background image

2-114 

P 300STD/FZY/PRO Scanner Product Reference Guide

Convert All to Code 39

Note: This parameter is available only on the P 300FZY.

Select whether or not to convert the decoded output to Code 39.

Convert All to Code 39

Do Not Convert All to Code 39

Summary of Contents for P 300FZY

Page 1: ...P 300STD FZY PRO Scanner Product Reference Guide...

Page 2: ...2 72 39417 03 Revision A October 2000 Symbol Technologies Inc One Symbol Plaza Holtsville N Y 11742 P 300STD FZY PRO Scanner Product Reference Guide...

Page 3: ...P 300STD FZY PRO Scanner Product Reference Guide 72 39417 03 Revision A October 2000...

Page 4: ...rk from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereun...

Page 5: ...ure xiv General xv Chapter 1 Getting Started Introduction 1 1 Unpacking 1 1 Accessories 1 2 Cables 1 2 User Documentation 1 2 Optional Accessories 1 2 Setting Up the P 300 Scanner 1 2 Installing the C...

Page 6: ...pe 2 12 RS 232C Host Types 2 12 Beeper Volume 2 13 Beeper Tone 2 14 Laser On Time 2 15 Power Mode 2 16 Trigger Mode 2 17 Beep After Good Decode 2 18 Transmit No Read Message 2 19 Decode Buffering 2 19...

Page 7: ...2 47 Enable Disable ISBT 128 2 48 Lengths for Code 128 2 49 Enable Disable Code 39 2 50 Enable Disable Trioptic Code 39 2 51 Set Lengths for Code 39 2 52 Code 39 Check Digit Verification 2 54 Transmi...

Page 8: ...sion Speed 2 90 Aiming Mode 2 92 Transmit Code ID Character 2 93 Transmit Code ID Character 2 94 Pause Duration 2 95 Prefix Suffix Values 2 96 Scan Data Transmission Format 2 97 RS 232C Parameters 2 9...

Page 9: ...r 2 135 Abort Macro PDF Entry 2 135 Chapter 3 Advanced Data Formatting ADF Introduction 3 1 Rules Criteria Linked to Actions 3 1 Using ADF Bar Codes 3 2 ADF Bar Code Menu Example 3 3 Alternate Rule Se...

Page 10: ...pter 4 Maintenance and Troubleshooting Maintenance 4 1 Troubleshooting 4 2 Appendix A Programming Reference UCC EAN 128 A 1 AIM Code Identifiers A 3 Prefix Suffix Values A 6 Appendix B Keyboard Maps A...

Page 11: ...ns Chapter 2 Programming the Scanner contains all the bar codes necessary to program your P 300 scanner Chapter 3 Advanced Data Formatting ADF explains how to customize scanned data before transmissio...

Page 12: ...tial Sequential lists e g those that describe step by step procedures appear as numbered lists Related Publications P 300 STD FZY PRO Series Quick Reference Guide p n 72 39416 xx provides instructions...

Page 13: ...ing the units improperly can possibly void the warranty If the original shipping container was not kept contact Symbol to have another sent to you Symbol Support Centers For service information warran...

Page 14: ...5794 Outside Austria Denmark Symbol Technologies AS Gydevang 2 DK 3450 Allerod Denmark 7020 1718 Inside Denmark 45 7020 1718 Outside Denmark Europe Mid East Distributor Operations Contact your local...

Page 15: ...Lomas de Chapultepec CP 11000 Mexico City DF Mexico 5 520 1835 Inside Mexico 52 5 520 1835 Outside Mexico Netherlands Symbol Technologies Kerkplein 2 7051 CX Postbus 24 7050 AA Varsseveld Netherlands...

Page 16: ...nty Coverage and Procedure During the warranty period Symbol will repair or replace defective products returned to Symbol s manufacturing plant in the US For warranty service in North America call the...

Page 17: ...ility and fitness for a particular purpose The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages including without limitation special indirect or co...

Page 18: ...xvi P 300STD FZY PRO Scanner Product Reference Guide...

Page 19: ...Synapse P 300PRO performs one and two dimensional bar code scanning uses multi interfaces of RS 232 and Synapse P 300IMG performs point and shoot image capture outputs to digital formats of TIFF JPEG...

Page 20: ...lation Cable 25 39803 01 Synapse Cable 25 38700 01 User Documentation The following user documentation is provided with your scanner P 300 Scanner Quick Reference Guide p n 72 39416 xx P 300 Scanner S...

Page 21: ...twist to the right Note Do not pull the trigger while installing a cable on the scanner Connecting Power If your host does not provide power to the scanner you will need to connect external power to t...

Page 22: ...ction can be made either directly from the scanner to the host or indirectly through a Synapse adapter cable to the host RS 232 Direct Connection 1 Connect the interface cable to the bottom of the sca...

Page 23: ...f the power cable into the power receptacle on the interface cable and plug the other end into a wall outlet Keyboard Wedge Connection When configured for keyboard wedge input the host accepts input f...

Page 24: ...cable and plug the other end into a wall outlet Synapse Cable Connection Symbol s Synapse Smart Cables enable interfacing to a variety of hosts The Synapse cable has the built in intelligence to dete...

Page 25: ...ynapse 4 If needed plug one end of the power supply into the power receptacle on the RS 232 cable Plug the other end into a wall outlet 5 If needed plug one end of the power supply into the power rece...

Page 26: ...he Scanner for the specific bar code programming information P 300PRO Scanning Mode Options The P 300PRO supports several scanning options Smart Raster The P 300PRO programmable Smart Raster capabilit...

Page 27: ...with Smart Raster performance Slab Only Raster Scanner activation creates a slab raster pattern which does not open vertically regardless of bar code type This may provide optimal performance on small...

Page 28: ...option There are two programmable timeout periods for this option normal and extended Slab Raster Option A trigger pull creates the slab raster pattern If the target is a 1 D bar code the pattern nev...

Page 29: ...nner up to 65 forward or back and still achieve a successful decode Simple practice quickly shows what tolerances to work within Scanning PDF417 2D Bar Codes P300 PRO only PDF417 scanning is enabled b...

Page 30: ...e a few passes to decode the symbol The bar code has been completely decoded when you hear a tone followed by a short high tone beep The greed LED on the scanner lights The green LED stays lit for two...

Page 31: ...1 13 Getting Started PDF417 PDF417 Symbol Technologies Inc The Gettysburg Address...

Page 32: ...the scan pattern but no more than 7 away Make sure the scan pattern extends at 3 4 inch beyond the symbol s edges When the symbol is properly oriented the scan pattern expands vertically to cover the...

Page 33: ...his occurs if a unit is not properly configured Check option settings 5 Beeps low tone Convert or format error Low high low tone ADF transmit error High high high low tone RS 232 receive error Paramet...

Page 34: ...in data transmission Low high tone A successful transmission of buffered data Table 1 2 Macro PDF Beeper Indications Beeper Sequence Indication Error 1 Low Long Hi level decode error caused by incorr...

Page 35: ...ingle short Standard decode and transmit beep for all symbols Double short MPDF symbol is buffered A single beep indicates transmission of the buffered data Table 1 2 Macro PDF Beeper Indications Beep...

Page 36: ...1 18 P 300STD FZY PRO Scanner Product Reference Guide...

Page 37: ...ace the standard default values in memory and are preserved even when the scanner is powered down The default parameter values can be recalled by scanning the Set All Defaults bar code on page 2 9 Eve...

Page 38: ...s 2 16 Trigger Mode N A Level 2 17 Beep After Good Decode Enable Enable 2 18 Transmit No Read Message Disable Disable 2 19 Decode Buffering N A Enable 2 19 LRC Checksum Disable Disable 2 20 Linear Cod...

Page 39: ...ansmit UPC E Check Digit Enable Enable 2 35 UPC A Preamble System Character System Character 2 36 UPC E Preamble System Character System Character 2 37 UPC E1 Preamble System Character System Characte...

Page 40: ...nsmit Code 39 Check Digit Disable Disable 2 55 Code 39 Full ASCII Conversion Disable Disable 2 56 Buffer Code 39 Disable N A 2 57 Convert Code 39 to Code 32 Disable Disable 2 60 Code 32 Prefix Disable...

Page 41: ...able 2 77 NOTIS Editing Disable Disable 2 78 MSI Plessey MSI Plessey Disable Disable 2 79 Set Length s for MSI Plessey Any Length Any Length 2 81 MSI Plessey Check Digits One One 2 82 Transmit MSI Ple...

