OPERATION
3.3.7 EXTERNAL FREQUENCY MEASUREMENT MENU SCREEN (MODELS
ET6000 and ET6010 only)
Subsequent pushing of the MENU keyboard switch will display the External Frequency
Measurement Menu Screen which is shown below and contains the following choices:
Column:
1 5 10 15 20 25 30 35 40
| | | | | | | | |
EXT FRQ:+0000E-14 / +0000E+00 SEC *
1>ENTER FRQ <2>ENABLE<3>DISABLE
Row 1
Row 2
A. OPERATION
This feature provides the capability of using the GPS TC/FG to measure the stability/drift
of an external signal.
Note:
Because J10 is a multipurpose input connector, when the External Frequency
measurement option is enabled, the Single Event Log and the 1PPS Input option
(Time Interval Measurement) are disabled.
External Frequency Measurement is operational in the AUTO, DYNAMIC, and
STATIONARY modes when “LOCKED” with the following qualification: If after
achieving “LOCKED” the unit loses satellites and the “TRACKING” and “LOCKED”
LEDs go out, this function will still be operational until satellites are reacquired. At that
point, it won’t be operational again until “LOCKED” has been achieved. This function is
always available in “FLYWHEEL” mode.
The external frequency measurement can be set-up/configured from either the front panel
keyboard and LCD display or remotely via the RS-232 I/O port.
Pushing keyboard switch “1” followed by a number (00000001 to 10000000) will input
the frequency that the user is going to measure.
Pushing keyboard switch “2” will ENABLE the external frequency measurement option.
Pushing keyboard switch three will disable it.
Once the correct input frequency has been entered and the option turned on (enabled) if
the unit is not locked, “NOTLK” will appear in place of the asterisk (*). If the external
frequency measurement option is enabled and the unit is tracking a satellite, an asterisk
will appear. If the option is disabled, nothing will appear in this area.
If the unit is locked, the measurement count (once per second) will start to increment.
The number is auto scaled, so it will count from 0000E+00 to 9999E+00. The next count
will go to 0100E+02, etc.
Symmetricom Inc
ET6xxx ExacTime GPS TC & FG (Rev C)
3-17
Summary of Contents for ET6000
Page 136: ...OPTION DESCRIPTIONS ASSEMBLY 55116 Symmetricom Inc ET6 ExacTime GPS TC FG Rev C C 15 ...
Page 141: ...APPENDIX C ASSEMBLY 100002 C 20 ET6xxx ExacTime GPS TC FG Rev C Symmetricom Inc ...
Page 156: ...OPTION DESCRIPTIONS ASSEMBLY 55128 Symmetricom Inc ET6xxx ExacTime GPS TC FG Rev C C 35 ...
Page 162: ...OPTION DESCRIPTIONS ASSEMBLY 55115 Symmetricom Inc ET6xxx ExacTime GPS TC FG Rev C C 41 ...
Page 176: ...OPTION DESCRIPTIONS ASSEMBLY 55143 Symmetricom Inc ET6xxx ExacTime GPS TC FG Rev C C 55 ...
Page 185: ...APPENDIX C ASSEMBLY 55155 ET6xxx ExacTime GPS TC FG Rev C Symmetricom Inc C 64 ...