Cause 2: Power is not supplied
1.
Connect the SIEM 9700 Series appliance AC power cables to another
external power source.
2.
Check the status of the power running/alarm indicator.
•
If the power on/alarm indicator is flashing green, power on the
device. If the system power indicator is on, the fault is removed.
•
If the power on/alarm indicator is amber, a power module alarm
occurs on a power module.
•
If the power on/alarm indicator is still off, contact technical
support.
3.
If the power is still off, contact technical support.
Memory capacity has decreased
Symptom
The memory capacity detected during BIOS booting is less than the actual memory
capacity.
Procedures
Contact technical support.
Disk status LED is red
The SIEM 9700 Series appliance contains eight disk bays. Each bay can hold one
disk module, which includes one disk carrier and one disk drive. The carrier and its
disk drive are labeled 0 to 7, from left to right. All drives are hot-swappable. Slot 7 is
reserved as a spare. Slots 0 to 6 are intended for use with RAID cards, forming a
RAID 5 group.
Each module has two LEDs, one red and one green.
The green LED flashes when disk drive activity occurs and is solid green when
no activity occurs.
A red LED indicates a fault.