Page 42: ...ffix Values 7013 CR LF for serial Enter 2 96 Scan Data Transmission Format Data as is Data As Is 2 97 RS 232C RS 232 Host Type Standard Standard 2 12 Baud Rate 9600 9600 2 100 Parity None None 2 101 C...

Page 43: ...eters Host Type IBM PC AT N A 2 115 National Keyboard Type North American N A 2 116 Fast Transmit Enabled N A 2 118 Intercharacter Delay 0 N A 2 119 Convert Control Characters Disable N A 2 119 MacroP...

Page 44: ...ansmit Macro PDF User Selected Field Transmit File Name N A Disable 2 133 Transmit Block Count N A Disable 2 133 Transmit Time Stamp N A Disable 2 133 Transmit Sender N A Disable 2 133 Transmit Addres...

Page 45: ...2 9 Programming the Scanner Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 2 1 on page 2 2 Set All Defaults...

Page 46: ...rd ICL FUJITSU NIXDORF Mode A Mode B Transmit Code ID No Yes Yes Yes Data Transmission Format Data as is Data Suffix Data Suffix Data Suffix Suffix CR LF 7013 CR 1013 CR 1013 CR 1013 Baud Rate 9600 96...

Page 47: ...rs are not programmable do not enable the Transmit Code ID feature Table 2 3 Terminal Specific Code ID Characters ICL FUJITSU NIXDORF UPC A A A A UPC E E E C0 EAN 8 FF FF B EAN 13 F F A Code 39 C len...

Page 48: ...canner Product Reference Guide Host Type RS 232C Host Types To select an RS 232C host interface scan one of the following bar codes Standard RS 232C ICL RS 232C Nixdorf RS 232C Mode A Nixdorf RS 232C...

Page 49: ...2 13 Programming the Scanner Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Volume Medium Volume High Volume...

Page 50: ...Scanner Product Reference Guide Beeper Tone This parameter sets the decode beep frequency or tone low medium or high Note This parameter is used by the P300 FZY and PRO only Low Frequency Medium Freq...

Page 51: ...seconds To set a Laser On Time scan the bar code below Next scan two numeric bar codes beginning on page 2 120 that correspond to the desired time on Single digit numbers must have a leading zero For...

Page 52: ...etermines whether or not power remains on after a decode attempt When in low power mode the scanner enters low power consumption mode to preserve battery life after each decode attempt When in continu...

Page 53: ...l activates the laser and decode processing The laser remains on and decode processing continues until a successful decode the trigger is released or the Decode Attempt Duration is reached If Pulse is...

Page 54: ...this symbol if you want the scanner to beep after a good decode Beep After Good Decode Scan this symbol if you do not want the scanner to beep after a good decode The beeper still operates during par...

Page 55: ...f a symbol does not read nothing is sent to the host Enable No Read Disable No Read Decode Buffering This option permits the scanner to store decode data until the host device is ready to receive them...

Page 56: ...data is as follows STX DATA ETX LRC If DATA contains the special characters STX ETX and DLE a DLE character is used as an escape character and is added before each of those characters so that the rece...

Page 57: ...ecurity levels increase the scanner s aggressiveness decreases Select the security level appropriate for your bar code quality Linear Security Level 1 The following code types must be successfully rea...

Page 58: ...ully read twice before being transmitted The following codes must be read three times Linear Security Level 3 Linear Security Level 4 All code types must be successfully read three times before being...

Page 59: ...only valid when a Linear Code Type Security Level see page 2 21 is enabled When this parameter is enabled a bar code must be successfully scanned in both directions forward and reverse before being de...

Page 60: ...Autodiscriminate Response Time This parameter extends the length of time during which the scanner tries to detect which host it is connected to on power up Note When connected to an LS 5700 5800 scann...

Page 61: ...life in scan stand mode select the time the scanner remains active following a successful decode Selectable options include 30 seconds 1 minute 2 minutes 3 minutes To awaken the scanner in low power...

Page 62: ...used in scan stand mode to prevent the beeper from beeping when a different symbol appears in the scanner s field of view before the timeout period between decodes has expired This is programmable in...

Page 63: ...2 27 Programming the Scanner Timeout Between Decodes Continued 1 2 3 4 5 6 7 8 9 0 Cancel...

Page 64: ...8 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable UPC E UPC A To enable or disable UPC E or UPC A scan the appropriate bar code below Enable UPC E Disable UPC E Enable UPC A Disable UP...

Page 65: ...2 29 Programming the Scanner Enable Disable UPC E1 To enable or disable UPC E1 scan the appropriate bar code below Enable UPC E1 Disable UPC E1...

Page 66: ...P 300STD FZY PRO Scanner Product Reference Guide Enable Disable EAN 8 EAN 13 To enable or disable EAN 8 or EAN 13 scan the appropriate bar code below Enable EAN 8 Disable EAN 8 Enable EAN 13 Disable E...

Page 67: ...2 31 Programming the Scanner UPC Coupon Code To enable or disable UPC Coupon Code scan one of the following bar codes Enable UPC EAN Coupon Code Disable UPC EAN Coupon Code...

Page 68: ...2 32 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable Bookland EAN To enable or disable EAN Bookland scan the appropriate bar code below Enable Bookland EAN Disable Bookland EAN...

Page 69: ...ers is selected and the P 300 Series scanner is presented with a UPC EAN plus supplemental symbol the UPC EAN is decoded and the supplemental characters ignored An autodiscriminate option is also avai...

Page 70: ...ge is from two to twenty times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected Scan the bar code below to...

Page 71: ...PC E Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC A or UPC E check digit Transmit UPC A Check Digit Do Not Transmit UPC A Check Digit Transmit UPC E C...

Page 72: ...ymbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the...

Page 73: ...itted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characters are considered part of the symbol No Pre...

Page 74: ...ead in characters for UPC E1 symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The lead in characte...

Page 75: ...UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E TO UPC A allows you t...

Page 76: ...E1 decoded data to UPC A format before transmission After conversion data follows UPC A format and is affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E1 T...

Page 77: ...ramming the Scanner Transmit UPC E1 Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC E1 check digit Transmit UPC E1 Check Digit Do Not Transmit UPC E1 Che...

Page 78: ...curity necessary for your application UPC EAN Security Level 0 This default setting allows the scanner to operate in its most aggressive state while providing sufficient security in decoding in spec U...

Page 79: ...y Level 2 UPC EAN Security Level 3 If you have tried Security Level 2 and are still experiencing misdecodes select this security level Be advised selecting this option is an extreme measure against mi...

Page 80: ...RO Scanner Product Reference Guide EAN 8 Zero Extend This parameter adds five leading zeros to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Enable EAN 8 Zero Extend Disabl...

Page 81: ...this parameter gives you the option of labeling the extended symbol as either an EAN 13 bar code or an EAN 8 bar code This affects Transmit Code ID Character and DECODE_DATA message When EAN Zero Exte...

Page 82: ...2 46 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below Enable Code 128 Disable Code 128...

Page 83: ...ing the Scanner Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below See Appendix A Programming Reference for details on UCC EAN128 Enable UCC EAN 128 Disabl...

Page 84: ...2 48 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable ISBT 128 To enable or disable ISBT 128 scan the appropriate bar code below Enable ISBT 128 Disable ISBT 128...

Page 85: ...2 49 Programming the Scanner Lengths for Code 128 No length setting is required for Code 128 The default setting is Any Length...

Page 86: ...2 50 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below Enable Code 39 Disable Code 39...

Page 87: ...aracters To enable or disable Trioptic Code 39 scan the appropriate bar code below Enable Trioptic Code 39 Disable Trioptic Code 39 Note Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simul...

Page 88: ...taining a selected length For example if you select Code 39 One Discrete Length then scan 1 4 only Code 39 symbols containing 14 characters are decoded Numeric bar codes begin on page 2 120 If you mak...

Page 89: ...first scan Code 39 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 2 120 If you make an error or wish to chang...

Page 90: ...on When enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those Code 39 symbols which include a modulo 43 check digit are decoded whe...

Page 91: ...Programming the Scanner Transmit Code 39 Check Digit Scan this symbol if you want to transmit the check digit with the data Transmit Code 39 Check Digit Enable Do Not Transmit Code 39 Check Digit Dis...

