background image

SYMEO Local Positioning Radar System 

STU 

Quick Start Guide 

  

Connections

 

Copyright © Symeo GmbH 2011 

 

 

Page 5 of 10 

3

 

Connections 

 

Power has to be connected to internal 3pin terminal connector. Ground has to be connected to the 
terminal 2 (terminal in the middle of the connector), positive DC supply can be connected to two 
outer terminals. The STU is fused, protected against overvoltage and against reverse polarity. 

 

Attention: The STU is only rated IP65 if prober connectors (e.g. Harting Push Pull RJ45 part number 
09451451100) are used and if all unused feed-through are properly sealed. 

Power connector: 

Positive supply e.g. 12VDC 

Common Ground e.g. GND 

Positive supply e.g. 12VDC 

 

Summary of Contents for STU

Page 1: ...SYMEO LOCAL POSITIONING RADAR Product Manual STU Symeo Telemetric Unit...

Page 2: ...e packaging for returns and whenever the system is to be transported This ensures protection from crushing impacts moisture and electrostatic discharge During setup and before operation refer to the i...

Page 3: ...ry measures Touch a grounded object or carry a ground strap before touching the contacts This will divert static charges Proper operation in accordance with IEC60950 EN60950 of the device is only assu...

Page 4: ...HP Auto MDIX Auto negotiation 1x Micro SDHC card 1x USB e g for USB storage devices Optional hardware 8 Digital inputs opto isolated 8 Digital outputs opto isolated 4 ADC inputs opto isolated UMTS HS...

Page 5: ...erminal in the middle of the connector positive DC supply can be connected to two outer terminals The STU is fused protected against overvoltage and against reverse polarity Attention The STU is only...

Page 6: ...the basic network configuration of the STU needs to be changed connect to the STU by any webbrowser default address is http 192 168 1 99 First the main web page will show up If you choose Settings in...

Page 7: ...SYMEO Local Positioning Radar System STU Quick Start Guide Copyright Symeo GmbH 2011 Page 7 of 10 Here you can change the basic network settings...

Page 8: ...m STU Quick Start Guide Copyright Symeo GmbH 2011 Page 8 of 10 After having edited any setting you need to execute Upload changes and after that you need to reboot the STU New settings will only take...

Page 9: ...ith Part 15 of the FCC Rules and with RSS 210 of Industry Canada Operation is subject to the following two conditions this device may not cause harmful interference and this device must accept any int...

Page 10: ...nications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be de...

Reviews: