14
6502B RF Distribution User Guide
15247-201 Rev. B
– April 2009
Specifications
Power
Power
Operating Voltage 100
– 120 / 180 - 240 VAC, ±10%, 50/60 Hz,, 0.1/0.05 A <10 W
DC Input (Optional)
22 to 56 VDC, 10 W
Fuse Type
Little fuse, slow blow, 2/10A, 250V, 5x20mm
Mechanical
Height
1.75” (1 U)
Width
19” (including rack mount ears)
Depth
12”
Environment
Operating Temperature
0 to 55°C
Relative Humidity
0 to 95%, non-condensing
Overvoltage
Category II
Pollution
Degree 2
Intended for INDOOR USE ONLY
Altitude
Up to 2000 M
Alarm Output
Summary alarm indicates failure of any output signal.
Each Output & Main
Red LED
Non-alarm Condition
Relay energized (fail safe) Form-C Contacts
Alarm O/P Disable
Optional rear panel switch
Connector
9 pin D-male
Controls and Indicators
POWER
Green LED indicates power is connected
ALARM
Red LED indicates a signal output failure
HI Z/50
Ω
Slide switch: Unterminated or 50
Ω
Terminated
ALARM OVERRIDE (Optional) Toggle switch: Alarm output enabled or disabled
INPUT FAULT
Red LED indicates fault with input signal
OUTPUT FAULT
Ten red LEDs indicate fault with output
See “Controls and Indicators” on page 11 for more information.
Note:
If the input signal level is less than 10 dBm, please specify
the Low Alarm Threshold version (-509).