Page 92: ...e visible characters Code 39 Full ASCII interprets the bar code special character preceding a Code 39 character and assigns an ASCII character value to the pair For example when Code 39 Full ASCII is...

Page 93: ...t Buffer Code 39 option is selected decoded Code 39 symbols without leading spaces are transmitted immediately Scan and Store affects Code 39 decodes only If you select scan and store we recommend tha...

Page 94: ...lear Transmission Buffer To clear the transmission buffer read a symbol which contains only a start character a dash minus and a stop character The scanner issues a short high low high beep to signal...

Page 95: ...a low high beep Overfilling Transmission Buffer If a decoded symbol results in an overflow of the transmission buffer The scanner indicates that the symbol has been rejected by issuing three long hig...

Page 96: ...uide Convert Code 39 to Code 32 Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 Note Code 39 must be enabled in order for this parameter to function Convert Code...

Page 97: ...e 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character A to all Code 32 bar codes Note Convert Code 39 to Code 32 must be enabled for this parameter to functi...

Page 98: ...2 62 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable Code 93 To enable or disable Code 93 scan the appropriate bar code below Enable Code 93 Disable Code 93...

Page 99: ...One Discrete Length then scan 1 4 only Code 93 symbols containing 14 characters are decoded Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection scan CANCEL on p...

Page 100: ...12 characters first scan Code 93 Length Within Range Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 2 120 If you make an error or...

Page 101: ...2 65 Programming the Scanner Enable Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below Enable Interleaved 2 of 5 Disable Interleaved 2 of 5...

Page 102: ...2 of 5 One Discrete Length then scan 1 4 the only I 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 2 120 If you make an error or wish to change your selectio...

Page 103: ...ange Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection scan CANCEL on pag...

Page 104: ...Check Digit Verification When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm either Uniform Symbology Specification USS or Optical Produ...

Page 105: ...ogramming the Scanner Transmit I 2 of 5 Check Digit Scan a symbol below to transmit the data with or without the check digit Transmit I 2 of 5 Check Digit Enable Do Not Transmit I 2 of 5 Check Digit D...

Page 106: ...character I 2 of 5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zer...

Page 107: ...2 71 Programming the Scanner Enable Disable Discrete 2 of 5 To enable or disable Discrete 2 of 5 scan the appropriate bar code below Enable Discrete 2 of 5 Disable Discrete 2 of 5...

Page 108: ...of 5 One Discrete Length then scan 1 4 the only D 2 of 5 symbols decoded are those containing 14 characters Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection...

Page 109: ...ange Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection scan CANCEL on pag...

Page 110: ...2 74 P 300STD FZY PRO Scanner Product Reference Guide Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below Enable Codabar Disable Codabar...

Page 111: ...2 Codabar One Discrete Length Two Discrete Lengths This option allows you to decode only those codes containing two selected lengths For example if you select Codabar Two Discrete Lengths then scan 0...

Page 112: ...2 76 P 300STD FZY PRO Scanner Product Reference Guide Any Length Scanning this option allows you to decode Codabar symbols containing any number of characters Codabar Any Length...

Page 113: ...d this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note Symbol length does not include start and stop...

Page 114: ...78 P 300STD FZY PRO Scanner Product Reference Guide NOTIS Editing When enabled this parameter strips the start and stop characters from decoded Codabar symbol Enable NOTIS Editing Disable NOTIS Editin...

Page 115: ...2 79 Programming the Scanner Enable Disable MSI Plessey To enable or disable MSI Plessey scan the appropriate bar code below Enable MSI Plessey Disable MSI Plessey...

Page 116: ...ne Discrete Length then scan 1 4 the only MSI Plessey symbols decoded are those containing 14 characters Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection sca...

Page 117: ...e Then scan 0 4 1 and 2 single digit numbers must always be preceded by a leading zero Numeric bar codes begin on page 2 120 If you make an error or wish to change your selection scan CANCEL on page 2...

Page 118: ...essey Check Digits These check digits at the end of the bar code verify the integrity of the data At least one check digit is always required Check digits are not automatically transmitted with the da...

Page 119: ...y Check Digit Scan a symbol below to transmit the data with or without the check digit Transmit MSI Plessey Check Digit Enable Scan this symbol if you want to transmit the data without the check digit...

Page 120: ...erence Guide MSI Plessey Check Digit Algorithm When two MSI Plessey check digits option is selected an additional verification is required to ensure integrity Either of the two following algorithms ma...

Page 121: ...2 85 Programming the Scanner Enable Disable PDF417 Scan a bar code below to enable or disable PDF417 scanning Note This parameter is available only on the P 300PRO Enable PDF417 Disable PDF417...

Page 122: ...PRO Scanner Product Reference Guide Enable Disable MicroPDF Scan a bar code below to enable or disable MicroPDF417 scanning Note This parameter is available only on the P 300PRO Enable MICROPDF417 Di...

Page 123: ...DF417 symbols are transmitted with the one of the following prefixes C1 if the first codeword is 903 907 912 914 915 C2 if the first codeword is 908 or 909 C0 if the first codeword is 910 or 911 If di...

Page 124: ...2 914 or 915 is present If Ignore Linked Symbol is selected MicroPDF417 symbols beginning with codeword 906 907 912 914 or 915 are ignored If Autodiscriminate Linked Symbol is selected the scanner loo...

Page 125: ...wing scanning mode options see P 300PRO Scanning Mode Options on page 1 8 for descriptions Smart Raster Always Raster Slab Only Raster Programmable Raster Select a scanning mode Note This parameter is...

Page 126: ...er or Always Raster is enabled This parameter is intended for very specific applications and is usually not necessary Select the laser pattern s height and or rate of expansion 1 Scan the bar code for...

Page 127: ...2 91 Programming the Scanner Programmable Raster Height And Raster Expansion Speed Continued 1 2 3 4 5 6 7 8 9 0 Cancel...

Page 128: ...the P 300PRO This parameter allows you to select either an aiming dot or slab raster for aiming See Aiming Modes on page 1 10 for descriptions Select the aiming mode Note Aiming modes can not be used...

Page 129: ...aracter is inserted between the prefix and the decoded symbol The user may select no code ID character a Symbol Code ID character or an AIM Code ID character The Symbol Code ID characters are listed b...

Page 130: ...2 94 P 300STD FZY PRO Scanner Product Reference Guide Transmit Code ID Character Symbol Code ID Character AIM Code ID Character None...

Page 131: ...canning a two digit number i e two bar codes and are measured in 0 1 second intervals For example scanning bar codes 0 and 1 inserts a 0 1 second pause 0 and 5 gives you a 0 5 second delay Numeric bar...

Page 132: ...t by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 2 AIM Code Identifiers in Appendix A Programming Reference for conversion informati...

Page 133: ...ansmission Format scan the SCAN OPTIONS bar code below Then select one of four options When you have made your selection scan the ENTER bar code on the next page If you make a mistake scan the DATA FO...

Page 134: ...2 98 P 300STD FZY PRO Scanner Product Reference Guide Prefix Data Suffix Enter Data Format Cancel...

Page 135: ...the number of bits of data transmitted per second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it in dis...

Page 136: ...d character Select the parity type according to host device requirements If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure than an odd number of 1 bits are contained i...

Page 137: ...ways 1 Mark Select SPACE parity and the parity bit is always 0 Space If no parity is required select NONE None Check Parity Select whether or not the parity framing and overrun of received characters...

Page 138: ...ata is lost When the CTS line is negated the controller asserts the RTS line and waits up to 2 seconds for the host to assert CTS When the host asserts CTS data is transmitted If after 2 seconds defau...

Page 139: ...S CTS Hardware Handshaking Standard RTS CTS When RTS CTS Option 1 is selected the scanner asserts RTS before transmitting and ignores the state of CTS The scanner deasserts RTS when the transmission i...

Page 140: ...s RTS when transmission is complete RTS CTS Option 3 Software Handshaking This parameter offers control of the data transmission process in addition to or instead of that offered by hardware handshaki...

Page 141: ...cards the data There are no retries when a time out occurs ACK NAK ENQ When this option is selected the scanner waits for an ENQ character from the host before transmitting data If an ENQ is not recei...

Page 142: ...ata message The scanner waits indefinitely for the XON XON XOFF Host Serial Response Time out This parameter specifies how long the scanner waits for an ACK NAK or CTS before determining that a transm...

Page 143: ...rks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the re...

