4-13
Spectrum24 RF Terminal Setup
where:
The following message is displayed:
Press <ENTER> when remote is ready. ESC to abort...
3. Do NOT press <ENTER> yet. Set up the 6840 using the _L.BAT utility as directed
in the section
Running _L.BAT
1. Place the 6840 in a configuration cradle.
2. Power the terminal on.
3. At a DOS prompt on the 6840, type _L<ENTER> using the keystrokes listed below.
For the 46-key 6840:
<SHF><FUNC><G><L><ENTER>
4. The terminal boots and displays the message:
Symbol Technologies
NVM Loader 2.X-XX
Connecting to Host
5. Press <ENTER> on the host PC.
6. The batch file runs Program Loader with the communications parameters set to
38,400 bps, 7 data bits, odd parity, and no flow control. The 6840 displays the
screen:
Symbol Technologies
NVM Loader 2.09-XX
SENDHEX
is the command
<file name>
is the hex file for the application being loaded. There may be other
application hex files which load other software (e.g., STEP version 2.6.0 or
greater, or TelNet Clients 3.0 or greater) to the flash disk.
Note: Be sure to use applications that are flash-disk enabled.
38400
is the baud rate.
[1|2]
sets the host communications port the cradle is attached to.
Summary of Contents for Series 6800
Page 2: ...Series 6800 Product Reference Guide 70 32645 01 Revision A April 1998...
Page 9: ...viii Series 6800 Product Reference Guide...
Page 79: ...5 16 Series 68XX Product Reference Guide...
Page 89: ...6 10 Series 68XX Product Reference Guide...
Page 101: ...7 12 Series 68XX Product Reference Guide...
Page 105: ...B 2 Series 68XX Product Reference Guide...
Page 108: ...C 3 Specifications Scanning Decode Zones Standard...
Page 109: ...C 4 Series 68XX Product Reference Guide...