seated into the
backplane connectors.
8. Verify that the Power LED is lit.
9. Press the Cutoff pushbutton several times.
10.Verify that any alarm conditions are cleared.
11.If applicable, re-connect the cable that was connected to the card.
12.If using a local communication connection, verify that the Local LED is lit. If you
are using a LAN connection, verify that the Link LED is lit.
Front Panel
Fuse