Page 144: ...requiring a 7 bit or 8 bit ASCII protocol 7 Bit 8 Bit Beep on BEL When this parameter is enabled the scanner issues a beep when a BEL character is detected on the RS 232C serial line BEL alerts the us...

Page 145: ...system time to service its receiver and perform other tasks between characters The delay period can range from no delay to 99 msec in 1 msec increments After scanning the bar code below scan two bar c...

Page 146: ...t Reference Guide Wand Parameters Wand Host Interface Note This parameter is available only on the P 300FZY Select the appropriate host by scanning one of the bar codes below Symbollink Controller Sym...

Page 147: ...2 111 Programming the Scanner Wand Emulator Bar Output Note This parameter is available only on the P 300FZY Select the option that matches your host system Bar High Bar Low...

Page 148: ...00STD FZY PRO Scanner Product Reference Guide Variable Leading Margin Note This parameter is available only on the P 300FZY Select a variable leading margin 80 msec 90 msec 100 msec 110 msec 120 msec...

Page 149: ...2 113 Programming the Scanner Variable Leading Margin cont d 150 msec 160 msec 170 msec 180 msec 190 msec 200 msec 140 msec...

Page 150: ...canner Product Reference Guide Convert All to Code 39 Note This parameter is available only on the P 300FZY Select whether or not to convert the decoded output to Code 39 Convert All to Code 39 Do Not...

Page 151: ...nner Keyboard Wedge Parameters Host Interfaces Note This parameter is available only on the P 300FZY Use these bar codes to select your host interface IBM PC AT IBM PS 2 50 55SX 60 70 80 Default IBM P...

Page 152: ...Product Reference Guide National Keyboard Types Note This parameter is available only on the P 300FZY Use these bar codes to select the appropriate national keyboard type North American French German...

Page 153: ...2 117 Programming the Scanner Italian Swedish British...

Page 154: ...meter is available only on the P 300FZY Older systems may require a slower transmission method If your system still needs additional time to process keyboard data after setting an Intercharacter Delay...

Page 155: ...ments After scanning the bar code below scan two bar codes beginning on page 2 120 to set the desired time out If you make an error or wish to change your selection scan CANCEL on page 2 122 Interchar...

Page 156: ...2 120 P 300STD FZY PRO Scanner Product Reference Guide Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3 4...

Page 157: ...2 121 Programming the Scanner 5 6 7 8 9...

Page 158: ...2 122 P 300STD FZY PRO Scanner Product Reference Guide Cancel If you make an error or wish to change your selection scan the bar code below Cancel...

Page 159: ...they encode the same data When scanning Macro PDF se quences scan the entire Macro PDF sequence without interruption If you scan a mixed sequence you get two long low beeps Lo Lo for inconsistent file...

Page 160: ...acro PDF417 symbol as decoded whether it is in sequential order or not Up to 1024 Macro PDF bar codes may be transmitted Scan in Sequence Only Transmit in Sequence Without Buffering This causes transm...

Page 161: ...nsmit Decode Mode Symbols Continued Buffer All Symbols Transmit When Complete Default Buffer Scans Out Of Order Transmit Scans In Order Transmit Any Symbol In Set No Particular Order Scan In Sequence...

Page 162: ...s output format is based on the AIM USA Uniform Symbology Specification for PDF417 1994 All output codewords take up exactly 4 characters for GLIs and 6 characters for ECIs However there may be non de...

Page 163: ...127 Programming the Scanner Transmit Symbols in Codeword Format Continued Enable or disable by scanning the appropriate bar code Enable Transmit In Codeword Format Disable Transmit In Codeword Format...

Page 164: ...s that can process transmissions containing special data sequences Scan a bar code below to either format special data e g GLI escapes MacroPDF417 Control Block optional fields according to the GLI Gl...

Page 165: ...ansmission In many receiving systems Character Set ECIs can be removed without affecting the way data is displayed or processed When deletion is selected the scanner transmits data from PDF417 and Mic...

Page 166: ...ect on symbols that were not encoded using ECIs This version of the product supports ECIs 000900 through 000913 used for efficient encoding of Common Data Syntax Format 00 99 If this parameter is disa...

Page 167: ...e output codeword format for transmitting any non GLI or non macro PDF codeword If this is not enabled and an unknown codeword is found a decode error beep sounds Enable or disable by scanning the app...

Page 168: ...Stamp This activates transmission of the time stamp field The field character tag is 923 002 For example the field may be 923 0022123443243234 Transmit Sender Activates transmission of the sender fiel...

Page 169: ...tinued Enable or disable by scanning the appropriate bar code Enable File Name Transmit Disable File Name Transmit Enable Block Count Transmit Disable Block Count Transmit Enable Time Stamp Transmit D...

Page 170: ...tinued Disable File Size Transmit Enable File Size Transmit Enable Checksum Transmit Disable Checksum Transmit Enable Macro PDF Control Header Transmit Disable Macro PDF Control Header Transmit Enable...

Page 171: ...ded Macro PDF data stored to that point transmits it to the host device and aborts from Macro PDF mode Abort Macro PDF Entry This clears all currently stored Macro PDF data in the buffer without trans...

Page 172: ...2 136 P 300STD FZY PRO Scanner Product Reference Guide...

Page 173: ...rm specific actions when the data meets certain criteria One rule may consist of single or multiple actions applied to single or multiple criteria For instance a data formatting rule could be the foll...

Page 174: ...These options are described in Criteria on page 3 14 3 Actions Scan all actions related to or affecting these criteria The actions of a rule specify how to format the data for transmission These optio...

Page 175: ...anufacturer ID P Part Number D Destination Code The distribution center uses a PC with dedicated control characters for manufacturer ID CTRL M part number CTRL P and destination code CTRL D At this ce...

Page 176: ...On Page Beep Indication 1 Begin New Rule 3 11 High High 2 Code 128 3 14 High High 3 Send next 5 characters 3 26 High High 4 Send CTRL M 3 51 High High 5 Send next 5 characters 3 26 High High 6 Send C...

Page 177: ...ere is a sale you may want to send only the following 24 class key 56712437 stock key and the cashier keys the price manually To implement this first enter an ADF rule that applies in the normal situa...

Page 178: ...ule sets within the rules you can disable them by scanning the appropriate bar codes in Disable Rule Set on page 3 13 Rules Hierarchy in Bar Codes The order of programming individual rules is importan...

Page 179: ...programming in the parameter Scan Data Transmission Format These rules reside in the same rule list as ADF Rules so the order of their creation is also important Default Rules Every unit has a defaul...

Page 180: ...ode exited High Low Low All criteria or actions were cleared for rule currently being entered continue entry of rule Low Last saved rule was successfully deleted The rule presently being entered is le...

Page 181: ...pes to be affected by rule 3 14 Code Lengths Defines the number of characters each code type must contain 3 17 Message Containing A Specific Data String Select whether formatting affects data that beg...

Page 182: ...38 3 43 Beeps Selects beep sequence for each rule 3 48 Send Keystroke Control Characters Keyboard Characters Send ALT Characters Send Command Characters Send Special Characters Send Keypad Characters...

Page 183: ...commands are provided on the next few pages Begin New Rule Save Rule Erase Quit Entering Rules Disable Rule Set Begin New Rule Scan this bar code to start entering a new data formatting rule Save Rule...

Page 184: ...e bar codes to erase criteria actions or rules Quit Entering Rules Scan this bar code to quit entering rules FN3 6C Erase Criteria And Start Again FN3 6A Erase Actions And Start Again FN3 81 Erase Pre...

Page 185: ...d Data Formatting ADF Disable Rule Set Use these bar codes to disable rule sets FN3 01 Disable Rule Set 1 FN3 02 Disable Rule Set 2 FN3 04 Disable Rule Set 4 FN3 03 Disable Rule Set 3 FN3 00 Disable A...

Page 186: ...f code types to be affected All selected codes must be scanned in succession prior to selecting other criteria If you don t select a code type all code types are affected FN3 6C13D01 Code 39 FN3 6C13D...

Page 187: ...3 15 Advanced Data Formatting ADF Code Types continued FN3 6C13D08 UPC A FN3 6C13D09 UPC E FN3 6C13D0A EAN 8 FN3 6C13D0B EAN 13 FN3 6C13D10 UPC E1 FN3 6C13D0F EAN 128...

