3. Specifications
Environmental Requirements
Temperature:
n
Operating: -40º C to +80 º C base-plate Standard 8200
n
Storage: -55º C to +95º C
n
Sensitivity: <3.0E-10 over op. temp. range
Thermal shock (non-operating)
:
MIL-STD-202, Method 107, Test Condition A, 10 cycles -55° C to 85º C
Orientation sensitivity:
<5.0E
-11
for any orientation
Pressure sensitivity:
<1.0E
-13
/mbar
Altitude
n
Operating: Sea level to 40,000' (12,192 m)
n
Non-operating: Sea level to 80,000' (24,384 m)
Magnetic field sensitivity:
dc(<=2Gauss)
<= ±4.0E
-11
/Gauss
Relative humidity (operating):
0 to 95% RH per MIL-STD-810, Method 507.4
Salt fog:
MIL-STD-810, Method 509.4