12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 231
Hardware Configuration Guide
Configuring a Subtending SSU
Installing Software
The Subtending SSU requires the software listed in
To install the software you need to use either the SynCraft application or the
SSU-2000 Download application
Using the SynCraft Application
To use the SynCraft application to install software, refer to the on-line
documentation provided within the program.
Changing From Subtending SSU Mode
To change a Subtending SSU back to the normal mode:
1. Log in to the SSU-2000 and press the
Enter
key. The system prompt appears.
2. Type
opermode normal
and press the
Enter
key. The system responds with:
2002-08-15-T15:57:56Z ID: SSU2000 Name: SSU_2000
The SSU2000 is in Normal Mode
3. Type
bye
and press the
Enter
key to log off.
No hardware changes are necessary.
Table 9-2. Files Required for Upgrading the Firmware
Item Number to
be Upgraded
Description
File for Module
Firmware Upgrade
File for Module
PLD/FPGA Upgrade
23413012-000-0
23413012-001-0
23413012-002-0
23413012-003-0
Comms Module
01200D00.DN1
01201B00.DN1
01202B00.DN1
01203B00.DN1
SCOMFPGA.DN9
23413015-000-0
Stratum 3E Clock Module
01500C00.DN1
SCLKFPGA.DN9
23413016-000-0
Stratum 2 Clock Module
01500C00.DN1
SCLKFPGA.DN9
23413279-000-0
CC Input Module
27900A00.DN1
SSUCCINP.DN9
23413158-000-0
CC Output Module
15800B00.DN1
SSUCCOUT.DN9
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...