Overview

The Control I/O is a 1 rack space AirTools Studio Matrix system accessory which allows the system to control and be controlled 

from various external devices. The Control I/O serves to expand and augment a system’s capabilities. Additionally, the Control 

I/O provides a MIDI gateway to the system allowing the use of low-cost generic MIDI controllers for control of almost any DSP 

parameter. The Control I/O also provides a generic ASCII command protocol which allows it to be used in a stand-alone fashion 

or integrated into other RS-485 compatible control systems such as those made by AMX or Crestron.

Front Panel

Item 

 

Description    

What It Does

POWER   

 

Red LED 

 

Indicates that the unit is powered on.

RS-485 COMM 

 

Yellow LED 

 

Indicates active RS-485 communications.

MIDI COMM 

 

Green LED 

 

Indicates active MIDI communications.

Rear Panel

Item 

 

Description    

What It Does

POWER INPUT 

 

4 pin XLR jack 

 

Accepts power from a Symetrix PS-5 switching power supply (15 VDC @ 1.33 A).

DEVICE CONFIG   

8 DIP switch block   

Configures the Control I/O’s device address (0-31). Addressing is done in a binary

 

 

 

 

 

 

fashion. (See 

Device Address Quick Reference

).

RS-485   

 

Euroblock 

 

Connects to the Primary Studio Matrix hardware device at ADDR #1 or 3rd party

 

 

 

 

 

 

RS-485 compatible controller.

MIDI I/O   

 

Female DB15 

 

Allows external MIDI control via a standard DB15 “joystick” to (2) DIN 5 MIDI IN

 

 

 

 

 

 

and MIDI OUT cables adapter. (Adapter not included).

REMOTE ARCs 

 

4 x RJ-45 

 

Distributes power and RS-485 data to one or more ARCs per port.

 

 

 

 

 

 

(See 

ARC Network Design

)

RELAY OUTPUTS   

Euroblocks 

 

4 x SPDT relays rated at 3A, 24VDC, resistive; 0.3A, 60VDC, resistive and can be

 

 

 

 

 

 

wired normally open or normally closed.

OPEN COLLECTOR OUTPUTS  Euroblocks 

 

8 x open collector outputs with paired common ground pins. OC outputs go low

 

 

 

 

 

 

(0V) when active, and are internally pulled high (5V) when inactive and can drive

 

 

 

 

 

 

external LED indicators directly.

ANALOG CONTROL INPUTS  Euroblocks 

 

8 x analog control inputs able to be used as 8 potentiometer inputs, 8 mechanical

 

 

 

 

 

 

rotary encoder inputs, or as 16 switch inputs (+5 VDC reference voltage supplied).

Control I/O connections to AirTools Studio Matrix system

The Control I/O connects to any Primary Studio Matrix hardware device at ADDR #1 (any Ring). This would be any Studio 

Matrix audio I/O device in the system with a device address of 1 in the Primary position. The Control I/O connects via the RS-

485 ports using shielded twisted pair cable wired in parallel.

Note:

 when a redundant pair is at address 1, the RS-485 bus should be wired in parallel to both the Primary and Secondary units.

Warning! 

DO NOT plug the RJ-45 connectors labeled “REMOTE ARCs” into any RJ-45 connector labeled “SYMLINK”, 

“HOMERLINK” or “ETHERNET”.

Overview, Front Panel, Rear Panel, System Connection

Control I/O

RS-485 COMM

POWER

MIDI COMM

Studio Matrix

SYSTEM STATUS

POWER INPUT

15-24VDC�

20W MAX

MANUFACTURED BY SYMETRIX, INC. MTLK TERR, WA
THIS UNIT CONTAINS NO USER SERVICEABLE PARTS 

FABRIQUÉ AUX E.-U. PAR SYMETRIX, INC. MTLK TERR, WA
PAS DES ELEMENTS SERVIABLE PAR UTILISATEUR

POWER INPUT

ASCII / 

AirT

ool

s

UPGRADE / RUN

RESER

VED

RS-485

ADDR

RS-485

RELAY OUTPUTS

OPEN COLLECTOR OUTPUTS

ANALOG CONTROL INPUTS - SWITCH / POT / ENCODER

REMOTE ARCs

4

MIDI I/O

3

2

1

C NC

4

NO C NCNO C NCNO C NCNO

DEVICE CONFIG

1 2 4 8 16

B

A

3

2

1

8

7

6

5

4

3

2

1

8 7

6 5

4 3

2 1

B A

B A

B A

B A

B A

B A

B A

B A

+5V

+5V

+5V

+5V

+5V

+5V

+5V

+5V

CONTROL I/O

Engineered By

www.airtoolsaudio.com

Summary of Contents for Airtools Control I/O

Page 1: ...es and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electri cian for replacement of the obsolete...

Page 2: ...See ARC Network Design RELAY OUTPUTS Euroblocks 4 x SPDT relays rated at 3A 24VDC resistive 0 3A 60VDC resistive and can be wired normally open or normally closed OPEN COLLECTOR OUTPUTS Euroblocks 8...

Page 3: ...oosing third party products which are compatible with Symetrix products rests solely with the qualified contractor consultant or system designer Open Collector Output Wiring The following illustration...

Page 4: ...eet that can help a system designer determine power requirements based upon cable length number of ARCs and the power supply to be used This spreadsheet can be downloaded from the SymNet Technical Sup...

Page 5: ...Studio Matrix DSP design Device Address Quick Reference Every RS 485 device including all ARCs and Control I Os connected to the same Studio Matrix Ring must be uniquely identified You may use the pi...

Page 6: ...Studio Matrix commands but instead to a simple ASCII based protocol suitable for AMX Crestron type controllers or even a simple terminal program Command Set The address field must match the value of...

Page 7: ...of the open collectors to be set This is useful for initializing the open collector outputs to a given state on powerup Command SO address output state cr Where output is a decimal number 1 8 and sta...

Page 8: ...a decimal number 1 4 and state is 0 for off and 1 or greater for on An off state of the relay corresponds to the NC of the relay connector being connected to the common C connection An on state corre...

Page 9: ...MIDI controller number 1 127 that has changed will be returned Each poll will return the lowest numbered changed controller until all the changed parameters have been reported Only MIDI channel 1 is...

Page 10: ......

Page 11: ...be liable for any incidental or consequential damages including but not limited to damage for loss of revenue cost of capital claims of customers for service interruptions or failure to supply and cos...

Reviews: