12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 187
Output Module Reference Data
E1/2048 kHz Output Module
lists the failed output port number(s) for each possible hex digit. In the
above alarm message, the hex number is 00001. To determine the port in alarm,
locate the second row (corresponding to Hex Value 1) in
. The right-most
column has an X, which corresponds to Port 20 (read across from Digit 5).
As another example, if the hex number is A501F, then the following ports are
squelched: 1 and 3 (corresponding to the A in Digit 1), 6 and 8 (corresponding to the
5 in Digit 2), 16 (corresponding to the 1 in Digit 4), and 17 through 20
(corresponding to the F in Digit 5).
Use the Alarm command to display the alarm information for a given module; the
display includes all E1/2048 kHz Output module alarms, including Alarm #10,
Squelching. Use the
or the SET-PRMTR- OUTE12048 command (described in
page 304) to provision these alarms to Ignore, Report Only, Minor Alarm, Major
Alarm (default), or a Critical Alarm.
Table 8-7. Identifying Failed Ports from the Hex Digit
Hex Value
Digit 1
Digit 2
Digit 3
Digit 4
Digit 5
Port
1
5
9
13
17
Port
2
6
10
14
18
Port
3
7
11
15
19
Port
4
8
12
16
20
0
–
–
–
–
1
–
–
–
X
2
–
–
X
–
3
–
–
X
X
4
–
X
–
–
5
–
X
–
X
6
–
X
X
–
7
–
X
X
X
8
X
–
–
–
9
X
–
–
X
A
X
–
X
–
B
X
–
X
X
C
X
X
–
–
D
X
X
–
X
E
X
X
X
–
F
X
X
X
X
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...