7-16
MS-804FZY and MS-904HS Integration Guide
Timeout Between Decodes
Timeout Between Decodes, Same Symbol
Parameter # 89h
When in Continuous triggering mode, this parameter sets the minimum duration of not
decoding data before the scanner decodes a second bar code identical to one just
decoded. This reduces the risk of accidently scanning the same symbol twice. It is
programmable in 0.1 second increments from 0.0 to 9.9 seconds. The recommended
interval is 0.6 seconds.
Timeout Between Decodes, Different Symbol
Parameter # 90h
This option sets the minimum duration of not decoding data before the scanner decodes a
second (different) bar code. This is used in continuous-on mode to prevent the beeper from
beeping when a different symbol appears in the scanner’s field of view before the timeout
period between decodes expires. This is programmable in 0.1 second increments from 0.0
to 9.9 seconds. The recommended value is 0.0 seconds.
Select the timeouts between decodes for the same or different symbols.
1. Scan the option bar code you wish to set.
2. Scan two numeric bar codes beginning on
which correspond to the
desired interval, in 0.1 second increments.
Summary of Contents for MiniScan MS-804FZY
Page 1: ...MiniScan MS 804FZY and MS 904HS Integration Guide...
Page 2: ......
Page 3: ...MiniScan MS 804FZY and MS 904HS Integration Guide 72 58197 01 Revision A September 2003...
Page 10: ...viii MS 804FZY and MS 904HS Integration Guide...
Page 16: ...xiv MS 804FZY and MS 904HS Integration Guide...
Page 58: ...5 4 MS 804FZY and MS 904HS Integration Guide...
Page 166: ...7 106 MS 804FZY and MS 904HS Integration Guide Numeric Bar Codes continued 4 5 6 7...
Page 168: ...7 108 MS 804FZY and MS 904HS Integration Guide...
Page 172: ...9 2 MS 804FZY and MS 904HS Integration Guide...
Page 182: ...Index 4 MS 804FZY and MS 904HS Integration Guide...
Page 183: ......