Page 188: ...duct Reference Guide Code Types continued FN3 6C13D00 PDF417 FN3 6C13D1A ADF for Macro PDF417 Applies rule to each block in MPDF set FN3 6C13D05 IATA 2 Of 5 FN3 6C13D0E MSI Plessey FN3 6C13D11 Booklan...

Page 189: ...ode type must contain Select one length per rule only If you don t select a code length selected code types of any length are affected Note These codes are used to set the code length only this is not...

Page 190: ...3 18 P 300 STD FZY PRO Scanner Product Reference Guide Code Lengths continued FN3 6C13709 9 FN3 6C1370A 10 FN3 6C1370C 12 FN3 6C1370B 11 FN3 6C13707 7 FN3 6C13708 8...

Page 191: ...3 19 Advanced Data Formatting ADF Code Lengths continued FN3 6C1370D 13 FN3 6C1370F 15 FN3 6C13710 16 FN3 6C1370E 14 FN3 6C13711 17 FN3 6C13712 18...

Page 192: ...3 20 P 300 STD FZY PRO Scanner Product Reference Guide Code Lengths continued FN3 6C13714 20 FN3 6C13713 19 FN3 6C13715 21 FN3 6C13717 23 FN3 6C13718 24 FN3 6C13716 22...

Page 193: ...3 21 Advanced Data Formatting ADF Code Lengths continued FN3 6C13719 25 FN3 6C1371A 26 FN3 6C1371C 28 FN3 6C1371B 27 FN3 6C1371D 29 FN3 6C1371E 30...

Page 194: ...eric Keyboard beginning on page 3 84 3 Scan End Of Message on page 3 93 Specific String Any Location To apply formatting to data that contains a specific character or data string 1 Scan the bar code b...

Page 195: ...Formatting ADF Numeric Keypad Bar codes on this page should not be confused with those on the alphanumeric keyboard FN3 A0 0 FN3 A1 1 FN3 A3 3 FN3 A2 2 FN3 A4 4 FN3 A5 5 FN3 A7 7 FN3 A9 9 FN3 A6 6 FN3...

Page 196: ...oduct Reference Guide Rule Belongs To Set Scan a bar code below to select which set a rule belongs to FN3 6C12A3 Rule Belongs To Set 3 FN3 6C12A1 Rule Belongs To Set 1 FN3 6C12A2 Rule Belongs To Set 2...

Page 197: ...ns send all data up to a specific character selected from the Alphanumeric Keyboard on page 3 84 or send the next N characters N any number from 1 to 254 selected from the Alphanumeric Keyboard on pag...

Page 198: ...41007 Send Next 7 Characters FN3 6A141006 Send Next 6 Characters FN3 6A141008 Send Next 8 Characters FN3 6A141009 Send Next 9 Characters FN3 6A14100B Send Next 11 Characters FN3 6A14100A Send Next 10...

Page 199: ...Data continued FN3 6A14100C Send Next 12 Characters FN3 6A14100D Send Next 13 Characters FN3 6A14100F Send Next 15 Characters FN3 6A14100E Send Next 14 Characters FN3 6A141010 Send Next 16 Characters...

Page 200: ...Send Next 19 Characters FN3 6A141012 Send Next 18 Characters FN3 6A141014 Send Next 20 Characters FN3 6A141032 Send Next 50 Characters FN3 6A141064 Send Next 100 Characters FN3 6A141096 Send Next 150...

Page 201: ...d Move Cursor To a Character Scan the Move Cursor To Character bar code then any printable ASCII character from the Alphanumeric Keyboard on page 3 84 This moves the cursor to the position after the m...

Page 202: ...ect a character from the Alphanumeric Keyboard on page 3 84 If the character is not there the cursor does not move i e has no effect Skip Ahead N Characters Scan one of these bar codes to select the n...

Page 203: ...Ahead continued FN3 6A143305 Skip Ahead 5 Characters FN3 6A143306 Skip Ahead 6 Characters FN3 6A143308 Skip Ahead 8 Characters FN3 6A143307 Skip Ahead 7 Characters FN3 6A143309 Skip Ahead 9 Characters...

Page 204: ...uct Reference Guide Skip Ahead continued FN3 6A143332 Skip Ahead 50 Characters FN3 6A143396 Skip Ahead 150 Characters FN3 6A143364 Skip Ahead 100 Characters FN3 6A1433C8 Skip Ahead 200 Characters FN3...

Page 205: ...aracters Scan one of these bar codes to select the number of positions back you wish to move the cursor FN3 6A143401 Skip Back 1 Characters FN3 6A143403 Skip Back 3 Characters FN3 6A143402 Skip Back 2...

Page 206: ...nce Guide Skip Back continued FN3 6A143406 Skip Back 6 Characters FN3 6A143405 Skip Back 5 Characters FN3 6A143407 Skip Back 7 Character FN3 6A143408 Skip Back 8 Characters FN3 6A143409 Skip Back 9 Ch...

Page 207: ...rmatting ADF Skip Back continued FN3 6A143432 Skip Back 50 Characters FN3 6A143496 Skip Back 150 Characters FN3 6A143464 Skip Back 100 Characters FN3 6A1434C8 Skip Back 200 Characters FN3 6A1434FA Ski...

Page 208: ...g send next 5 characters three zeros are added to the first send and the next send is unaffected by the padding These options do not apply to the Send Keystroke or Send Preset Value options Remove All...

Page 209: ...bar code to disable space removal Remove Leading Zeros Scan this bar code to remove all leading zeros Stop Zero Removal Scan this bar code to disable the removal of zeros FN3 6A1262 Stop Space Remova...

Page 210: ...bar code containing the desired number of spaces This parameter is activated by Send commands FN3 6A146301 Pad Spaces To Length 1 FN3 6A146302 Pad Spaces To Length 2 FN3 6A146304 Pad Spaces To Length...

Page 211: ...with Spaces continued FN3 6A146308 Pad Spaces To Length 8 FN3 6A146307 Pad Spaces To Length 7 FN3 6A146309 Pad Spaces To Length 9 FN3 6A14630A Pad Spaces To Length 10 FN3 6A14630C Pad Spaces To Lengt...

Page 212: ...Pad Data with Spaces continued FN3 6A14630D Pad Spaces To Length 13 FN3 6A14630E Pad Spaces To Length 14 FN3 6A146310 Pad Spaces To Length 16 FN3 6A14630F Pad Spaces To Length 15 FN3 6A146311 Pad Spa...

Page 213: ...with Spaces continued FN3 6A146314 Pad Spaces To Length 20 FN3 6A146313 Pad Spaces To Length 19 FN3 6A146315 Pad Spaces To Length 21 FN3 6A146316 Pad Spaces To Length 22 FN3 6A146318 Pad Spaces To Len...

Page 214: ...Spaces continued FN3 6A146319 Pad Spaces To Length 25 FN3 6A14631A Pad Spaces To Length 26 FN3 6A14631C Pad Spaces To Length 28 FN3 6A14631B Pad Spaces To Length 27 FN3 6A14631D Pad Spaces To Length...

Page 215: ...ed number of zeros This parameter is activated by Send commands Use these bar codes to pad data with zeros FN3 6A146601 Pad Zeros To Length 1 FN3 6A146602 Pad Zeros To Length 2 FN3 6A146604 Pad Zeros...

Page 216: ...Guide Pad Data With Zeros continued FN3 6A146609 Pad Zeros To Length 9 FN3 6A14660A Pad Zeros To Length 10 FN3 6A14660C Pad Zeros To Length 12 FN3 6A14660B Pad Zeros To Length 11 FN3 6A146608 Pad Zero...

Page 217: ...ta With Zeros continued FN3 6A14660D Pad Zeros To Length 13 FN3 6A14660E Pad Zeros To Length 14 FN3 6A14660F Pad Zeros To Length 15 FN3 6A146610 Pad Zeros To Length 16 FN3 6A146611 Pad Zeros To Length...

Page 218: ...uide Pad Data With Zeros continued FN3 6A146613 Pad Zeros To Length 19 FN3 6A146614 Pad Zeros To Length 20 FN3 6A146615 Pad Zeros To Length 21 FN3 6A146617 Pad Zeros To Length 23 FN3 6A146616 Pad Zero...

Page 219: ...continued FN3 6A146619 Pad Zeros To Length 25 FN3 6A14661B Pad Zeros To Length 27 FN3 6A14661A Pad Zeros To Length 26 FN3 6A14661C Pad Zeros To Length 28 FN3 6A14661D Pad Zeros To Length 29 FN3 6A1466...

