12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 413
Signal Names and Definitions
SDU-2000 Expansion Interface
illustrates the SDU Interface and the Backup Clock Connector, located
on the rear panel of the SSU-2000.
outlines signal names, definitions,
and locations of the SDU Expansion interface and backup clock connectors.
Figure D-6.
SDU Interface and Backup Clock Connector Pinouts
LMIN-NO
Local Minor Alarm, Normally Open Contact
TB1-7
LMIN-COM
Local Minor Alarm, Common Contact
TB1-8
LMIN-NC
Local Minor Alarm, Normally Closed Contact
TB1-9
RCRT-NO
Remote Critical Alarm, Normally Open Contact
TB2-1
RCRT-COM
Remote Critical Alarm, Common Contact
TB2-2
RCRT-NC
Remote Critical Alarm, Normally Closed Contact
TB2-3
RMAJ-NO
Remote Major Alarm, Normally Open Contact
TB2-4
RMAJ-COM
Remote Major Alarm, Common Contact
TB2-5
RMAJ-NC
Remote Major Alarm, Normally Closed Contact
TB2-6
RMIN-NO
Remote Minor Alarm, Normally Open Contact
TB2-7
RMIN-COM
Remote Minor Alarm, Common Contact
TB2-8
RMIN-NC
Remote Minor Alarm, Normally Open Contact
TB2-9
Table D-4. Signal Names and Locations of Alarms (Continued)
Name
Description
Connector–Pin