Chapter 2 TL1 Reference
Set 2048 kHz Output Parameters
116
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
Set 2048 kHz Output Parameters
This command sets the parameters for the specified 2048 kHz Output modules.
Syntax
SET-PRMTR-CLKOUT:[tid]:[aid]:ctag::[pstate],[mode],[level],[bypass],
[fltmode],[squelch];
Empty fields leave parameters unchanged.
Related Commands
Retrieve 2048 kHz Clock Output Parameters
Parameter
Format
Description
aid
SxAy[-z]
Sets the parameters for the specfied 2048 kHz Output
module [or port].
pstate
ON | OFF
Turns the specified module [or port] on or off.
mode
This parameter is ignored.
level
ACQ | LOCK
Outputs are turned on when the active Clock module is at
or above the specified state.
bypass
ON | OFF
Allows operation when Clock C is the active clock.
fltmode
OFF | ON |
AUTO
Turns outputs on or off when the output level exceeds the
2.1 V fault threshold.
squelch
0 | 1-16
Turns off the specified port if the reference clock PQL
exceeds the squelch threshold specified in this field. 0
disables the function.