Page 220: ...3 48 P 300 STD FZY PRO Scanner Product Reference Guide Beeps Select a beep sequence for each ADF rule FN3 6A13A01 Beep Once FN3 6A13A02 Beep Twice FN3 6A13A03 Beep Three Times...

Page 221: ...an the Send __ bar code for the keystroke you wish to send Control Characters Scan these bar codes to send control characters FN3 6A144100 Send Control 2 FN3 6A144101 Send Control A FN3 6A144103 Send...

Page 222: ...nner Product Reference Guide Control Characters continued FN3 6A144108 Send Control H FN3 6A144109 Send Control I FN3 6A14410B Send Control K FN3 6A14410A Send Control J FN3 6A144107 Send Control G FN...

Page 223: ...ata Formatting ADF Control Characters continued FN3 6A14410C Send Control L FN3 6A14410D Send Control M FN3 6A14410F Send Control O FN3 6A14410E Send Control N FN3 6A144110 Send Control P FN3 6A144111...

Page 224: ...eference Guide Control Characters continued FN3 6A144113 Send Control S FN3 6A144112 Send Control R FN3 6A144114 Send Control T FN3 6A144115 Send Control U FN3 6A144117 Send Control W FN3 6A144116 Sen...

Page 225: ...ting ADF Control Characters continued FN3 6A144119 Send Control Y FN3 6A14411B Send Control FN3 6A14411A Send Control Z FN3 6A14411C Send Control FN3 6A14411D Send Control FN3 6A14411F Send Control FN...

Page 226: ...ct Reference Guide Keyboard Characters Use these bar codes to send keyboard characters FN3 6A144120 Send Space FN3 6A144121 Send FN3 6A144123 Send FN3 6A144122 Send FN3 6A144124 Send FN3 6A144125 Send...

Page 227: ...Advanced Data Formatting ADF Keyboard Characters continued FN3 6A144128 Send FN3 6A144129 Send FN3 6A14412B Send FN3 6A14412A Send FN3 6A14412C Send FN3 6A14412D Send FN3 6A14412F Send FN3 6A14412E S...

Page 228: ...Scanner Product Reference Guide Keyboard Characters continued FN3 6A144130 Send 0 FN3 6A144131 Send 1 FN3 6A144133 Send 3 FN3 6A144132 Send 2 FN3 6A144134 Send 4 FN3 6A144135 Send 5 FN3 6A144137 Send...

Page 229: ...dvanced Data Formatting ADF Keyboard Characters continued FN3 6A144138 Send 8 FN3 6A144139 Send 9 FN3 6A14413B Send FN3 6A14413A Send FN3 6A14413C Send FN3 6A14413D Send FN3 6A14413F Send FN3 6A14413E...

Page 230: ...O Scanner Product Reference Guide Keyboard Characters continued FN3 6A144140 Send FN3 6A144141 Send A FN3 6A144143 Send C FN3 6A144142 Send B FN3 6A144144 Send D FN3 6A144145 Send E FN3 6A144147 Send...

Page 231: ...d Data Formatting ADF Keyboard Characters continued FN3 6A144148 Send H FN3 6A144149 Send I FN3 6A14414B Send K FN3 6A14414A Send J FN3 6A14414C Send L FN3 6A14414D Send M FN3 6A14414F Send O FN3 6A14...

Page 232: ...Scanner Product Reference Guide Keyboard Characters continued FN3 6A144150 Send P FN3 6A144151 Send Q FN3 6A144153 Send S FN3 6A144152 Send R FN3 6A144154 Send T FN3 6A144155 Send U FN3 6A144157 Send...

Page 233: ...anced Data Formatting ADF Keyboard Characters continued FN3 6A144158 Send X FN3 6A144159 Send Y FN3 6A14415B Send FN3 6A14415A Send Z FN3 6A14415C Send FN3 6A14415D Send FN3 6A14415F Send _ FN3 6A1441...

Page 234: ...O Scanner Product Reference Guide Keyboard Characters continued FN3 6A144160 Send FN3 6A144161 Send a FN3 6A144163 Send c FN3 6A144162 Send b FN3 6A144164 Send d FN3 6A144165 Send e FN3 6A144167 Send...

Page 235: ...d Data Formatting ADF Keyboard Characters continued FN3 6A144168 Send h FN3 6A144169 Send i FN3 6A14416B Send k FN3 6A14416A Send j FN3 6A14416C Send l FN3 6A14416D Send m FN3 6A14416F Send o FN3 6A14...

Page 236: ...Scanner Product Reference Guide Keyboard Characters continued FN3 6A144170 Send p FN3 6A144171 Send q FN3 6A144173 Send s FN3 6A144172 Send r FN3 6A144174 Send t FN3 6A144175 Send u FN3 6A144177 Send...

Page 237: ...3 65 Advanced Data Formatting ADF Keyboard Characters continued FN3 6A144178 Send x FN3 6A144179 Send y FN3 6A14417B Send FN3 6A14417A Send z FN3 6A14417C Send FN3 6A14417D Send FN3 6A14417E Send...

Page 238: ...Send ALT Characters Use these bar codes to send ALT characters FN3 6A144240 Send ALT 2 FN3 6A144241 Send ALT A FN3 6A144243 Send ALT C FN3 6A144242 Send ALT B FN3 6A144244 Send ALT D FN3 6A144245 Send...

Page 239: ...g ADF Send ALT Characters continued FN3 6A144248 Send ALT H FN3 6A144249 Send ALT I FN3 6A14424B Send ALT K FN3 6A14424A Send ALT J FN3 6A14424C Send ALT L FN3 6A14424D Send ALT M FN3 6A14424F Send AL...

Page 240: ...Reference Guide Send ALT Characters continued FN3 6A144250 Send ALT P FN3 6A144251 Send ALT Q FN3 6A144253 Send ALT S FN3 6A144252 Send ALT R FN3 6A144254 Send ALT T FN3 6A144255 Send ALT U S FN3 6A14...

Page 241: ...tting ADF Send ALT Characters continued FN3 6A144258 Send ALT X FN3 6A144259 Send ALT Y FN3 6A14425B Send ALT FN3 6A14425A Send ALT Z FN3 6A14425C Send ALT FN3 6A14425D Send ALT FN3 6A14425F Send ALT...

Page 242: ...STD FZY PRO Scanner Product Reference Guide Send Command Characters FN3 6A144301 Send PA 1 FN3 6A144302 Send PA 2 FN3 6A144304 Send CMD 2 FN3 6A144303 Send CMD 1 FN3 6A144305 Send CMD 3 FN3 6A144306...

Page 243: ...dvanced Data Formatting ADF Send Command Characters continued FN3 6A144309 Send CMD 7 FN3 6A14430A Send CMD 8 FN3 6A14430C Send CMD 10 FN3 6A14430B Send CMD 9 FN3 6A144307 Send CMD 5 FN3 6A144308 Send...

Page 244: ...llet Character FN3 6A144312 Send 1 2 Character FN3 6A144314 Send Section Character FN3 6A144313 Send Paragraph Character FN3 6A144315 Send Vertical Character FN3 6A14430F Send Bomb Character FN3 6A144...

Page 245: ...N3 6A14462A Send Keypad FN3 6A14462B Send Keypad FN3 6A14462E Send Keypad FN3 6A14462D Send Keypad FN3 6A14462F Send Keypad FN3 6A144630 Send Keypad 0 FN3 6A144632 Send Keypad 2 FN3 6A144631 Send Keyp...

Page 246: ...ence Guide Send Keypad Characters continued FN3 6A144635 Send Keypad 5 FN3 6A144636 Send Keypad 6 FN3 6A144638 Send Keypad 8 FN3 6A144637 Send Keypad 7 FN3 6A144639 Send Keypad 9 FN3 6A14463A Send Key...

Page 247: ...d Break Key FN3 6A144702 Send Delete Key FN3 6A144704 Send End Key FN3 6A144703 Send Page Up Key FN3 6A144705 Send Page Down Key FN3 6A144706 Send Pause Key FN3 6A144708 Send Backspace Key FN3 6A14470...

Page 248: ...ued FN3 6A14470B Send Insert Key FN3 6A14470D Send Enter Key FN3 6A14470F Send Up Arrow Key FN3 6A144711 Send Left Arrow Key FN3 6A144713 Send Back Tab Character FN3 6A14470C Send Home Key FN3 6A14470...

Page 249: ...FN3 6A144501 Send F1 Key FN3 6A144502 Send F2 Key FN3 6A144504 Send F4 Key FN3 6A144503 Send F3 Key FN3 6A144505 Send F5 Key FN3 6A144506 Send F6 Key FN3 6A144508 Send F8 Key FN3 6A144507 Send F7 Key...

Page 250: ...s continued FN3 6A14450B Send F11 Key FN3 6A14450C Send F12 Key FN3 6A14450E Send F14 Key FN3 6A14450D Send F13 Key FN3 6A14450F Send F15 Key FN3 6A144510 Send F16 Key FN3 6A144512 Send F18 Key FN3 6A...

Page 251: ...d FN3 6A144515 Send F21 Key FN3 6A144516 Send F22 Key FN3 6A144518 Send F24 Key FN3 6A144517 Send F23 Key FN3 6A144519 Send F25 Key FN3 6A14451A Send F26 Key FN3 6A14451C Send F28 Key FN3 6A14451B Sen...

Page 252: ...s continued FN3 6A144401 Send PF1 Key FN3 6A144402 Send PF2 Key FN3 6A144404 Send PF4 Key FN3 6A144403 Send PF3 Key FN3 6A144405 Send PF5 Key FN3 6A144406 Send PF6 Key FN3 6A144408 Send PF8 Key FN3 6A...

Page 253: ...6A14440B Send PF11 Key FN3 6A14440C Send PF12 Key FN3 6A14440E Send PF14 Key FN3 6A14440D Send PF13 Key FN3 6A14440F Send PF15 Key FN3 6A144410 Send PF16 Key FN3 6A144412 Send PF18 Key FN3 6A144411 S...

Page 254: ...tinued FN3 6A144415 Send PF21 Key FN3 6A144416 Send PF22 Key FN3 6A144418 Send PF24 Key FN3 6A144417 Send PF23 Key FN3 6A144419 Send PF25 Key FN3 6A14441A Send PF26 Key FN3 6A14441C Send PF28 Key FN3...

Page 255: ...ule sets on and off within a rule FN3 6A13911 Turn On Rule Set 1 FN3 6A13921 Turn On Rule Set 2 FN3 6A13941 Turn On Rule Set 4 FN3 6A13931 Turn On Rule Set 3 FN3 6A13910 Turn Off Rule Set 1 FN3 6A1392...

Page 256: ...3 84 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard FN3 B20 Space FN3 B23 FN3 B25 FN3 B24 FN3 B2A FN3 B2B FN3 B2E FN3 B2D...

Page 257: ...3 85 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B22 FN3 B26 FN3 B28 FN3 B27 FN3 B29 FN3 B3A FN3 B21 FN3 B2F...

Page 258: ...3 86 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued FN3 B3C FN3 B3B FN3 B3E FN3 B3D FN3 B3F FN3 B40...

Page 259: ...3 87 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B5C FN3 B5B FN3 B5D FN3 B5E FN3 B60 FN3 B5F _...

Page 260: ...D FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued Bar codes on this page should not be confused with those on the numeric keypad FN3 B30 0 FN3 B31 1 FN3 B33 3 FN3 B32 2 FN3 B34...

Page 261: ...3 89 Advanced Data Formatting ADF Alphanumeric Keyboard continued Bar codes on this page should not be confused with those on the numeric keypad FN3 B37 7 FN3 B36 6 FN3 B39 9 FN3 B38 8...

Page 262: ...3 90 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued FN3 B41 A FN3 B42 B FN3 B44 D FN3 B43 C FN3 B45 E FN3 B46 F FN3 B48 H FN3 B47 G...

Page 263: ...3 91 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B4B K FN3 B4C L FN3 B4E N FN3 B4D M FN3 B4A J FN3 B49 I FN3 B4F O FN3 B50 P...

Page 264: ...3 92 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued FN3 B52 R FN3 B51 Q FN3 B54 T FN3 B53 S FN3 B55 U FN3 B56 V...

Page 265: ...3 93 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B59 Y FN3 B5A Z FN3 B End Of Message FN3 B Cancel FN3 B58 X FN3 B57 W...

Page 266: ...3 94 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued FN3 B61 a FN3 B62 b FN3 B64 d FN3 B63 c FN3 B65 e FN3 B66 f FN3 B68 h FN3 B67 g...

Page 267: ...3 95 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B6B k FN3 B6C l FN3 B6E n FN3 B6D m FN3 B6F o FN3 B70 p FN3 B6A j FN3 B69 i...

Page 268: ...3 96 P 300 STD FZY PRO Scanner Product Reference Guide Alphanumeric Keyboard continued FN3 B72 r FN3 B71 q FN3 B74 t FN3 B73 s FN3 B75 u FN3 B76 v FN3 B78 x FN3 B77 w...

Page 269: ...3 97 Advanced Data Formatting ADF Alphanumeric Keyboard continued FN3 B79 y FN3 B7A z FN3 B7C FN3 B7B FN3 B7E FN3 B7D...

Page 270: ...3 98 P 300 STD FZY PRO Scanner Product Reference Guide...

Page 271: ...nance Cleaning the scanner exit window is the only maintenance required Do not allow any abrasive material to touch the window Remove any dirt particles with a damp cloth Wipe the window using a damp...

Page 272: ...is programmed to read the type of bar code you are scanning Check for loose cable connections Check the symbol to make sure it is not defaced Try scanning test symbols of the same bar code type Symbo...

Page 273: ...character When AIM symbology identifiers are transmitted the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines For example c1 indicates a UCC EAN 12...

Page 274: ...ad as ABCD29E FNC1FNC1ABCDFNC1E are read as ABCD29E ABCDFNC1E cannot be read ABCDE cannot be read Enable Disable Read only symbols without leading FNC 1 Examples FNC1ABCDFNC1E cannot be read AFNC1BCDF...

Page 275: ...g Character ASCII 93 c Code Character see Table A 2 m Modifier Character see Table A 3 Table A 2 AIM Code Identifiers Code Identifiers Code Type A Code 39 C Code 128 E UPC EAN F Codabar G Code 93 H Co...

Page 276: ...d as A7AimId where 7 3 4 Trioptic Code 39 0 No option specified at this time Always transmit 0 Example A Trioptic bar code 412356 is transmitted as X0412356 Code 128 0 Standard data packet no Function...

Page 277: ...tted as M04123 D 2 of 5 0 No options specified at this time Always transmit 0 Example A D 2 of 5 bar code 4123 is transmitted as S04123 UPC EAN 0 Standard packet in full EAN country code format which...

Page 278: ...STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HORIZ TAB 1010 J LF NW LN 1011 K VT 1012 L FF 1013 M CR ENTER 1014 N SO 1015 O SI 1016 P DLE 1017 Q DC1 1018 R DC2 1019...

Page 279: ...O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N Prefix Suf Full ASCII Code ASCII fix Value 39 Encode Char Character 10...

Page 280: ...A 8 P 300STD FZY PRO Scanner Product Reference Guide...

Page 281: ...fix suffix keystroke parameters and are used only with scanners that support data formatting To program the prefix suffix values see the bar codes on page 2 96 Figure B 1 IBM PC XT Keyboard 5001 5002...

Page 282: ...Keyboard 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7009 7008 7013 7012 7004 7011 7003 7002 7014 7019 7009 7013 7017 7004 7016 7002 7008 7014 7018 7015 7005 7011 7012 7003 6042 6047 6058 6045 5...

Page 283: ...8 5019 5001 5017 7013 5011 7013 if double key 1048 if double key 1048 5012 5009 5007 5008 5010 5002 5003 5004 5005 5006 1046 1045 5014 1043 5013 5015 5016 5018 5019 1086 1087 1088 1089 1090 5001 1066...

Page 284: ...B 4 P 300STD FZY PRO Scanner Product Reference Guide...

Page 285: ...ter Set ASCII Value Full ASCII Code 39 Encode Char Keystroke 1000 U CTRL 2 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H 1009 I CTRL I...

Page 286: ...Q 1018 R CTRL R 1019 S CTRL S 1020 T CTRL T 1021 U CTRL U 1022 V CTRL V 1023 W CTRL W 1024 X CTRL X 1025 Y CTRL Y 1026 Z CTRL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Spac...

