Input Module Reference Data
GPS Input Module
162
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
GPS Input Module
This section provides user-reference data for the GPS Input module (part number
23413019-000-0) that is used in the SSU-2000 main chassis to provide a timing
reference signal to phase and frequency lock the internal clocks and to produce
phase locked output signals.
Functional Overview
The module consists of a Micro-controller and firmware, SRAM for data storage,
FLASH (which contains the firmware), a GPS receiver (radio), and other support
circuitry. The primary function of these modules is to perform time-interval
measurements on Clock module A and Clock module B, using the 1PPS provided
by the radio. These measurements are used to adjust the frequency of the
oscillators on those modules.
In addition, this module supports the Network Time Protocol (NTP), which is a
function provided by the Communications module. Time-of-day from the Radio is
transferred to the Communications module for distribution to clients connected to
the same network. The Communications module’s internal 1PPS is synchronized to
the 1PPS from the Radio.
The GPS Input modules monitor and report the status and performance of the
module and the received radio signals. Each module type communicates with the
Communications module to receive user configuration commands and to report
status and performance back to the Clock modules for frequency control.
MTIE T10000 Limit 2
1110/2840/1110
0 to 100000
MTIE Limit 1 Alarm Mode
Minor
Ignore, Report, Minor, Major, or Critical
MTIE Limit 2 Alarm Mode
Major
Ignore, Report, Minor, Major, or Critical
Alarm Initial Severity
Minor (except LOS
and level 2 MTIE,
which are Major)
Ignore, Report, Minor, Major, or Critical
Alarm Initial Delay
0 seconds
0 to 86400 seconds
Alarm Elevation Time
86400 seconds
0 to 500000 seconds
Port Status
Disabled
Enabled/Disabled
Port Name
Any user selected string from 0 to 20 characters
Table 7-8. DS1 Input Module Configuration (Continued)
Configuration Setting
Factory Default
Range
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...