Chapter 6 Alarms and Events
RS-422 Output Module Alarms and Events
294
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
RS-422 Output Module Alarms and Events
lists the alarms and events for the RS-422 Output module, and includes
the typical response for each alarm or event, it’s event number, and a description or
a suggested corrective action. The SNMP MIB trap is listed in the Alarm/Event/Trap
Description column.
lists the default parameters for the RS-422 Output
module alarms.
Table 6-22. RS-422 Output Module Alarm and Event Messages
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action
000
Hdw Config, Fault
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services.
001
Configuration, Fault
Redundant configuration mismatch. Re-seat or replace module.
002
Clk-A, Lost
Clock module in slot A1 is in warm-up mode or has other problems.
003
Clk-B, Lost
Clock module in slot A12 is in warm-up mode or has other
problems.
004
Clk-C, Lost
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
005
Clk-D, Lost
Only in SDU. Loss of backup clock. Check cable.
006
Clk Selected, None
No clocks, no output.
007
VCXO, Lost
VCXO problems, re-seat or replace module.
008
PLL, Unlocked
No clocks or VCXO. Re-seat and check clocks.
009
PortFlt, Fault, 40000
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
129
Install, RS422 Output
Module
Module Installed.
130
Remove, RS422 Output
Module
Module Removed.
131
Enable, RS422 Output
Module, COML
Module Enabled.
132
Disable, RS422 Output
Module, COML
Module Disabled.
133
Restart, in 5 seconds, COML
User request for a module to reboot.
134
Cannot Enable, RS422
Output Module, COML
Cannot enable module due to configuration error.
203
Bypass, On, COML
User has changed the Bypass mode.