Page 287: ...J 1043 K 1044 L 1045 1046 1047 1048 0 0 1047 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1055 7 7 1056 8 8 1057 9 9 1058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C Tab...

Page 288: ...69 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091...

Page 289: ...8 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120...

Page 290: ...1127 Undefined 1128 ALT Keys Keystroke 2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 A...

Page 291: ...W 2088 ALT X 2089 ALT Y 2090 ALT Z 2091 ALT 2092 ALT 2093 ALT 2094 ALT 6 2095 ALT Misc Key Keystroke 3001 PA 1 3002 PA 2 3003 CMD 1 3004 CMD 2 3005 CMD 3 3006 CMD 4 3007 CMD 5 3008 CMD 6 3009 CMD 7 30...

Page 292: ...3018 1 2 3019 3020 3021 3022 0 00 PF Keys Keystrokes 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 4014 PF 14 4...

Page 293: ...1 PF 21 4022 PF 22 4023 PF 23 4024 PF 24 F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F1...

Page 294: ...21 5022 F22 5023 F23 5024 F24 5025 F25 5026 F26 5027 F27 5028 F28 5029 F29 5030 F30 5031 F31 5032 F32 5033 F33 5034 F34 5035 F35 5036 F36 5037 F37 5038 F38 5039 F39 5040 F40 Numeric Keypad Keystroke 6...

Page 295: ...6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock 6060 00 Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab...

Page 296: ...12 P 300STD FZY PRO Scanner Product Reference Guide 7012 Home 7013 Enter 7014 Escape 7015 Up Arrow 7016 Dn Arrow 7017 Left Arrow 7018 Right Arrow 7019 Back Tab Table C 1 ASCII Character Set Continued...

Page 297: ...SCII Trioptic Code 39 Code 93 Codabar Interleaved 2 of 5 Code 128 EAN 128 Discrete 2 of 5 MSI Plessey and PDF417 Set code length s for any linear code type The P 300FZY and 300PRO can auto discriminat...

Page 298: ...mis operation due to an insufficient power condition Ambient Light Immunity Artificial Lighting Sunlight 450 ft candles 4844 lux 9000 ft candles 96876 lux 8 in 20 cm on low density bar codes Operating...

Page 299: ...one 2 0 4 0 7 0 11 0 22 0 30 0 60 0 80 0 Distance from Front of Scanner 2 0 3 0 5 0 7 5 Mil Width of Field 3 0 80 MRD 31 MRD 10 25 4 20 50 8 30 76 2 40 101 6 50 127 60 152 4 70 177 8 80 203 2 0 0 in c...

Page 300: ...100 character PDF bar code and 15 mil 64 character PDF bar code 1 5 4 0 7 0 12 0 23 0 34 0 65 0 84 0 Distance from Front of Scanner 1 5 3 0 5 0 7 5 Mil Width of Field 2 0 80 MRD 31 MRD 10 25 4 20 50...

Page 301: ...i d t h o f F i e l d Depth of Field 2 0 0 Note Typical performance at 68 F 20 C on high quality symbols 1 5 3 6 9 3 6 9 7 6 15 2 22 8 7 6 15 2 22 8 3 6 9 12 15 18 21 24 0 7 6 15 2 22 8 30 4 38 1 45 7...

Page 302: ...2 D Decode Zone In cm 0 6 6 mil 6 0 10 mil 9 5 0 In cm W i d t h o f F i e l d Depth of Field 3 0 0 Note Typical performance at 68 F 20 C on high quality symbols 1 25 2 4 6 2 4 6 5 0 10 1 15 2 5 0 10...

Page 303: ...D 7 Technical Specifications Pin outs Table D 2 Pin outs Pin P 300 1 Reserved 2 Power 3 Ground 4 Synapse Data 5 Synapse Clock 6 RxD 7 TxD 8 DTR 9 CTS 10 RTS...

Page 304: ...D 8 P 300STD FZY PRO Scanner Product Reference Guide...

Page 305: ...RIMINATION The ability of an interface controller to determine the code type of a scanned bar code After this determination is made the information content can be decoded AVERAGE BAR WIDTH GROWTH Aver...

Page 306: ...e a symbol successfully by reading in complementary opposite directions across bars and spaces BIT Binary digit One bit is the basic unit of binary information Generally eight consecutive bits compose...

Page 307: ...sented CODEWORD In PDF417 a single group of bars and spaces 4 bars and 4 spaces for a total of 17 module widths which represents one or more numbers letters or other symbols CODEWORD PD CODEWORD PERCE...

Page 308: ...resentation of the letters or numbers encoded within a bar code symbol DEPTH OF FIELD The range between minimum and maximum distances at which a scanner can read a symbol with a certain minimum elemen...

Page 309: ...s expensive and provide higher bit densities GUARD BARS The start stop and center delimiting bars of UPC and EAN symbols HOST COMPUTER A computer that serves other terminals in a network providing suc...

Page 310: ...omposition MIL 1 mil 1 thousandth of an inch MINIMUM REFLECTANCE DIFFERENCE MRD The difference in percentage between light reflected from spaces RS and light reflected from bars RB MRD RS RB MISREAD M...

Page 311: ...required for start stop and checking for a given symbol in PDF417 also left and right row indicators and error correction codewords For example a one dimensional symbol requiring start stop and two c...

Page 312: ...T CONTRAST SIGNAL PCS Measurement of the contrast brightness difference between the bars and spaces of a symbol A minimum PCS value is needed for a bar code symbol to be scannable PCS RL RD RL where R...

Page 313: ...n bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol Its three main components are 1 Light source laser or photoelectric cell illuminates a bar code...

Page 314: ...distance between the outside edges of the quiet zones of the first row and the last row SYMBOL LENGTH Length of symbol measured from the beginning of the quiet zone margin adjacent to the start chara...

Page 315: ...inted bars X DIMENSION Width of the narrowest element bar of space in a bar code symbol Y DIMENSION Element height as applied to a two dimensional symbology which must equal or exceed a required minim...

Page 316: ...Glossary 12 P 300 STD FZY PRO Scanner Product Reference Guide...

Page 317: ...numeric keypad 3 23 rule belongs to set 3 24 rules 3 1 rules heirarchy 3 6 send ALT characters 3 66 send command characters 3 70 send control characters 3 49 send function keys 3 77 send keypad chara...

Page 318: ...near code type security level 2 21 MSI Plessey 2 79 MSI plessey check digits 2 82 lengths 2 80 transmit check digit 2 83 NOTIS Editing 2 78 numeric bar codes 2 120 PDF417 enable 2 85 power mode 2 16 R...

Page 319: ...2 of 5 2 5 E EAN 13 2 3 EAN 8 2 3 ECI decoder 2 130 delete character set ECIs 2 129 ECI Decoder 2 8 Enable Disable Codabar 2 74 Enable Disable Code 128 2 46 Enable Disable Code 39 Full ASCII 2 56 Ena...

Page 320: ...PDF Transmit Decode Mode Symbols 2 7 Maintenance 4 1 MSI Plessey 2 5 MSI Plessey Check Digit Algorithm 2 5 2 84 MSI Plessey Check Digits 2 5 2 82 N National Keyboard Type 2 7 NIXDORF Mode A Mode B 2 1...

Page 321: ...83 Transmit UPC A UPC E Check Digit 2 35 Transmit UPC E1 Check Digit 2 41 Transmit No Read Message 2 19 Trigger Mode 2 17 UPC A Preamble 2 36 UPC E Preamble 2 37 UPC EAN Security Level 2 42 Wand Conve...

Page 322: ...gth s for MSI Plessey 2 5 Set Up 1 2 Connecting Power 1 3 Connecting to Host 1 4 Installing the Cable 1 2 Switching Cables 1 3 slab raster 1 8 1 9 1 10 smart raster 1 8 1 9 Software Handshaking 2 6 2...

Page 323: ...acking 1 1 UPC A 2 2 UPC A Preamble 2 3 2 36 UPC E 2 3 UPC E Preamble 2 3 2 37 UPC E1 2 3 UPC E1 Preamble 2 3 UPC EAN Security Level 2 42 UPC EAN Security Levels 2 3 User Documentation 1 2 V Variable...

Page 324: ...Index 8 P 300STD FZY PRO Scanner Product Reference Guide...

Page 325: ..._____ please include revision level How familiar were you with this product before using this manual Did this manual meet your needs If not please explain ________________ ____________________________...

Reviews: