background image

Integrator Series Zone Mix 760

Quick Start Guide

Summary of Contents for Zone Mix 760

Page 1: ...Integrator Series Zone Mix 760 Quick Start Guide...

Page 2: ...2 Quick Start Guide 6408 216th Street SW Mountlake Terrace WA 98043 USA T 1 425 778 7728 F 1 425 778 7727 www SymetrixAudio com Safety...

Page 3: ...at produce heat This apparatus shall be connected to a mains socket outlet with a protective earthing connection Do not defeat the safety purpose of the polarized or grounding type plug A polarized pl...

Page 4: ...only for use with the ARC series of remotes DO NOT plug the ARC connectors on Symetrix products into any RJ 45 connector labeled SYMLINK ETHERNET or COBRANET The ARC RJ 45 connectors on Symetrix produ...

Page 5: ...nts sports bars fitness clubs night clubs hotels retail locations and casinos all at a ground breaking price Featuring twelve inputs four microphone eight line level and six outputs the 760 hosts micr...

Page 6: ...tion should not be impeded by covering the ventilation openings with items such as newspapers tablecloths curtains etc Weight 8 15 lbs 3 70 kg Front Panel Item Description Comments Mic Line Inputs Fou...

Page 7: ...S 485 controller wired in parallel A to A B to B and GND to GND using shielded twisted pair cabling Port Settings 38 4 kbaud 8 data bits 1 stop bit no parity no flow control Ethernet RJ 45 jack Commun...

Page 8: ...to review the Network Configuration section for more information When the 760 has a physical network connection the amber link LED on the ETHERNET connector will be lit solid When there is network com...

Page 9: ...e 760 s output level Refer to the OUTPUT LEVEL SET within the LIMITER module found in the OUTPUT DSP section of the software Audio Media Inputs Using standard cables terminated with male RCA connector...

Page 10: ...Right Duc 1 o 1 2 3 4 5 6 7 8 9 10 11 12 Zone Mix Main Mix Program Select 2 1 of 3 Emergency Output Routing Levels Channel 3 Pre Fade Only Program Select 1 o 1 2 3 4 5 6 7 8 9 10 11 12 Zone Mix Main M...

Page 11: ...rogram Select 1 o 1 2 3 4 5 6 7 8 9 10 11 12 Zone Mix Main Mix SPL Input Source Select o 1 2 3 4 5 6 7 8 9 10 11 12 1 of 3 1 of 1 SPL Computer on Zones 1 3 only Sense 1 of 1 1 of 8 1 of 6 Main Mix 1 2...

Page 12: ...e Mute SpeakerManager Delay HPF LPF Inv Speaker Manager Delay HPF LPF Speaker Manager Delay HPF LPF Speaker Manager Delay HPF LPF Speaker Manager Delay HPF LPF Speaker Manager Delay HPF LPF Output Fad...

Page 13: ...ectors can appear on either side of a balanced connection NOTE In the case of an XLR connector the Female attaches to an output while the Male attaches to an input Unbalanced Connections The RCA conne...

Page 14: ...at the balanced input Unbalanced Connections Balanced out to unbalanced in When your output requires a balanced connector but you are sending signal to an unbalanced input the rules change Use a singl...

Page 15: ...t should also have automatically self assigned a similar private IP address in the range of 169 254 x x and if this is the case you should be able to connect to the 760 directly Even if the PC s defau...

Page 16: ...54 254 and a Subnet Mask of 255 255 0 0 Connecting to the 760 through a Firewall VPN We have successfully tested control of a 760 through a firewall and VPN but are unable to guarantee performance of...

Page 17: ...ise leave set to Obtain an IP address automatically if using DHCP 6 Press OK to save and Close to exit out of the Local Area Connection Properties Configuring your computer for a network connection Wi...

Page 18: ...ly if using DHCP Press OK to close 8 Repeat steps 6 and 7 for Internet Protocol Version 6 TCP IPv6 if on an IPv6 network Consult your IT staff if you are unsure 9 Press OK to save and Close to exit ou...

Page 19: ...on to the Connection Wizard to get connected to your 760 Launch the software You can launch the Zone Mix 760 software via either the Start Menu or the Desktop icon Once launched the Zone Mix 760 softw...

Page 20: ...elect the device you wish to connect to and click the Next button However there are a few more functions on this screen worth mentioning Properties The device Properties dialog allows you to give a de...

Page 21: ...he range of 169 254 x x with a Subnet Mask of 255 255 0 0 in order to communicate with the 760 in a direct connect mode However if your PC is using the default network settings it should also have aut...

Page 22: ...your Inputs by typing directly in the scribble strip below the faders These names correspond to the audio sources connected to the physical inputs 1 12 of the 760 You may reset the Input Labels to the...

Page 23: ...Wizard Click the Finish button to exit After completing the Hardware Connections connecting with the Connection Wizard and finishing this Label Wizard you are ready to Go Online and explore the Softwa...

Page 24: ...irmware IMPORTANT The 760 Firmware must be matched with the version of the Room Combine Application you are using The correct firmware for the Application is always distributed with the Application an...

Page 25: ...s using the optional ARC Wall Panel remote controls All program memory shall be non volatile and provide program security should power fail The device shall provide an on board real time clock to faci...

Page 26: ...Said software is specifically excluded from this warranty Limitation of Liability The total liability of Symetrix on any claim whether in contract tort including negligence or otherwise arising out of...

Page 27: ...27 Integrator Series Zone Mix 760...

Page 28: ...ity with regard to the performance or use of these products Under copyright laws no part of this brochure may be reproduced or transmitted in any form or by any means electronic or mechanical without...

Reviews: