Symetrix 572 SPL User Manual Download Page 7

572

5

8.

If there are multiple loudspeaker zones, there probably ought to be a separate 572 for each
zone.

9.

If the power amplifier is larger than 300 watts (70-volt systems), 200 watts (8-ohm systems),
or 100 watts (4-ohm systems), then the internal 5-amp relay can’t handle the load current.
You must use an external relay.

10.

It is good to know the minimum and maximum ambient levels (dB SPL) that the system is
expected to handle. Of course, the sound system should be able to exceed the maximum
ambient by 3-6 dB (unless it’s in the design that the system can’t out-shout the crowd).

11.

It’s preferable that the 572 mix the paging signals with the background music or other
signals internally through its separate paging and music inputs (as opposed to supplying
the 572 with a mix of everything). The 572 monitors its paging inputs and immediately
terminates a sense period when a paging signal is present. This is not true for the music
input.

12.

Loudspeakers from “alien” systems (sound systems located within the sensing zone of the
572, but not under control of the 572) can cause unwanted gain changes.

Connections

A drawing of a typical music with paging system is shown in below. Make all of the following
connections:
1.

Paging microphone (or mic-level mixer output) to the P

AGE

 M

IC

 XLR connector. Remember

that mic or line paging sources duck the signal connected to the M

USIC

 input.

2.

Line-level paging source (or other source) to the P

AGE

 terminals on TB1. Remember that

mic or line paging sources duck the signal connected to the M

USIC

 input.

3.

Background or foreground music source to the M

USIC

 terminals on TB1. Signals connected

to this input are ducked (attenuated) by signals present on either of the P

AGE

 inputs.

4.

SPL Computer output from TB1 to your sound system’s amplifier(s).

5.

Your sound system’s amplifier output to the 572’s F

ROM

 A

MP

 terminals on TB2.

6.

The speaker output of the 572 to the sound system speakers in the controlled zone.

Figure 3-1.   572 generic hookup diagram.

Caution

Failure to connect the 572 to the proper ac mains voltage may cause fire and/
or internal damage. There are no user serviceable parts inside the chassis. Refer all
service to qualified service personnel or to the factory.

Warning

Lethal voltages are present inside the chassis. There are no user serviceable parts
inside the chassis. Refer all service to qualified service personnel or to the factory.

TO/FROM HOUSE

SPEAKER SYSTEM

SPEAKER USED FOR

P.A AND SENSE

SPEAKER USED

FOR P.A.

DOES NOT SENSE

HOUSE

AMPLIFIER

TELEPHONE

SYSTEM

BACKGROUND

MUSIC

PAGE

MICROPHONE

AC INPUT

18W MAXIMUM

POWER

MIC

PAGE

MUSIC

PAGE

LINE INPUTS

OUTPUT

LINE

SPARE

TRIG

SENSE

EXT

CNTRL

RELAY

EXT

AMP

FROM

SPEAKER

TO

1

2

3

4

5

6

7

8

9

0

1

1

B

T

1

2

3

4

5

6

7

8

9

0

1

2

B

T

Vc

THIS UNIT CONTAINS NO USER SERVICABLE PARTS.

FABRIQU AUX E.-U. PAR SYMETRIX INC., LYNNWOOD, WASHINGTON.

É

R F REZ TOUTE R PARATION

UN TECHNICIEN QUALIFI .

É É

É

É

À

UNITED STATES OF AMERICA

LYNNWOOD WASHINGTON,

MANUFACTURED IN

FUSE

PRESS

Summary of Contents for 572 SPL

Page 1: ...572 572 SPL Computer User s Guide...

Page 2: ...y means electronic or mechanical including photocopying scanning recording or by any information storage and retrieval system without permission in writing from Symetrix Inc 572 6408 216th St SW Mount...

Page 3: ...on and identifies errors You show the 572 the parameters of the acoustic environment during calibration and then set the way you want the unit to respond to changes The 572 then takes the information...

Page 4: ...kes one to two seconds Any signal applied to the paging inputs during this time immediately terminates the sense period If a silent period never occurs the 572 forces one A front panel control determi...

Page 5: ...power cord is essential for safe operation Grounding The chassis of this product is grounded through the grounding conductor of the power cord To avoid electric shock plug the power cord into a proper...

Page 6: ...by the 571 during the calibration procedure is used by the microprocessor to calculate gain changes As a result the unit doesn t care what the actual ambient noise level is during calibration However...

Page 7: ...2 Line level paging source or other source to the PAGE terminals on TB1 Remember that mic or line paging sources duck the signal connected to the MUSIC input 3 Background or foreground music source to...

Page 8: ...rs unity gain when the output is operated unbalanced and the gain is 6 dB when the output is operated balanced Calibration Procedure 1 Apply program or paging signals to the 572 s input s 2 Press the...

Page 9: ...OUTPUT Sets the ambient gain ratio from 2 1 to 1 2 This determines whether the 572 makes a smaller change than the ambient 2 1 or a larger change than the ambient 1 2 GAIN LEDdisplay LED bargraph tha...

Page 10: ...wering is not present If using a phantom powered microphone ensure that the phantom voltage does not exceed 15V Higher voltages may be used if the powering device contains blocking capacitors or isola...

Page 11: ...long as this terminal is grounded The terminal must remain grounded for at least one second in order to perform sensing SPARE TB2 1 Not used not connected GROUNDS TB1 10 6 3 Connect to circuit ground...

Page 12: ...hat the input signal causes a sample period the timer resets If the input material has sufficient silent periods the timer generated sample periods never occur In CAL mode the 572 acquires a history o...

Page 13: ...572 the RATIO control determines how much the output changes for a given change at the sense input In the 12 00 position the ratio is 1 1 a 1 dB sense change results in a 1 dB output change Turning th...

Page 14: ...does not predispose them to only this usage After all 1 4 inch jacks are sometimes used for loudspeakers which are anything but high impedance Therefore the presence of 3 pin XLR connectors should not...

Page 15: ...o the aforementioned impedances XLR Polarity Convention The 572 uses the international standard polarity convention of pin 2 hot The following chart shows the connections for each type of connector In...

Page 16: ...r source exter nally Note The microphone input is direct coupled there are no dc blocking capacitors If you use a phantom powered microphone the phantom supply voltage must be 15 volts or less 15 volt...

Page 17: ...en collector of a 2N4401 NPN transistor You must supply power for any external relay used The transistor s limits are VCEO 40V and Icmax 625 mA In when the BYPASS switch is pressed the line level MUSI...

Page 18: ...as many operational options mostly controlled by a 4 wide DIP switch located on the front panel The microprocessor scans the switches continuously any changes in their settings are acted upon almost i...

Page 19: ...g The system audio level will return to normal in 10 seconds It may be helpful to monitor the acoustical level in the space with a sound level meter 10 Calibration is complete The 572 will adjust the...

Page 20: ...DOWN Disabled OptionSwitchC SAMPLEAVERAGING UP Running Average DOWN No Average OptionSwitchD EXTERNALSENSE UP Enabled DOWN Disabled What Could Go Wrong Here are the two most common situations and som...

Page 21: ...f this isn t desirable then exclude that particular speaker from the speakers used for sensing by connect the offending speaker s directly to the amplifier output bypassing the 572 In other cases dire...

Page 22: ...the line transformers With highly efficient speakers this may present a problem because the sense input of the 572 may be overloaded Use OPTION switch B to check the level coming back Refer also to t...

Page 23: ...the RATIO control determines how much the output changes for a given change at the sense input In the 12 00 position the ratio is 1 1 a 1 dB sense change results in a 1 dB output change Turning the R...

Page 24: ...imum output level of the 572 regardless of the setting of the RATIO control or the ambient noise level The rule here is the change in ambient level times the slope may not exceed MAXL If the computed...

Page 25: ...espresso machines for sensing In bars and lounges keep any speakers mounted near the blenders and dishwashers behind the bar out of the sensing circuit Remember that any extraneous sound sources like...

Page 26: ...nd the line level paging input for facility wide paging Use the music input for background music if any RaceTracks Different race tracks have different noise sources In auto racing the cars usually ma...

Page 27: ...he PAGE MIC INPUT Unitdoesnotaccuratelyadjustsystemasambientnoisechanges Bad calibration Repeat procedure during quiet time Hum induced in speaker wiring Ensure that speaker wiring is not routed adjac...

Page 28: ...40 dB overall max range and shall be governed by a microprocessor which shall be controlled by embedded software The device shall vary its gain based upon measurements of the sound pressure level of...

Page 29: ...on and buyer s remedies hereunder are SOLELY and exclusively as stated herein This Symetrix product is designed and manufactured for use in professional and studio audio systems and is not intended fo...

Page 30: ...collect shipments Just do these five things and repairs made in warranty will cost you only one way freight charges We ll prepay the return surface freight If you choose to send us your product in so...

Page 31: ...lling the 572 when to sense electronic wizardry slavelabor etc OPTION switch D has one additional use forcing multiple 572s to sample simultaneously There are two reasons for doing this 1 Adjacent sou...

Page 32: ...M TO SPEAKER MUSIC LINE INPUTS Vc LINE PAGE SENSE TRIG EXT RELAY CNTRL EXT SPARE OUTPUT AMP FROM TO SPEAKER MUSIC LINE INPUTS Vc LINE PAGE SENSE TRIG EXT RELAY CNTRL EXT SPARE OUTPUT AMP FROM TO SPEAK...

Page 33: ...D OUT FEMALE XLR PIN 1 GROUND PIN 2 HIGH PIN 3 LOW MALE XLR PIN 1 GROUND PIN 2 HIGH PIN 3 LOW MALE TS PLUG TIP HIGH SLEEVE GROUND LOW MALE TRS PLUG TIP HIGH RING LOW SLEEVE GROUND MALE TRS PLUG TIP HI...

Page 34: ...572 32 Symetrix Inc 6408 216th St SW Mountlake Terrace WA 98043 USA Tel 425 778 7728 Fax 425 778 7727 Website http www symetrixaudio com Email symetrix symetrixaudio com...

Reviews: