Output Module Reference Data
2048 kHz Output Module
194
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
As another example, if the hex number is A501F, then the following ports are
squelched: 1 and 3 (corresponding to the A in Digit 1), 6 and 8 (corresponding to the
5 in Digit 2), 16 (corresponding to the 1 in Digit 4), and 17 through 20
(corresponding to the F in Digit 5).
Use the Alarm command to display the alarm information for a given module to
display all 2048 kHz Output module alarms, including Alarm #14, Squelching. Use
the Alarm command to provision these alarms to be Ignored or to generate a Report
Only, Minor Alarm, Major Alarm (default), or a Critical Alarm. Refer to the
SSU-2000
User’s Guide
for more information on using the Alarm command.
Table 8-10. Identifying Failed Ports from the Hex Digit
Hex Value
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
Port
1
5
9
13
17
Port
2
6
10
14
18
Port
3
7
11
15
19
Port
4
8
12
16
20
0
–
–
–
–
1
–
–
–
X
2
–
–
X
–
3
–
–
X
X
4
–
X
–
–
5
–
X
–
X
6
–
X
X
–
7
–
X
X
X
8
X
–
–
–
9
X
–
–
X
A
X
–
X
–
B
X
–
X
X
C
X
X
–
–
D
X
X
–
X
E
X
X
X
–
F
X
X
X
X
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...